Paradyne CSU, DSU, 9126 Assigning Frame Relay Time Slots to the Network Interface, Value Meaning

Page 96

4. Configuration Options

Assigning Frame Relay Time Slots to the Network Interface

Before assigning network time slots for use by frame relay traffic, configure the

Network physical and Frame Relay options (if needed), then allow Time Slot

Discovery to autodetect and assign the appropriate time slots to frame relay.

If there are multiple Frame Relay data links on the network interface, or if Time Slot Discovery is not currently active, you can manually assign time slots on the network interface for frame relay traffic using the Frame Relay Network Assignments screen. This screen is read-only when Time Slot Discovery is set to Enable for the network interface.

Frame Relay Network Time Slot Assignment Screen Example

main/config/tslot_assign/frame_relay

 

 

 

9128-II

Device Name: Node A

 

 

 

 

5/26/2000 23:32

 

 

FRAME RELAY NETWORK 1 ASSIGNMENT

 

 

 

 

 

Time Slot Discovery: Disable

 

 

N01

N02

N03

N04

N05

N06

N07

N08

Available Available Available Available Available Available Available Available

N09

N10

N11

N12

N13

N14

N15

N16

Available Available FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1

N17

N18

N19

N20

N21

N22

N23

N24

FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1

--------------------------------------------------------------------------------

Ctrl-a to access these

functions, ESC for previous menu

MainMenu Exit

Save PgDn

PgUp

ClearAll

DSXAssign

 

Value

Meaning

 

 

Time Slot

Specifies whether the time slots used for frame relay traffic should be

Discovery

discovered from the network interface upon detection of an LMI

 

failure. This option allows additional time slots to be added without

 

manually reconfiguring the device.

 

 

N tt

This field represents time slot tt of the selected network interface.

 

 

Assigned

The time slot is already assigned to something other than frame

 

relay, so it is unavailable. Assigned time slots cannot be modified

 

from this screen.

 

 

Available

The time slot is currently unassigned.

 

 

FrameRly1

The time slot is assigned to frame relay service, link 1.

 

 

For easy movement between screens, select the DSXAssign function key to go directly to the DSX-1 to Network Assignments screen.

