7. Operation and Maintenance

ISDN DBM Operation

he following sections only apply to units with an ISDN DBM:

Forcing Backup (Disruptive)

Placing a Test Call (Nondisruptive)

TVerifying ISDN Lines

Verifying That Backup Can Take Place

Forcing Backup (Disruptive)

Use this procedure to force backup when network maintenance is planned, when equipment problems are reported, or when testing the backup path – whenever data needs to be forced from the primary destination interface to the alternate destination, typically from the T1 network to the ISDN.

Procedure

1.Make sure the ISDN Link Profiles are set up correctly, Auto Backup is enabled, and the ISDN interface is enabled (see Setting Up Dial Backup in Chapter 4, Configuration Options).

2.Have someone at the far end disconnect the network cable to initiate backup.

3.Verify that backup is taking place.

See Verifying That Backup Can Take Place on page 7-74.

NOTE:

When an alarm requiring backup is received, backup can be manually controlled by enabling or disabling the Auto Backup option (see Step 2).

4. Have the far-end network cable reconnected to return to standard operation.

7-72

September 2002

9128-A2-GB20-80

Image 254
Contents FrameSaver SLV Document Feedback Warranty, Sales, Service, and Training InformationCopyright 2002 Paradyne Corporation All rights reserved TrademarksContents September ConfigurationTProceduresConfiguration Options Configuring the FrameSaver SLV Router IiiSecurity and Logins Operation and MaintenanceTroubleshooting Lamp Test Menu HierarchyT Setting Up NetScout Manager Plus for FrameSaver DevicesSetting Up Network Health for FrameSaver Devices ViiViii Snmp MIBs and Traps, and Rmon Alarm DefaultsRouter CLI TCommands, Codes, and Designations Router Command Line Summaries and Shortcuts Connectors, Cables, and Pin AssignmentsTechnical Specifications Equipment List IndexSection Description Purpose and Intended AudienceDocument Organization Xii Section DescriptionDocument Number Document Title Product-Related DocumentsXiii Conventions Used XivAbout the FrameSaver SLV System OverviewCSU/DSU-Specific Features Router-Specific FeaturesAbout the FrameSaver SLV FrameSaver Diagnostic and SLM Feature Sets FrameSaver Diagnostic Feature Set Through 120 Connections PVCs Dedicated Management FrameSaver SLV Feature RouterMaximum Number of PVCs and Management PVCs Supported About the FrameSaver SLV About the FrameSaver SLV Additional FrameSaverTSLV 9126-II and 9128-II Features Additional FrameSaver SLV 9128-II FeaturesFrameSaver SLM Feature Set OpenLane SLM System NetScout Manager Plus and NetScout Probes User Interface and Basic Operation Procedure Logging OnIf your login was Hen Main Menu SelectScreen Work Areas Screen Format DescriptionPress Navigating the ScreensKeyboard Keys Function Keys For the screen Select Function Press Enter toSwitching Between Screen Areas Selecting from a MenuEntering Information Screen ContentsSelecting a Field Navigating the Router’s CLI CLI Keyboard KeysConfiguration Procedures Basic ConfigurationConfiguration Menu IsdnConfiguration Option Areas Configuration Option Area DescriptionAccessing and Displaying Configuration Options Main Menu → ConfigurationChanging Configuration Options Configuration → PVC ConnectionsSaving Configuration Options Configuration Options Configuration Options Easy Install Screen Example Using the Easy Install FeatureMain Menu → Easy Install Using RIP with FrameSaver SLV CSU/DSUs Configuration → Data Ports→ Dlci RecordsIf the selection is Enter Entering System Information and Setting the System ClockMain Menu → Control→ System Information Main Menu → Control→ Modem Call Directories Setting Up the ModemSetting Up Call Directories for Trap Dial-Out Valid characters include ForSetting Up to Use the Modem PassThru Feature Auto-Configuration Screen Example Setting Up Auto-ConfigurationMain Menu → Auto-Configuration Discovery Mode Configuration Description Selecting