Pelco C2622M manual Installation, Package Contents

Page 10

Installation

PACKAGE CONTENTS

The following items are supplied:

1FX82051 module

1Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output

1Wall clip with two 4-40 x 0.250-inch Phillips pan head screws with lock washers (for attachment of single module to wall)

1FX82051 Unmanaged Ethernet Switch Installation manual

SETTING 10BASE-T/100BASE-TX PORT MODES OF OPERATION

NOTE: As a matter of convenience, it is recommended that you verify the modes of operation for each 10BASE-T/100BASE-TX port and then change the mode settings—if necessary—before mounting the FX82051 module into a rack or onto a wall.

The FX82051 module provides various configuration options that allow you to select the desired modes of operation for each 10BASE-T/100BASE-TX port (ports 1-5). You can select the desired modes of operation by means of a TX Mode switch that is provided on the bottom of the module for each port (refer to Figure 4).

TX MODE SWITCHES - PORTS 1-5

TX Mode

0. Auto Neg / Dis FC

1. 100 FD / Dis FC

2. 100 HD / Dis FC

3. 10 FD / Dis FC

4. 10 HD / Dis FC

5. Auto Neg / En FC

6. 100 FD / En FC

7. 100 HD / En FC

8. 10 FD / En FC

9. 10 HD / En FC

Figure 4. TX Mode Switches for 10BASE-T/100BASE-TX Ports 1-5

10

C2622M (2/07)

Image 10
Contents Ethernet Switch List of Illustrations ContentsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionMultimode Models ModelsFX82051 module consists of the following series of models Single-Mode Models*†Front Panel Power LED Pelco badge100BASE-FX Status LED 10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectors Rear PanelInstallation Package ContentsAutonegotiation is enabled by default Flow control is disabled by defaultFlow control default setting Table A. TX Mode Switch Settings10BASE-T/100BASE-TX Modes of Operation Mounting Mounting the FX82051 Module Into a RackMounting the FX82051 Module Using the Wall Clip 10BASE-T/100BASE-TX connections ConnectionsFiber connections Fiber Port Connections in Point-to-Point Application Troubleshooting Meaning Possible Cause Corrective Action Optic Fault LED Data is being Desired, refer to Setting Transmitted or Table C. Troubleshooting with Rear-Panel IndicatorsDesired, refer to Setting AmberMeaning Possible Cause Corrective Action If half-duplex mode is Duplex modeDuplex mode Duplex link Amber Port is set to If 10BASE-T full-duplexReplace cable if it is Green Port is set to If 100BASE-TX full-duplexFlashing green Port is set to Normal or excessive Use Cat5e or higherTable C. Troubleshooting with Rear-Panel Indicators Specifications Duplex/collision and speedOptical Maximum Laser FX82051SSTR-2Appendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsProduct Warranty and Return Information ISO9001