4-52

September 2002

9128-A2-GB20-80

Image 96
Contents FrameSaver SLV Warranty, Sales, Service, and Training Information Copyright 2002 Paradyne Corporation All rights reservedDocument Feedback TrademarksContents ConfigurationTProcedures Configuration OptionsSeptember Configuring the FrameSaver SLV Router IiiSecurity and Logins Operation and MaintenanceTroubleshooting Lamp Test Setting Up NetScout Manager Plus for FrameSaver Devices Setting Up Network Health for FrameSaver DevicesMenu HierarchyT ViiSnmp MIBs and Traps, and Rmon Alarm Defaults Router CLI TCommands, Codes, and DesignationsViii Router Command Line Summaries and Shortcuts Connectors, Cables, and Pin AssignmentsTechnical Specifications Equipment List IndexPurpose and Intended Audience Document OrganizationSection Description Xii Section DescriptionProduct-Related Documents XiiiDocument Number Document Title Conventions Used XivAbout the FrameSaver SLV System OverviewCSU/DSU-Specific Features Router-Specific FeaturesAbout the FrameSaver SLV FrameSaver Diagnostic and SLM Feature Sets FrameSaver Diagnostic Feature Set FrameSaver SLV Feature Router Maximum Number of PVCs and Management PVCs SupportedThrough 120 Connections PVCs Dedicated Management About the FrameSaver SLV About the FrameSaver SLV Additional FrameSaverTSLV 9126-II and 9128-II Features Additional FrameSaver SLV 9128-II FeaturesFrameSaver SLM Feature Set OpenLane SLM System NetScout Manager Plus and NetScout Probes User Interface and Basic Operation Procedure Logging OnIf your login was Hen Main Menu SelectScreen Work Areas Screen Format DescriptionNavigating the Screens Keyboard KeysPress Function Keys For the screen Select Function Press Enter toSwitching Between Screen Areas Selecting from a MenuScreen Contents Selecting a FieldEntering Information Navigating the Router’s CLI CLI Keyboard KeysConfiguration Procedures Basic ConfigurationConfiguration Menu IsdnConfiguration Option Areas Configuration Option Area DescriptionAccessing and Displaying Configuration Options Main Menu → ConfigurationChanging Configuration Options Configuration → PVC ConnectionsSaving Configuration Options Configuration Options Configuration Options Using the Easy Install Feature Main Menu → Easy InstallEasy Install Screen Example Using RIP with FrameSaver SLV CSU/DSUs Configuration → Data Ports→ Dlci RecordsEntering System Information and Setting the System Clock Main Menu → Control→ System InformationIf the selection is Enter Setting Up the Modem Setting Up Call Directories for Trap Dial-OutMain Menu → Control→ Modem Call Directories Valid characters include ForSetting Up to Use the Modem PassThru Feature Setting Up Auto-Configuration Main Menu → Auto-ConfigurationAuto-Configuration Screen Example Selecting a Frame Relay Discovery Mode Main Menu → Auto-Configuration→Frame Relay Discovery ModeDiscovery Mode Configuration Description Only applies to models withDiscovery Mode Configuration Description Automatically Removing a Circuit Setting Up Dial Backup Setting Up the DBM Physical InterfaceMain Menu → Configuration → Isdn → Physical Setting Up Automatic Backup Configuration If you select ThenFollowing prompt When Appears If you select Remove Alternate DestinationsFrom PVCs Delete unusedMain Menu → Configuration → Isdn → Link Profiles For Originating a Backup Call For Answering a Backup CallModifying Isdn Link Profiles Restricting Automatic Backup and Configuring Backup Timers Main Menu → Configuration → Auto-Backup CriteriaConfiguring the DBM Interface to Send Snmp Traps Assigning DLCIs to a Backup GroupPVC Backup Over the Network Interface Setting Up Back-to-Back OperationChanging Operating Mode Main Menu → Control→ Change Operating ModeConfiguration Option Tables Configuring the Overall System Configuring Frame Relay and LMI for the System CSU/DSUsMain Menu → Configuration → System → Frame Relay and LMI System Frame Relay and LMI Options 1System Frame Relay and LMI Options 2 LMI Status Enquiry N1 Possible Settings 1, 2, 3, 4 LMI Heartbeat T1 Possible Settings 5, 10, 15, 20, 25System Frame Relay and LMI Options 3 System Frame Relay and LMI Options 4 Configuring Class of Service Definitions Field Setting After RfcCodePoints SelectedClass of Service Definitions Class of Svc NameMeasure Latency & Availability Code Points AssignedCode Point Definitions Code Point DefinitionsCode Pnt NameConfiguring Service Level Verification Options Service Level Verification Options 1SLV Type Available Settings Standard, COS 1-COS SLV Sample Interval secsService Level Verification Options 2 Dlci