a Frame Relay Discovery ModeMain Menu → Auto-Configuration→Frame Relay Discovery Mode Only applies to models withDiscovery Mode Configuration Description Automatically Removing a Circuit Main Menu → Configuration → Isdn → Physical Setting Up Dial BackupSetting Up the DBM Physical Interface Setting Up Automatic Backup Configuration If you select ThenFollowing prompt When Appears If you select From PVCs Remove AlternateDestinations Delete unusedModifying Isdn Link Profiles Main Menu → Configuration → Isdn → Link ProfilesFor Originating a Backup Call For Answering a Backup Call Restricting Automatic Backup and Configuring Backup Timers Main Menu → Configuration → Auto-Backup CriteriaConfiguring the DBM Interface to Send Snmp Traps Assigning DLCIs to a Backup GroupChanging Operating Mode PVC Backup Over the Network InterfaceSetting Up Back-to-Back Operation Main Menu → Control→ Change Operating ModeConfiguration Option Tables Main Menu → Configuration → System → Frame Relay and LMI Configuring the Overall SystemConfiguring Frame Relay and LMI for the System CSU/DSUs System Frame Relay and LMI Options 1System Frame Relay and LMI Options 2 System Frame Relay and LMI Options 3 LMI Status Enquiry N1 Possible Settings 1, 2, 3, 4LMI Heartbeat T1 Possible Settings 5, 10, 15, 20, 25 System Frame Relay and LMI Options 4 Configuring Class of Service Definitions Field Setting After RfcCodePoints SelectedMeasure Latency & Availability Class of Service DefinitionsClass of Svc Name Code Points AssignedCode Pnt Code Point DefinitionsCode Point Definitions NameSLV Type Available Settings Standard, COS 1-COS Configuring Service Level Verification OptionsService Level Verification Options 1 SLV Sample Interval secsSLV Timeout Error Event Threshold Service Level Verification Options 2Dlci Down on SLV Timeout SLV Timeout Clearing Event ThresholdSLV Packet Size bytes Service Level Verification Options 3SLV Latency Clearing Event Threshold Test Timeout Configuring General System OptionsMain Menu → Configuration → System→ General General System Options 1General System Options 2 System Alarm Relay General System Options 3Main Menu → Configuration → Network→ Physical Configuring Physical InterfacesConfiguring the Network Interface Network Physical Interface Options 1Bit Stuffing Line Build Out LBO Possible Settings 0.0, -7.5, -15Network Physical Interface Options 2 Transmit TimingNetwork Initiated PLB Network Initiated Dclb Possible Settings Disable, V.54&ANSINetwork Physical Interface Options 3 Ansi Performance Report MessagesNetwork Physical Interface Options 4 Circuit IdentifierPort Use Possible Settings Frame Relay, Synchronous Data Configuring a User Data Port CSU/DSUsMain Menu → Configuration → Data Ports→ Physical Data Port Physical Interface Options 1Port Base Rate Kbps Data Port Physical Interface Options 2Max Port Rate Kbps Transmit Clock SourceMonitor DTR Data Port Physical Interface Options 3Monitor RTS Control Invert Transmit and Receive Data Data Port Physical Interface Options 4Port DTE Initiated Loopbacks Action on Network Yellow Alarm Data Port Physical Interface Options 5DSX-1 Physical Interface Options 1 Configuring the DSX-1 InterfaceMain Menu → Configuration → DSX-1 Interface StatusDSX-1 Physical Interface Options 2 Send All Ones on DSX-1 FailureIsdn BRI DBM Physical Interface Options Configuring the Isdn DBM InterfaceService Profile ID Spid 1 or Local Phone Number 1 orLocal Phone Number Switch Type Possible Settings NI-2, ATT4ESS, ATT5ESS10. Isdn PRI DBM Physical Interface Options 1 10. Isdn PRI DBM Physical Interface Options 2 10. Isdn PRI DBM Physical Interface Options 3 11. Isdn Link Profile Options 1 Setting Up Isdn Link ProfilesMain Menu → Configuration → Isdn → Isdn Link Profiles Link NameInbound Calling ID 1 or 11. Isdn Link Profile Options 2Outbound Phone Number Maximum Link Rate KbpsCaller Identification Method Assigning Time Slots/Cross Connections11. Isdn Link Profile Options 