Schneider Electric 5000, 3000 Use only interface kits supplied or approved by APC, connector

Page 6
serial com

BASIC CONNECTORS

 

 

 

 

 

 

 

Power management software and interface kits can be used with the UPS.

serial com

 

 

Use only interface kits supplied or approved by APC.

 

 

Any other serial interface cable will be incompatible with the UPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connector.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual bypass enables the user to manually put connected equipment into

 

 

 

 

 

 

 

 

 

 

 

 

bypass mode.

normal bypass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Emergency Power Off terminal allows the user to connect the UPS to the

 

 

 

 

 

 

 

 

 

 

 

 

central EPO system.

EPO terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The UPS features a transient voltage surge-suppression (TVSS) screw for

 

 

 

 

 

 

 

 

 

 

 

 

connecting the ground lead on surge suppression devices such as telephone

TVSS screw

 

 

and network line protectors.

 

 

When connecting grounding cable, disconnect the unit from the utility

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power outlet.

 

 

 

 

 

 

 

Optional external battery packs provide extended runtime during power

 

 

 

 

 

 

 

 

 

 

 

 

 

outages. These units support up to ten external battery packs.

external battery

 

 

 

See the APC Web site, www.apc.com for the information on the external

pack connector

 

 

battery pack, SURT192XLBP.

 

 

 

 

5000/6000 VA

 

 

 

XLI models

 

 

 

 

 

 

 

 

 

 

 

output circuit breakers

3000/5000/6000 VA XLJ/XLT/XLTW models

output circuit breaker

4

Image 6
Contents Smart-UPS RT Uninterruptible Power Supply3000/5000/6000 VA 200-240 Vac Tower/Rack Mount 3U User ManualPage Read the Safety Guide before installing the UPS SpecificationsINSTALLATION IntroductionWiring and Connecting the UPS CONNECTING THE BATTERY MODULES AND ATTACHING THE FRONT BEZEL power outlet connectorWhen connecting grounding cable, disconnect the unit from the utility Use only interface kits supplied or approved by APC2. Avoid using extension cords OPERATION On Battery Operation The UPS starts a self-test as part of this procedure. The self-testdoes not affect the voltage display FUNCTION USER CONFIGURABLE ITEMSDEFAULT FACTORYAdhere to National and local electrical codes when wiring the EPO Services 9 bits per second 9 data - bits 9 parity - none 9 stop bit9 flow control - none 5000/6000 VA models Be careful during battery replacement, the battery modules are heavy Replacing the Battery ModuleMAINTENANCE AND TRANSPORT X YZ \Disconnecting the Battery for Transport The batterys may remain in the UPSREPLACING BATTERY MODULES SOLUTION TROUBLESHOOTING, SERVICE, AND WARRANTY INFORMATIONPROBLEM AND POSSIBLE CAUSEREPLACE BATTERY LED ILLUMINATES FAULT AND OVERLOAD LEDS ILLUMINATE, UPS EMITS A SUSTAINED ALARM TONEFAULT LED ILLUMINATES UPS OPERATES ON BATTERY ALTHOUGH NORMAL LINE VOLTAGE EXISTSService Limited WarrantyAPC Worldwide Customer Support Radio Frequency WarningsREGULATORY