Note – Do not use the scadm utility while SunVTS™ diagnostics are running. See your SunVTS documentation for more information.
You must be logged in to the system as root to use the scadm utility. The scadm utility uses the following syntax:
#scadm command
The scadm utility sends its output to stdout. You can also use scadm in scripts to manage and configure ALOM from the host system.
For more information about the scadm utility, refer to the following:
■scadm man page
■Advanced Lights Out Manager User’s Guide
▼To View Environmental Information
1.Log in to the ALOM system controller.
2.Use the showenvironment command to display a snapshot of the server’s environmental status.
sc> showenvironment
=============== Environmental Status ===============
System Temperatures (Temperatures in Celsius):
Sensor Status Temp LowHard LowSoft LowWarn HighWarn HighSoft HighHard
C0.P0.T_CORE | OK | 48 | 0 | 97 | 102 | 120 | ||
C1.P0.T_CORE | OK | 53 | 0 | 97 | 102 | 120 | ||
C2.P0.T_CORE | OK | 49 | 0 | 97 | 102 | 120 | ||
C3.P0.T_CORE | OK | 57 | 0 | 97 | 102 | 120 | ||
C0.T_AMB | OK | 28 | 0 | 70 | 82 | 87 | ||
C1.T_AMB | OK | 33 | 0 | 70 | 82 | 87 | ||
C2.T_AMB | OK | 27 | 0 | 70 | 82 | 87 | ||
C3.T_AMB | OK | 28 | 0 | 70 | 82 | 87 | ||
MB.T_AMB | OK | 32 | 0 | 65 | 75 | 85 | ||
... |
|
|
|
|
|
|
|
|