3 Alternate Outbound Phone NumberValue Meaning Assigning Frame Relay Time Slots to the Network InterfaceFrame Relay Network Time Slot Assignment Screen Example Ntt Assigning DSX-1 Time Slots to the Network InterfaceTime Slot Assignment Rule DSX-1 to Network Time Slot Assignment Screen Example Ime Slot Assignment RulesDSX-1 Signaling Assignments and Trunk Conditioning RBS Idle PLAR3idle Synchronous Data Port Assignment Screen Example Sync Data Port AssignmentClearing Assignments Physical Interface OptionsLMI Configuring Frame Relay for an Interface13. Interface Frame Relay Options 1 LMI Parameters 13. Interface Frame Relay Options 2Traffic Policing Frame Relay DS0s Base Rate13. Interface Frame Relay Options 3 Dlci Number Manually Configuring Dlci Records14. Dlci Record Options 1 Committed Burst Size Bc Bits 14. Dlci Record Options 2CIR bps Dlci Priority 14. Dlci Record Options 3Excess Burst Size Bits Outbound Management PriorityBackup Group Possible Settings A, B, C, . . . Z, None 14. Dlci Record Options 415. PVC Connection Options 1 Configuring PVC ConnectionsMain Menu → Configuration → PVC Connections Source DlciPrimary Destination Link 15. PVC Connection Options 2Source Edlci Primary Destination DlciAlternate Destination Link 15. PVC Connection Options 3Primary Destination Edlci Alternate Destination Dlci15. PVC Connection Options 4 Alternate Destination Edlci16. IP Path List Configuring the IP Path ListMain Menu → Configuration → IP Path List Static Enter IP Address press ESC to abort ... FWD NoSetting Up Management and Communication Options Configuring Node IP Information 17. Node IP Options 1TS Access Management Link 17. Node IP Options 217. Node IP Options 3 TS Management Snmp ValidationConfiguring Management PVCs 18. Management PVC Options 1Set DE 18. Management PVC Options 2Payload Managed 18. Management PVC Options 3 Primary Dlci18. Management PVC Options 4 Primary EdlciAlternate Edlci 18. Management PVC Options 5Alternate Dlci 18. Management PVC Options 6 Encapsulation19. General Snmp Management Options 1 Configuring General Snmp ManagementName 1 Access Snmp Management19. General Snmp Management Options 2 Configuring Telnet and/or FTP Session SupportName 2 Access Telnet Session Telnet Login Required20. Telnet and FTP Session Options 1 20. Telnet and FTP Session Options 2 NMS IP Validation Configuring Snmp NMS Security21. Snmp NMS Security Options 1 Number of Managers22. Snmp Traps and Trap Dial-Out Options 1 Configuring Snmp Traps and Trap Dial-Out21. Snmp NMS Security Options 2 22. Snmp Traps and Trap Dial-Out Options 2 Enterprise Specific Traps Link Traps Possible Settings Disable, Up, Down, Both22. Snmp Traps and Trap Dial-Out Options 3 Dlci Traps on Interfaces Filter Selection Field Possible Settings Network, Ports, DBM, All, None22. Snmp Traps and Trap Dial-Out Options 4 Rmon TrapsTrap Dial-Out Dial-Out Delay TIme Min22. Snmp Traps and Trap Dial-Out Options 5 Trap DisconnectLatency Traps 22. Snmp Traps and Trap Dial-Out Options 6Alternate Dial-Out Directory IP SLV Availability TrapsConfiguring Ethernet Management 23. Ethernet Management Options 123. Ethernet Management Options 2 Proxy ARPCharacter Length Configuring the Communication Port24. Communication Port Options 1 Parity Login Required24. Communication Port Options 2 Stop Bits24. Communication Port Options 3 24. Communication Port Options 4 RIP24. Communication Port Options 5 Configuring the Modem Port100 25. Modem Port Options 1101 25. Modem Port Options 2102 25. Modem Port Options 3103 25. Modem Port Options 426. Auto Backup Criteria Options 1 Configuring the Criteria for Automatic BackupMain Menu → Configuration → Auto Backup Criteria 104Backup Allowed Day From nnnn 26. Auto Backup Criteria Options 2When Auto Backup Allowed Backup Allowed Day To nnnn106 Configuring the FrameSaver SLV Router Ethernet FrameSaver SLV Router OverviewNetwork Interface Proxy ARP Address Resolution ProtocolIP Routing Interface