Down on SLV TimeoutSLV Timeout Error Event Threshold SLV Timeout Clearing Event ThresholdService Level Verification Options 3 SLV Latency Clearing Event ThresholdSLV Packet Size bytes Configuring General System Options Main Menu → Configuration → System→ GeneralTest Timeout General System Options 1General System Options 2 System Alarm Relay General System Options 3Configuring Physical Interfaces Configuring the Network InterfaceMain Menu → Configuration → Network→ Physical Network Physical Interface Options 1Line Build Out LBO Possible Settings 0.0, -7.5, -15 Network Physical Interface Options 2Bit Stuffing Transmit TimingNetwork Initiated Dclb Possible Settings Disable, V.54&ANSI Network Physical Interface Options 3Network Initiated PLB Ansi Performance Report MessagesNetwork Physical Interface Options 4 Circuit IdentifierConfiguring a User Data Port CSU/DSUs Main Menu → Configuration → Data Ports→ PhysicalPort Use Possible Settings Frame Relay, Synchronous Data Data Port Physical Interface Options 1Data Port Physical Interface Options 2 Max Port Rate KbpsPort Base Rate Kbps Transmit Clock SourceData Port Physical Interface Options 3 Monitor RTS ControlMonitor DTR Data Port Physical Interface Options 4 Port DTE Initiated LoopbacksInvert Transmit and Receive Data Action on Network Yellow Alarm Data Port Physical Interface Options 5Configuring the DSX-1 Interface Main Menu → Configuration → DSX-1DSX-1 Physical Interface Options 1 Interface StatusDSX-1 Physical Interface Options 2 Send All Ones on DSX-1 FailureConfiguring the Isdn DBM Interface Service Profile ID Spid 1 orIsdn BRI DBM Physical Interface Options Local Phone Number 1 orSwitch Type Possible Settings NI-2, ATT4ESS, ATT5ESS 10. Isdn PRI DBM Physical Interface Options 1Local Phone Number 10. Isdn PRI DBM Physical Interface Options 2 10. Isdn PRI DBM Physical Interface Options 3 Setting Up Isdn Link Profiles Main Menu → Configuration → Isdn → Isdn Link Profiles11. Isdn Link Profile Options 1 Link Name11. Isdn Link Profile Options 2 Outbound Phone NumberInbound Calling ID 1 or Maximum Link Rate KbpsAssigning Time Slots/Cross Connections 11. Isdn Link Profile Options 3Caller Identification Method Alternate Outbound Phone NumberAssigning Frame Relay Time Slots to the Network Interface Frame Relay Network Time Slot Assignment Screen ExampleValue Meaning Assigning DSX-1 Time Slots to the Network Interface Time Slot Assignment RuleNtt DSX-1 to Network Time Slot Assignment Screen Example Ime Slot Assignment RulesDSX-1 Signaling Assignments and Trunk Conditioning RBS Idle PLAR3idle Synchronous Data Port Assignment Screen Example Sync Data Port AssignmentClearing Assignments Physical Interface OptionsConfiguring Frame Relay for an Interface 13. Interface Frame Relay Options 1LMI 13. Interface Frame Relay Options 2 Traffic PolicingLMI Parameters Frame Relay DS0s Base Rate13. Interface Frame Relay Options 3 Manually Configuring Dlci Records 14. Dlci Record Options 1Dlci Number 14. Dlci Record Options 2 CIR bpsCommitted Burst Size Bc Bits 14. Dlci Record Options 3 Excess Burst Size BitsDlci Priority Outbound Management PriorityBackup Group Possible Settings A, B, C, . . . Z, None 14. Dlci Record Options 4Configuring PVC Connections Main Menu → Configuration → PVC Connections15. PVC Connection Options 1 Source Dlci15. PVC Connection Options 2 Source EdlciPrimary Destination Link Primary Destination Dlci15. PVC Connection Options 3 Primary Destination EdlciAlternate Destination Link Alternate Destination Dlci15. PVC Connection Options 4 Alternate Destination EdlciConfiguring the IP Path List Main Menu → Configuration → IP Path List Static16. IP Path List Enter IP Address press ESC to abort ... FWD NoSetting Up Management and Communication Options Configuring Node IP Information 17. Node IP Options 1TS Access Management Link 17. Node IP Options 217. Node IP Options 3 TS Management Snmp ValidationConfiguring Management PVCs 18. Management PVC Options 118. Management PVC Options 2 Payload ManagedSet DE 18. Management PVC Options 3 Primary Dlci18. Management PVC Options 4 Primary Edlci18. Management PVC Options 5 Alternate DlciAlternate Edlci 18. Management PVC Options 6 EncapsulationConfiguring General Snmp Management Name 1 Access19. General Snmp Management Options 1 Snmp ManagementConfiguring Telnet and/or FTP Session Support Name 2 Access19. General Snmp Management Options 2 Telnet Login Required 20. Telnet and FTP Session Options 1Telnet Session 20. Telnet and FTP Session Options 2 Configuring Snmp NMS Security 21. Snmp NMS Security