▼To Perform a Mirrored Disk Hot-Plug Operation
1.Verify which hard drive corresponds with which logical device name and physical device name.
See “Physical Disk Slot Numbers, Physical Device Names, and Logical Device Names” on page 57.
Caution – Ensure that the hard drive
2.To confirm a failed disk, type the following command:
#raidctl
For example:
#raidctl
RAID | RAID | RAID | Disk |
Volume | Status | Disk | Status |
c1t1d0 DEGRADED c1t1d0 OK c1t2d0 DEGRADED
This example indicates that the disk mirror has degraded due to a failure in disk c1t2d0.
Note – The logical device names might appear differently on your system, depending on the number and type of
3.Remove the hard drive, as described in the Netra 440 Server Service Manual.
There is no need to issue a software command to bring the drive offline when the drive has failed and the
4.Install a new hard drive, as described in the Netra 440 Server Service Manual. The RAID utility automatically restores the data to the disk.