Configuration Applications Supported by NAT Network Address TranslationIP Options Processing NAT Configuration Example NAT Mapping Public IP Addresses Private IP AddressesSave exit Napt Mapping Public IP Address Private IP Addresses Napt Configuration ExampleNetwork Address Port Translation Int ethernet 0 ip nat inside int serial 0.x ip nat outside Access-list 1 permit 10.1.3.0Ip nat inside source list 1 interface se 0.x overload NAT and Napt Configuration Example Ip nat inside source static 10.1.1.1Dynamic Host Configuration Protocol Server Dhcp Server with NAT Configuration Example Public IP Addresses for NAT Private IP AddressesDhcp Server at Remote Site Configuration Example Dhcp Relay AgentBridge Filtering Router SecurityIP Router Filtering Land Bug Prevention Provisioning the Router InterfaceIP Filtering Smurf Attack PreventionConfiguring the Router Using Terminal Emulation Security and Logins Limiting Access Controlling Asynchronous Terminal AccessSet the configuration option Limiting Dial-In Access via the Modem Port Isdn Call Security Controlling Isdn AccessDisabling Isdn Access Controlling Telnet or FTP Access Limiting Telnet AccessLimiting FTP Access Has a Level-1 login and Level-2 telnet access has Controlling Snmp Access Disabling Snmp AccessAssigning Snmp Community Names and Access Levels General Snmp Management → Snmp Management Enable Limiting Snmp Access Through IP AddressesMain Menu → Configuration → Management and Communication →Field Enter Creating a LoginMain Menu → Control→ Administer Logins Modifying a Login Deleting a LoginLargo Controlling Router CLI AccessAccess Levels Command Modes Enable password password Changing Access LevelsEnable EndSecurity and Logins September Operation and Maintenance Operation and Maintenance View this field To find Displaying System InformationMain Menu → Status → Identity Viewing LEDs and Control Leads Isdn DBMFrameSaverTM SLV FrameSaver SLV 9126 LEDs and Control LeadsMain Menu → Status → Display LEDs and Control Leads Display LEDs & Control Leads Screen for a FrameSaver SLVFrameSaver SLV 9128-II LEDs and Control Leads Main Menu → Status → Display LEDs and Control LeadsLabel Indiction Color What It Means LED DescriptionsGeneral Status LEDs 1 ALMModel General Status LEDs 2Contd 9128-IIUser Data Port LED CSU/DSUs Only Network, DSX, or PRI Interface LEDsLabel Indication Color What It Means Ethernet Port LED Routers OnlyNetwork Interface Control Lead DescriptionsAdditional Control Leads Label Indication What It Means User Data PortSeen at an FTP Device MessagesDevice Messages 1 What It Indicates What To Do TerminalDevice Messages 2 What It Indicates What To Do See Changing Software onDevice Messages 3 What It Indicates What To Do PVCDevice Messages 4 What It Indicates What To Do FrameSaver SLV Reset COM Port usageDevice Messages 5 What It Indicates What To Do II onlyDevice Messages 6 What It Indicates What To Do Status Information Status Menu ExampleMain Menu → Status → System and Test Status Last System Reset Date and TimeSystem and Test Status Messages Self-Test Results MessagesHealth and Status Messages 1 What It Indicates Change Operating ModeHealth and Status Messages Isdn PRI DBM onlyFrameSaver SLV 9126-II or Health and Status Messages 2 What It IndicatesFrame relay link 1,2 Health and Status Messages 3 What It Indicates Health and Status Messages 4 What It Indicates Framerelaylink 1,2PathIP Address Down Series Access Carrier onlyHealth and Status Messages 5 What It Indicates Nnnn, framerelaylink 1,2Health and Status Messages 6 What It Indicates Relay Network Assignments and an LMI failure is Configuration→ Time Slot Assignment → FrameHealth and Status Messages 7 What It Indicates Dclb Active, framerelaylink 1 or Test Status MessagesTest Status Messages 1 What It Indicates Framerelaylink 1 ,3Test Status Messages 2 What It Indicates LMI-Reported DLCIs Status Screen Example Network LMI-Reported DLCIs StatusMain Menu → Status→ LMI