Paradyne Data Storage, Memory, Saving to Local Files, SMD2000-24T Backup

Page 17

Data Storage

Configuration backup is inherent in the SMD2000-24T. Default parameters remain in place unless changed using the CLI, web management system, or SNMP.

Memory

Parameter configurations are automatically recorded in both Random Access Memory (RAM) and Non-Volatile Random Access Memory (NVRAM).

Data stored only in RAM, such as traffic statistics and link up/down time, will be erased if the SMD2000-24T loses power.

Data stored in NVRAM, such as management and port parameter configurations, will remain intact (even if the SMD2000-24T loses power) unless deliberately cleared or reconfigured.

Saving to Local Files

SMD2000-24T management and port configurations can be uploaded to a local file on your PC or local network via the Trivial File Transfer Protocol (TFTP) GET command. Configuration files can also be downloaded from a local file to an SMD2000-24T with a TFTP PUT command. Refer to your TFTP program’s help for further instructions.

SMD2000-24T Backup

An SMD2000-24T backup file records all management and port configurations.

Table 6. Backup Criteria

Item

Data Needed for Backup

Example

 

 

 

Host Name

DSLAM_IP Address (xxx.xxx.xxx.xxx)

193.166.254.98

 

 

 

Remote

NVR_BACKUP.BIN.[superuser password]

nvr_backup.bin.Password

Filename

 

 

 

 

 

Local

user preference

smd4_backup.bin

Filename

 

 

 

 

 

17

Image 17
Contents SMD2000-24T 24-Port Shdsl Mini Dslam ContentsSoftware and Firmware License Agreement Product Documentation Online Site Selection Criteria Unpacking and Inspecting the EquipmentProcedure Installing Uplink Interface Modules OptionalUIM Side View Standoffs Tabletop Installation Rack Installation Powering Up the SMD2000-24T Negative Batt Lead Connecting the Shdsl RJ21 Cable Loop Bonded Shdsl Connection Connecting to the Remote Shdsl ModemsSingle Line Shdsl Connection Verifying the ConnectionsConnecting the Uplink Lines Shdsl Parameter Defaults Default SettingsT1 Uplink Parameter Defaults Shdsl Defaults ParameterUser Access Defaults System and Management DefaultsSystem and Management Defaults Parameter Username and Password Defaults Username/Passwords AccessBackup Criteria Data Needed for Backup Example SMD2000-24T BackupData Storage MemoryShdsl Port Template Template Criteria Data Needed for Backup ExampleSMD2000-24T Template System Clear Reset ButtonSystem Reset LEDs 1 State Indication Additional Information LED IndicatorsLNK LEDs 2 State Indication Additional InformationShdsl LEDs 3 State Indication Additional InformationShdsl RJ21 Pinouts Shdsl RJ21 Pinouts Connector Pins Port Ring, TipPin Assignments T1 RJ48C Pin Assignments 10/100BaseT RJ45 PinoutsEthernet RJ45 Connection Pin T1 RJ48C Pin Assignments FunctionDB9 to 8-Pin Modular Adapter Pinouts SMD2000-24T Technical Specifications Criteria Technical SpecificationsActa Customer Information EMI NoticesUnited States EMI Notice Canada EMI NoticeCE Marking Class a ITE Japan NoticeImportant Safety Instructions Warranty, Sales, Service, and Training Information SMD2-A2-GN11-00