Pelco C2622M manual Meaning Possible Cause Corrective Action Optic Fault LED

Page 18

Table B. Troubleshooting with Front-Panel Indicators (Continued)

Indicator Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

 

 

Optic Fault LED (

)

 

 

 

 

 

 

Green

The optical signal is

 

No action required.

 

being received and

 

 

 

 

laser is operating

 

 

 

 

properly.

 

 

 

 

 

 

 

Red

The optical signal is

Remote module is not

Check power connections.

 

not being received.

powered on.

 

Replace power supply if

 

 

 

 

necessary.

 

 

 

 

 

 

Fiber optic cable is not

Check fiber optic

 

 

connected.

 

connections.

 

 

 

 

 

 

Fiber optic cable connectors

Clean, polish, or replace fiber

 

 

are dirty or are damaged.

optic cable connectors as

 

 

 

 

necessary.

 

 

 

 

 

 

 

Fiber optic cable is

 

Replace cable.

 

 

defective.

 

 

 

 

 

 

 

 

Optical dB losses in the

Check for problems with the

 

 

fiber optic installation

fiber optic installation, for

 

 

exceed the optical power

example, excessive dB losses

 

 

budget specification stated

in connectors, splices, patch

 

 

in Specifications on

 

panels, cables, and so on.

 

 

page 24.

 

 

 

 

 

 

 

 

Optical dB losses in the

Contact Product Support at

 

 

fiber optic installation meet

1-559-292-1981.

 

 

the optical power budget

 

 

 

specification stated in

 

 

 

Specifications on page 24;

 

 

 

however, a module is

 

 

 

defective.

 

 

 

 

 

 

Flashing red

Laser has shut down.

Module is operating in

Ensure that module operates

 

 

extreme environmental

according to operating

 

 

conditions; for example,

conditions stated in

 

 

operating temperature is

Specifications on page 24,

 

 

below or above recom-

and then cycle the power.

 

 

mended range as stated in

If problem persists, contact

 

 

Specifications on page 24.

Product Support at

 

 

 

 

1-559-292-1981.

 

 

 

 

 

 

Laser has reached end of

Cycle the power. If problem

 

 

life.

 

persists, contact Product

 

 

 

 

Support at 1-559-292-1981.

 

 

 

 

 

 

 

 

 

(Continued on next page)

18

C2622M (2/07)

Image 18
Contents Ethernet Switch Contents List of IllustrationsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionMultimode Models ModelsFX82051 module consists of the following series of models Single-Mode Models*†Power LED Pelco badge Front Panel100BASE-FX Status LED 10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectors Rear PanelInstallation Package ContentsAutonegotiation is enabled by default Flow control is disabled by defaultTable A. TX Mode Switch Settings Flow control default setting10BASE-T/100BASE-TX Modes of Operation Mounting Mounting the FX82051 Module Into a RackMounting the FX82051 Module Using the Wall Clip Connections 10BASE-T/100BASE-TX connectionsFiber connections Fiber Port Connections in Point-to-Point Application Troubleshooting Meaning Possible Cause Corrective Action Optic Fault LED Data is being Desired, refer to Setting Transmitted or Table C. Troubleshooting with Rear-Panel IndicatorsDesired, refer to Setting AmberMeaning Possible Cause Corrective Action If half-duplex mode is Duplex modeDuplex mode Duplex link Amber Port is set to If 10BASE-T full-duplexReplace cable if it is Green Port is set to If 100BASE-TX full-duplexFlashing green Port is set to Normal or excessive Use Cat5e or higherTable C. Troubleshooting with Rear-Panel Indicators Specifications Duplex/collision and speedOptical Maximum Laser FX82051SSTR-2Appendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsProduct Warranty and Return Information ISO9001