Reported DLCIs Tframe relay network, or IP Path Connection Status Screen Example IP Path Connection StatusMain Menu → Status→ IP Path Connection Status 11. IP Path Connection Status Field What It Indicates PVC Connection Status Screen Example PVC Connection StatusMain Menu → Status→ PVC Connection Status Edlci 12. PVC Connection Status 1 Field What It IndicatesMgmtPVCName 12. PVC Connection Status 2 Field Status What It IndicatesMain Menu → Status→ Timeslot Assignment Status → Network Time Slot Assignment StatusDisplaying Network Time Slot Assignments Network Timeslot Assignment Status Screen ExampleMain Menu → Status→ Timeslot Assignment Status→ DSX-1 Cross Connect Status Field bottom IndicatesDisplaying DSX-1 Time Slot Assignments DSX-1 Timeslot Assignment Status Screen ExampleDBM Interface Status Screen Example DBM Interface StatusMain Menu → Status→ DBM Interface Status 13. DBM Interface Status 1 Field What It Indicates Invalid Call ID is displayedAwarded and Being Link Name Disabled13. DBM Interface Status 2 Field What It Indicates Delivered In Est Chnl-7Being Delivered In Est 13. DBM Interface Status 3 Field What It IndicatesValue is Call Awarded Chnl-7Most Recent and Previous Cause Value Messages Make sure the network is Operation and Maintenance Normal class applies for this Correct number Operation and Maintenance IP Routing Table Screen Example IP Routing TableMain Menu → Status→ IP Routing Table 15. IP Routing Table Values 1 Column What It Indicates15. IP Routing Table Values 2 Column What It Indicates TTLPerformance Statistics Menu Performance StatisticsMain Menu → Status→ Performance Statistics Clearing Performance Statistics Service Level Verification Performance Statistics 17, SLV Performance Statistics for IP Enabled DlciVerification Options, in , Configuration Options, must Verification Options, in , Configuration Options, over Service Definitions in , Configuration Options COS IDSize is changed, a new average is not available until a new 18. Dlci Performance Statistics 1 What It Indicates Dlci Performance StatisticsMain Menu → Status → Performance Statistics→ Dlci 18. Dlci Performance Statistics 2 What It Indicates Additional Performance Statistics for IP Enabled Dlci For FrameSaver units with an Isdn DBM Frame Relay Performance StatisticsMain Menu → Status → Performance Statistics→ Frame Relay 20. Frame Relay Performance Statistics 1 What It IndicatesFrame Relay Errors 20. Frame Relay Performance Statistics 2 What It Indicates20. Frame Relay Performance Statistics 3 What It Indicates Frame Relay LMIFrame Relay Hdlc Errors 20. Frame Relay Performance Statistics 4 What It IndicatesTo select intervals You must enter an interval or time on ESF Line Performance StatisticsMain Menu → Status → Performance Statistics→ ESF Line ESF Line Performance Statistics Screen Example LofcUAS LofcDBM Call Performance Statistics 22. DBM Call Performance Statistics What It Indicates23. Ethernet Performance Statistics What It Indicates Ethernet Performance StatisticsMain Menu → Status → Performance Statistics → Ethernet Trap Event Log Screen Example Trap Event LogMain Menu → Status → Trap Event Log Main Menu → Control→ Enable Modem PassThru to COM Activating the Modem PassThru FeatureCanceling Modem PassThru Operation Main Menu → Control→ Disable Modem PassThru to COMMain Menu → Control→ Disconnect Modem Manually Disconnecting the ModemVerifying Modem Operation Forcing Backup Disruptive Isdn DBM OperationIf the Result is Then Placing a Test Call NondisruptiveMain Menu→ Test→ Isdn Call/PVC Tests System Operational should appear Verifying That Backup Can Take PlaceVerifying Isdn Lines FTP File Transfers Command Definition Upgrading System Software If the message displayed is ThenUpgrading Isdn BRI DBM Software Main Menu → Status→ IdentityMain Menu → Control→ Select Software Release Determining Whether a Download Is CompletedChanging Software Transferring Collected Data If retrieving