To Power On Main Power Mode

To power on main power for all server components:

a. Verify that the power cord has been connected and that standby power is on.

In standby power mode, the Power/OK LED on the front panel flashes. See FIGURE 1-3.

b. Use a ballpoint pen or other stylus to press and release the recessed Power button on the server front panel.

When main power is applied to the full server, the Power/OK LED next to the Power button lights and remains lit.

Note – The first time the server powers on, the power on self-test (POST) can take up to a minute.

To Power Off Main Power Mode

To power off the server from main power mode, use one of the following two methods:

Graceful shutdown: Use a ballpoint pen or other stylus to press and release the Power button on the front panel. This causes Advanced Configuration and Power Interface (ACPI) enabled operating systems to perform an orderly shutdown of the operating system. Servers not running ACPI-enabled operating systems will shut down to standby power mode immediately.

Emergency shutdown: Press and hold the Power button for four seconds to force main power off and enter standby power mode. When the main power is off, the Power/OK LED on the front panel will begin flashing, indicating that the server is in standby power mode.

Caution – To completely power off the server, you must disconnect the AC power cords from the back panel of the server.

8 Sun Fire X2100 M2 Server Installation Guide • August 2006

Image 12
Contents Sun Fire X2100 M2 Server Installation Guide Please Recycle Contents Configuring the Preinstalled Solaris 10 Operating System Setting Up the Sun Fire X2100 M2 Server Hardware Safety and Compliance InformationPlanning the Installation Process StartPackage Contents Inventory Installing the Server Into a Rack With Optional Slide Rails Connecting the Cables To Connect the CablesPowering On and Powering Off Server Back Panel Label Connector/SlotConfiguration Without adequate cooling mechanisms To Power On Main Power Mode To Power Off Main Power ModeSetup Troubleshooting and Support Troubleshooting the Sun Fire X2100 M2 Server Setup3Troubleshooting Procedures Contacting Support 4System Information Needed for SupportSun Fire X2100 M2 Server Documentation Setting Up the Sun Fire X2100 M2 Server Software About the Embedded LOM Service Processor SoftwareSun Fire X2100 M2 Server Installation Guide August To Configure the Embedded LOM SP Using a Serial Connection Show /SP/AgentInfo Configuring the Embedded LOM SP Using an Ethernet Connection To Configure the Embedded LOM SP Using a Dhcp ServerLog in to your Dhcp server and view its Dhcp log file # ssh -l root To Configure the Embedded LOM SP Using a Static IP Address To Configure Static IP Addresses Using the Web GUIClick the Control button to display the drop-down menu Network Settings Page displays To Configure Static IP Addresses Using the CLI Changing Serial Output to Display the System Information1Serial Terminal Key Remapping Configuring or Installing System Software Additional Preinstalled Software Installing Other Operating Systems and DriversInstallation Worksheet Before You BeginInstallation Worksheet Configuring the Preinstalled Solaris 10 Operating System Installation Worksheet Configuring the Preinstalled Solaris 10 Operating System To Connect to the Server Using a Serial Capture Program onSelect Advanced To Connect to the Server Using a Serial Capture Program To Redirect the Console Output to the Video Port OptionalStart a terminal session to capture the serial port output Accessing Solaris 10 User Documentation Solaris 10 Operating System User InformationDownloading Solaris 10 OS Software Solaris 10 OS TrainingSun Fire X2100 M2 Server Installation Guide August