Pelco C2622M manual Mounting the FX82051 Module Into a Rack

Page 13

MOUNTING

The FX82051 module can be mounted into a rack or can be used as a stand-alone module. As a stand- alone module, the unit can be placed on a desktop or can be mounted to a wall.

NOTE: As a matter of convenience, it is recommended that you set the modes of operation for each 10BASE-T/100BASE-TX port—if required—before mounting the FX82051 module into a rack or onto

awall. For information about setting the modes of operation, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 10.

MOUNTING THE FX82051 MODULE INTO A RACK

The FX82051 module can be installed into an RK5000 Series rack mount chassis, which can be mounted into an industry-standard 19-inch (48.26 cm) equipment rack. The RK5000 Series rack mount chassis includes the following models:

RK5000PS-3U and RK5000-3U:Designed to accommodate fiber optic modules as follows:

The RK5000PS-3U rack mount chassis provides 12 single-width module slots and a power supply.

The RK5000-3U rack mount chassis provides 14 single-width module slots (a power supply is not included). Power to the modules can be supplied using the optional external power supply (EPS5000-120).

For additional information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount Chassis Installation manual.

RK5000PS-5U:Designed to accommodate Enduramodules but can also accommodate fiber optic modules with the use of the appropriate adapter kit. The RK5002-1UEXP adapter kit is required for installation of the FX82051 module into the RK5000PS-5U chassis.

For information about the RK5000PS-5U chassis, refer to the RK5000PS-5U Rack Mount Chassis Installation manual.

NOTE: The FX82051 module is a double-width fiber optic module that occupies two slots in the RK5000PS-3U, RK5000-3U, and RK5000PS-5U chassis.

MOUNTING THE FX82051 MODULE TO A WALL

The FX82051 module can be mounted to a wall in the following ways:

Using the supplied wall clip for attachment of a single module to a wall. For installation instructions, refer to Mounting the FX82051 Module Using the Wall Clip on page 14.

Using the optional WM5002 wall mount kits, which are designed for mounting of double- width fiber optic modules. The WM5002-3U base kit allows mounting of a single module to a wall. The WM5002-3UEXP expansion kit allows mounting of an additional module. It is recommended that a maximum of one expansion kit be used with the base kit, allowing a maximum of two double-width modules to be mounted to a wall.

NOTE: The WM5002 wall mount kits can be used with the WM5001 wall mount kits, which are designed for mounting of single-width fiber optic modules. If mounting a mix of single-width and double-width modules is desired, it is recommended that a maximum of two single-width modules and one double-width module be mounted in combination with one another.

For mounting instructions using the wall mount kits, refer to the WM5000 Series Wall Mount Kit Installation manual.

C2622M (2/07)

13

Image 13
Contents Ethernet Switch List of Illustrations ContentsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewFX82051 module consists of the following series of models ModelsMultimode Models Single-Mode Models*†Front Panel Power LED Pelco badge100BASE-FX Status LED Rear Panel 10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectorsPackage Contents InstallationFlow control is disabled by default Autonegotiation is enabled by defaultFlow control default setting Table A. TX Mode Switch Settings10BASE-T/100BASE-TX Modes of Operation Mounting the FX82051 Module Into a Rack MountingMounting the FX82051 Module Using the Wall Clip 10BASE-T/100BASE-TX connections ConnectionsFiber connections Fiber Port Connections in Point-to-Point Application Troubleshooting Meaning Possible Cause Corrective Action Optic Fault LED Desired, refer to Setting Table C. Troubleshooting with Rear-Panel IndicatorsData is being Desired, refer to Setting Transmitted or AmberMeaning Possible Cause Corrective Action Duplex mode Duplex link Duplex modeIf half-duplex mode is Amber Port is set to If 10BASE-T full-duplexFlashing green Port is set to Normal or excessive Green Port is set to If 100BASE-TX full-duplexReplace cable if it is Use Cat5e or higherTable C. Troubleshooting with Rear-Panel Indicators Duplex/collision and speed SpecificationsFX82051SSTR-2 Optical Maximum LaserIllustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsProduct Warranty and Return Information ISO9001