HenTurning Off the System Alarm Relay Main Menu → Control→ System Alarm Relay Cut-OffOperation and Maintenance September Troubleshooting Operation and Maintenance Problem IndicatorsIndicators See Main Menu → Status → Display LEDs and Control LEDsResetting the Unit By Cycling the Power Resetting the Unit and Restoring CommunicationResetting the Unit from the Control Menu Restoring Communication with an Improperly Configured Unit If selecting He following occursTroubleshooting Management Link Feature LMI Packet Capture Utility FeatureLMI Packet Capture Utility→ Display LMI Trace Log LMI Trace Log ExampleMenu → Control → Reset Device AlarmsAlarm Conditions 1 What It Indicates What To Do Name Alarm Conditions 2 What It Indicates What To DoMain Menu → Configuration → Isdn → Link Profiles IPAddressLMI Down, frame relay Alarm Conditions 3 What It Indicates What To DoMenu→ Configuration→ LinkAlarm Conditions 4 What It Indicates What To Do DTEAlarm Conditions 5 What It Indicates What To Do PathIP AddressAlarm Conditions 6 What It Indicates What To Do Nnnn , frame relayAlarm Conditions 7 What It Indicates What To Do Device Problems 1 Symptom Possible Cause Solutions Troubleshooting TablesDevice Problems Viewing the Trap Event LogDevice Problems 2 Symptom Possible Cause Solutions Improperly Configured Unit onFrame Relay PVC Problems Frame Relay PVC Problems Symptom Possible Cause SolutionsMain Menu → Status → DBM Interface Status Isdn DBM ProblemsIsdn DBM Problems Symptom Possible Cause Solutions Tests Available Test Menu ExampleTest Timeout Feature DBM TestsWhen the status of a test is Only command available is Starting and Stopping a TestAborting All Tests PVC Tests PVC Tests Screen ExampleMain Menu → Test→ Data Port PVC Tests PVC LoopbackMain Menu → Test→ Network PVC Test Main Menu → Test→ Isdn Call/PVC TestsNetwork PVC Tests/Data Port PVC Tests Send PatternMonitor Pattern Isdn Call/PVC TestsConnectivity Test CallPhysical Tests Physical Tests Screen ExampleLLB Line LoopbackMain Menu → Test→ Network Physical Tests Payload Loopback PLBRepeater Loopback RLB AISDSX DTE LoopbackMain Menu → Test→ Data Port Physical Tests Dtlb DTESend Line Loopback Data Channel Loopbacks on a Frame Relay Link Send Remote Line Loopback Main Menu → Test→ Network Physical Tests/PRI Physical TestsSend and Monitor Pattern Tests QrssIP Ping Test Ping Screen ExamplePing Options 1 Target IP AddressSource IP Address Inter-Ping DelayPing Options 2 Packet SizePing Responses Field Possible Values Description Response TimeoutPing Options 3 IP Ping Test Procedure Main Menu → Test→ IP PingLamp Test Main Menu → Test→ Lamp TestHis chapter includes Setting Up the OpenLane SLM System OpenLane Support of FrameSaver DevicesSetting Up FrameSaver Support Ordering SLM Feature Set Activations To Find Your License Key NumberActivation Certificate Administering and Managing SLM Activations Entering an Activation Certificate Checking Activation Certificate StatusScheduling Activations Checking the Status of Scheduled Activations Canceling Scheduled ActivationsAccessing and Printing the Certificate Summary Report 9128-A2-GB20-80 Setting Up NetScout Manager Plus for FrameSaver Devices 10-110-2 AlarmsPreparation PropertiesConfiguring NetScout Manager Plus 10-310-4 Verifying Domains and Groups 10-5Correcting Domains and Groups 10-6Property Description Setting 10-7Adding SLV Alarms Using a Template 10-8Editing Alarms 10-910-10 Adding SLV Alarms Manually 10-11Paradyne 10-12Field Select or Enter Creating History Files 10-1310-14 Change 1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI toDvuhist -f Dallas51 301 3 config 30 60 Dallas301.udh Installing the User-Defined History FilesDvuhist -f Dallas51 3 config 30 60 Dallas51k.udh 10-15Monitoring a DLCI’s History Data 10-1610-17 Monitoring the Agent Using NetScout Manager Plus 10-1810-19 Traffic Statistics Protocol Statistics Statistical Windows Supported10-20 Setting Up Network Health for FrameSaver