Pelco C2622M manual Connections, 10BASE-T/100BASE-TX connections, Fiber connections

Page 15

CONNECTIONS

Connections to the FX82051 module are made on the rear panel of the module (refer to Figure 6).

POWER/ALARM

CONNECTION FOR

RACK-MOUNTED MODULE

POWER CONNECTION FOR

STAND-ALONE MODULE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

FIBER OPTIC CABLES

Figure 6. FX82051 Module Connections

As illustrated in Figure 6, FX82051 connections consist of the following:

Power connection

NOTES:

A 12 VDC or 24 VAC power supply can be used to power the module when used as a stand-alone unit. A 12 VDC power supply is provided. If a 24 VAC power supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and rated as 24 VAC, 0.50 A (minimum output).

In extreme temperature conditions, it is recommended that an industrial-rated outdoor power supply such as the Pelco WCS1-4 power supply be used.

10BASE-T/100BASE-TX connections

NOTES:

Use Category 5e or a higher category of cable to connect to a 10BASE-T/100BASE-TX port. Cable length must not exceed 328 feet (100 meters).

The 10BASE-T/100BASE-TX ports are auto MDI/MDI-X ports; therefore, either a straight-through or crossover cable can be used. The ports automatically detect the cable type that is used. Refer to Appendix. RJ-45 Connector Pinouts on page 26 for RJ-45 MDI/MDI-X pinout information.

Fiber connections

NOTE: Refer to Figure 7 for an illustration of fiber port connections in a point-to-point application.

C2622M (2/07)

15

Image 15
Contents Ethernet Switch Contents List of IllustrationsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewSingle-Mode Models*† ModelsFX82051 module consists of the following series of models Multimode ModelsPower LED Pelco badge Front Panel100BASE-FX Status LED Rear Panel 10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectorsPackage Contents InstallationFlow control is disabled by default Autonegotiation is enabled by defaultTable A. TX Mode Switch Settings Flow control default setting10BASE-T/100BASE-TX Modes of Operation Mounting the FX82051 Module Into a Rack MountingMounting the FX82051 Module Using the Wall Clip Connections 10BASE-T/100BASE-TX connectionsFiber connections Fiber Port Connections in Point-to-Point Application Troubleshooting Meaning Possible Cause Corrective Action Optic Fault LED Amber Table C. Troubleshooting with Rear-Panel IndicatorsDesired, refer to Setting Data is being Desired, refer to Setting Transmitted orMeaning Possible Cause Corrective Action Amber Port is set to If 10BASE-T full-duplex Duplex modeDuplex mode Duplex link If half-duplex mode isUse Cat5e or higher Green Port is set to If 100BASE-TX full-duplexFlashing green Port is set to Normal or excessive Replace cable if it isTable C. Troubleshooting with Rear-Panel Indicators Duplex/collision and speed SpecificationsFX82051SSTR-2 Optical Maximum LaserIllustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsProduct Warranty and Return Information ISO9001