Schneider Electric 3000, 5000 user manual Introduction, Unpacking, Specifications, Installation

Page 3
Introduction

Introduction

The APCby Schneider Electric Smart-UPSRT is a high-performance, uninterruptible power supply (UPS) that provides protection for electronic equipment from utility power blackouts, brownouts, sags and surges. The UPS filters small utility line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from utility line power. The UPS provides continuous power from the internal battery until utility power returns to safe levels or the battery is fully discharged.

INSTALLATION

Read the Safety Guide before installing the UPS.

Unpacking

Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly.

Check the package contents:

„UPS (with battery modules disconnected)

„Front bezel

„Literature kit containing:

„Product documentation, Safety Guide, and Warranty Information

„Smart-UPS RT User Manuals CD

„Software CD

„Serial cable

„3000 VA XLI models: three output power cords, two input power cords

„5000/6000 VA XLI models: six output power cords, Network Management Card documentation

Specifications

TEMPERATURE

 

This unit is designed for indoor use

OPERATING

32° to 104° F (0° to 40° C)

only. Select a location sturdy enough to

STORAGE

5° to 113° F (-15° to 45° C) charge the UPS

handle the weight.

 

battery every six months

Do not operate the UPS where there is

MAXIMUM

 

excessive dust or the temperature and

ELEVATION

 

humidity are outside the specified limits.

OPERATING

10,000 ft (3,000 m)

Ensure that the air vents on the front

STORAGE

50,000 ft (15,240 m)

and rear of the UPS are not blocked.

 

 

 

 

 

HUMIDITY

0 to 95% relative humidity

 

 

 

 

 

 

 

 

WEIGHT

 

 

 

 

UPS

120 lbs (55 kg)

 

 

 

UPS WITH

140 lbs (64 kg)

 

 

 

PACKAGING

 

 

 

 

.

 

1

 

 

Image 3
Contents User Manual Uninterruptible Power Supply3000/5000/6000 VA 200-240 Vac Tower/Rack Mount 3U Smart-UPS RTPage Introduction SpecificationsINSTALLATION Read the Safety Guide before installing the UPSWiring and Connecting the UPS CONNECTING THE BATTERY MODULES AND ATTACHING THE FRONT BEZEL Use only interface kits supplied or approved by APC connectorWhen connecting grounding cable, disconnect the unit from the utility power outlet2. Avoid using extension cords OPERATION On Battery Operation The UPS starts a self-test as part of this procedure. The self-testdoes not affect the voltage display FACTORY USER CONFIGURABLE ITEMSDEFAULT FUNCTIONAdhere to National and local electrical codes when wiring the EPO Services 9 bits per second 9 data - bits 9 parity - none 9 stop bit9 flow control - none 5000/6000 VA models X YZ \ Replacing the Battery ModuleMAINTENANCE AND TRANSPORT Be careful during battery replacement, the battery modules are heavyDisconnecting the Battery for Transport The batterys may remain in the UPSREPLACING BATTERY MODULES CAUSE TROUBLESHOOTING, SERVICE, AND WARRANTY INFORMATIONPROBLEM AND POSSIBLE SOLUTIONUPS OPERATES ON BATTERY ALTHOUGH NORMAL LINE VOLTAGE EXISTS FAULT AND OVERLOAD LEDS ILLUMINATE, UPS EMITS A SUSTAINED ALARM TONEFAULT LED ILLUMINATES REPLACE BATTERY LED ILLUMINATESLimited Warranty ServiceAPC Worldwide Customer Support Radio Frequency WarningsREGULATORY