Devices 11-1Installation and Setup of Network Health 11-2Discovering FrameSaver Elements 11-3Configuring the Discovered Elements 11-4Grouping Elements for Reports 11-5About At-a-Glance Reports About Service Level ReportsGenerating Reports for a Group 11-6Printed Reports Reports Applicable to SLV DevicesAbout Trend Reports 11-711-8 11-9 FrameSaver SLV Plus At-a-Glance Report11-10 Menu Hierarchy MenusStatus Easy Install Menu Hierarchy September Snmp MIBs and Traps, and Rmon Alarm Defaults MIB Support Downloading MIBs and Snmp TrapsFrameSaver Unit’s sysDescr system System Group mib-2Interfaces Group mib-2 FrameSaver Unit’s sysObjectID systemFrame Relay Logical Layer NAM Profile Link NameFR DTE T1 FR NAM FR Service T1 FR NAMNetScout Indexes to the Interface Table ifTable Number Dlci number ALL Rmon Logical LayerIfName of the interface Number Dlci number DTEStandards Compliance for Snmp Traps ExamplesTable B-3. warmStart Trap What It Indicates Possible Cause Trap authenticationFailureTrap warmStart Variable-BindingTraps linkUp and linkDown MIB Physical SublayerPRI StringsBRI Logical Link SublayerTraps enterprise-Specific Xxx.xxx.xxx.xxx , COS nnNnnn ’ ‘Path xxx.xxx.xxx.xxx UpThat the secondary clock source Traps RMON-Specific Trap dialControl Standard Dial Control MIBEventIndex EventDescription EventType EventCommunity Rmon Alarm and Event DefaultsEvent Defaults Dial Control Extension MIBPhysical Interface Alarm Defaults Rising Event OperationFrame Relay Link Alarm Defaults Snmp MIBs and Traps, and Rmon Alarm Defaults Dlci Alarm Defaults Paradyne Area MIB FR DTE MIB RFCDlci Alarm Defaults NetScout Area OID Rx Dlci Link Object ID Cross-References Numeric Order 6.1.2.1.16.12.2.1 6.1.2.1.2.2.16.1.2.1.2.10.32.2.1 MIB Rmon II RFCDlci CIR 6.1.4.1.1795.2.24.26.1.4.1.1795.2.24.2.6.9.4 CIRDlci EIR 6.1.4.1.1795.2.24.2.6.9.4.7.1 6.1.4.1.1795.2.24.2.6.9.4.4.26.1.4.1.1795.2.24.2.6.9.4.5.2.1 6.1.4.1.1795.2.24.2.6.9.4.10.3.1 6.1.2.1.10.18.9.1 6.1.2.1.10.32.2.16.1.4.1.1795.2.24.2.6.9.4 6.1.4.1.1795.2.24.2.6.9.4 X.x CLI CommandsConvention Meaning XxxxxxxxxxxxRouter CLI Commands, Codes, and Designations Table C-1. Pager Command Pager CommandAccess Control Commands Table C-2. Access Control CommandsConfigure terminal factory Configuration CommandsTable C-3. Configuration Commands Example configure terminalCommand Mode config, config-if, config-subif Interface CommandsTable C-4. Interface Commands 1 Example interface serial 132.53.4.2Example ip address 132.53.4.2 Table C-4. Interface Commands 2Encapsulation encapsulation-type encapsulation-protocol Example encapsulation frame-relay ietfNo frame-relay interface-dlci dlci-num Table C-4. Interface Commands 3No ip unnumbered null Example ip unnumberedNo ip routing IP Routing CommandsTable C-5. IP Routing Commands No ip multicast-routingExample bridge crb 1 route ip Bridge CommandsTable C-6. Bridge Commands 1 No bridge-group bridge-group Table C-6. Bridge Commands 2Command Mode config-if, config-subif Example no bridge-groupArp timeout time No arp timeout time ARP CommandsTable C-7. ARP Commands Example arp timeoutExample ip nat translation timeout NAT CommandsTable C-8. NAT Commands 1 No ip nat inside outsideNetmask netmask prefix-length / prefix-length Table C-8. NAT Commands 2Ip nat pool pool-name start-ip-addr end-ip-addr No ip nat pool pool-namestart-ip-addr end-ip-addrFrom previous Table C-8. NAT Commands 3Clear ip nat translation No service dhcp Dhcp Server CommandsTable C-9. Dhcp Server Commands 1 No ip dhcp pool pool-nameDomain-name domain-name No domain-name domain-name Table C-9. Dhcp Server Commands 2Default-router ip-address No default-router ip-address Dns-server ip-address No dns-server ip-addressTable C-9. Dhcp Server Commands 3 Network network-numNo ip dhcp-server ip-address Dhcp Relay Agent CommandsTable C-10. Dhcp Relay Agent Commands Example ip dhcp relay max-clientsAccess-list access-list-num permit deny Filter access-list CommandsTable C-11. Filter Commands 1 No access-list access-list-numpermit denyTable C-11. Filter Commands 2 For Extended IP Access ListsExample access-list 200 permit 0x200 range Table C-11. Filter Commands 3For Protocol Type Access Lists Table C-11. Filter Commands 4 No ip access-group access-list-1-199numin outDiagnostic Commands Table C-12. Diagnostic Commands 1Table C-12. Diagnostic Commands 2 Traceroute protocol dest-ipsource source-ip length bytesShow configuration Show CommandsTable C-13. Show Commands 1 Show arpShow frame-relay map Table C-13. Show Commands 2Show configuration saved unsaved Show interface intf-type intf-num .sub-intf-numShow ip nat translations Table C-13. Show Commands 3Show ip dhcp binding ip-address Show ip route ip-addressShow spanning-tree Table C-13. Show Commands 4Show ip traffic Ethernet Type Codes Table C-14. Ethernet Type Codes Hex 1 DescriptionTable C-14. Ethernet Type Codes Hex 2 Description All 3 n = Destination unreachable Protocol and Port DesignationsIcmp Designations All 5 n = All redirects TCP Port Designations UDP Port Designations Router Command Line Summaries Shortcuts CLI SummariesIntf-type intf-num .sub-intf-num Show Command SummaryTable D-1. Show Commands Function Access Control and System Level Command Summary Table D-2. Access Control and System Level Commands FunctionClear counters intf-type intf-num .sub-intf-num CLI Command SummaryTable D-3. CLI Commands 1 Dns-serverip-addressTable D-3. CLI Commands 2 Encapsulation encapsulation-type encapsulation-protocolCLI Command Default Settings Connectors, Cables, and Pin Assignments Rear PanelsConnectors, Cables, and Pin Assignments Model Pin # Signal Direction COM Port ConnectorSignal Direction Pin # COM Port for 9126 and 9128-II 25-PositionCOM Port Non-Keyed Position COM Port-to-PC Cable Feature No -F2-550COM Port for 9128-II Carrier Mount Modular Plug DB9 SocketPosition Modular Plug DB25 Plug COM Port-to-Terminal/Printer Cable Feature No -F2-540COM Port Non-Keyed COM Port-to-Router Cables COM Port AUX Port Signal DB25 Pin # Direction RJ45 Pin #COM Port AUX Port Signal DB25 Pin # Direction Cisco 2500 Series Router RJ45 Jack3COM Router DB9 Socket COM Port Console Port Signal DB25 Pin # Direction DB9 Pin #COM Port AUX Port Signal RJ45 Pin # Direction COM Port AUX Port Signal RJ45 Pin # Direction DB25 Pin # Plug-to-Modular Jack Converter Com Port Position DB25 Plug Gender Adapter/ChangerLAN Adapter Converter and Cable DTR RTSDTE Port Connector Direction Pin SocketMM NN Standard V.35 Straight-through CableStandard V.35 Crossover Cable PinFunction Circuit Direction Pin Number DSX-1 ConnectorDSX-1 Adapter Feature No -F1-560 Position DB15 Modular Plug Socket UnkeyedDSX-1 Port for 1-Slot 9128-II 15-Position Function Circuit Line # Pin # T1 Network Cable Feature No -F1-500T1 Mass Termination Cable Feature No -F1-500 Plug Unkeyed Ethernet Port ConnectorCanadian T1 Line Interface Cable Feature No -F1-510 Isdn Modular Cable Modem ConnectorIsdn DBM Connector Connectors, Cables, and Pin Assignments September Approvals Table F-1. NAM Technical Specifications 1 CriteriaPhysical Dimensions Physical EnvironmentTable F-1. NAM Technical Specifications 2 Criteria B8ZS Table F-1. NAM Technical Specifications 3 CriteriaIsdn PRI DBM Interface Ethernet PortPower Consumption Dissipation Ethernet Port FrameSaver Isdn BRI DBM InterfaceBRI, NI-1 Heat Dissipation Max AC Power RequirementsTypical Power Consumption Switched Network Interface Switch CompatibilityService Supported Standards ComplianceLine Build-Out LBO Framing FormatCoding Format Description Number Model/FeatureEquipment FrameSaver SLV UnitsEquipment List Isdn PRI DBM Power Supplies FrameSaver SLM Feature Set UpgradeOptional Features NMS ProductsSeries Access Carrier 9128-II NAM only Description Part Number Feature Number CablesIndex IN-1CLI IN-2Becn IN-3 DhcpIN-4 DBMEIR IN-5EER IN-6 IP SLV IN-7LAN LOS IN-8LOF IN-9 NMSIN-10 OIDIN-11 PortIN-12 IN-13 IN-14 IN-15 IN-16