Options 1NMS IP Validation Number of ManagersConfiguring Snmp Traps and Trap Dial-Out 21. Snmp NMS Security Options 222. Snmp Traps and Trap Dial-Out Options 1 22. Snmp Traps and Trap Dial-Out Options 2 Link Traps Possible Settings Disable, Up, Down, Both 22. Snmp Traps and Trap Dial-Out Options 3Enterprise Specific Traps Possible Settings Network, Ports, DBM, All, None 22. Snmp Traps and Trap Dial-Out Options 4Dlci Traps on Interfaces Filter Selection Field Rmon TrapsDial-Out Delay TIme Min 22. Snmp Traps and Trap Dial-Out Options 5Trap Dial-Out Trap Disconnect22. Snmp Traps and Trap Dial-Out Options 6 Alternate Dial-Out DirectoryLatency Traps IP SLV Availability TrapsConfiguring Ethernet Management 23. Ethernet Management Options 123. Ethernet Management Options 2 Proxy ARPConfiguring the Communication Port 24. Communication Port Options 1Character Length Login Required 24. Communication Port Options 2Parity Stop Bits24. Communication Port Options 3 24. Communication Port Options 4 RIPConfiguring the Modem Port 10024. Communication Port Options 5 25. Modem Port Options 1101 25. Modem Port Options 2102 25. Modem Port Options 3103 25. Modem Port Options 4Configuring the Criteria for Automatic Backup Main Menu → Configuration → Auto Backup Criteria26. Auto Backup Criteria Options 1 10426. Auto Backup Criteria Options 2 When Auto Backup AllowedBackup Allowed Day From nnnn Backup Allowed Day To nnnn106 Configuring the FrameSaver SLV Router FrameSaver SLV Router Overview Network InterfaceEthernet Address Resolution Protocol IP RoutingProxy ARP Interface Configuration Network Address Translation IP Options ProcessingApplications Supported by NAT NAT Configuration Example NAT Mapping Public IP Addresses Private IP AddressesSave exit Napt Configuration Example Network Address Port TranslationNapt Mapping Public IP Address Private IP Addresses Access-list 1 permit 10.1.3.0 Ip nat inside source list 1 interface se 0.x overloadInt ethernet 0 ip nat inside int serial 0.x ip nat outside NAT and Napt Configuration Example Ip nat inside source static 10.1.1.1Dynamic Host Configuration Protocol Server Dhcp Server with NAT Configuration Example Public IP Addresses for NAT Private IP AddressesDhcp Server at Remote Site Configuration Example Dhcp Relay AgentRouter Security IP Router FilteringBridge Filtering Provisioning the Router Interface IP FilteringLand Bug Prevention Smurf Attack PreventionConfiguring the Router Using Terminal Emulation Security and Logins Limiting Access Controlling Asynchronous Terminal AccessSet the configuration option Limiting Dial-In Access via the Modem Port Controlling Isdn Access Disabling Isdn AccessIsdn Call Security Controlling Telnet or FTP Access Limiting Telnet AccessLimiting FTP Access Has a Level-1 login and Level-2 telnet access has Controlling Snmp Access Disabling Snmp AccessAssigning Snmp Community Names and Access Levels Limiting Snmp Access Through IP Addresses Main Menu → Configuration →General Snmp Management → Snmp Management Enable Management and Communication →Creating a Login Main Menu → Control→ Administer LoginsField Enter Modifying a Login Deleting a LoginControlling Router CLI Access Access Levels Command ModesLargo Changing Access Levels EnableEnable password password EndSecurity and Logins September Operation and Maintenance Operation and Maintenance Displaying System Information Main Menu → Status → IdentityView this field To find Viewing LEDs and Control Leads Isdn DBMFrameSaverTM SLV FrameSaver SLV 9126 LEDs and Control LeadsMain Menu → Status → Display LEDs and Control Leads Display LEDs & Control Leads Screen for a FrameSaver SLVFrameSaver SLV 9128-II LEDs and Control Leads Main Menu → Status → Display LEDs and Control LeadsLED Descriptions General Status LEDs 1Label Indiction Color What It Means ALMGeneral Status LEDs 2 ContdModel 9128-IINetwork, DSX, or PRI Interface LEDs Label Indication Color What It MeansUser Data Port LED CSU/DSUs Only Ethernet Port LED Routers OnlyControl Lead Descriptions Additional Control Leads Label Indication What It MeansNetwork Interface User Data PortDevice Messages Device Messages 1 What It Indicates What To DoSeen at an FTP TerminalDevice Messages 2 What It Indicates What To Do See Changing Software onDevice Messages 3 What It Indicates What To Do PVCDevice Messages 4 What It Indicates What To Do Reset COM Port usage Device Messages 5 What It Indicates What To DoFrameSaver SLV II onlyDevice Messages 6 What It Indicates What To Do Status Information Status Menu ExampleLast System Reset Date and Time System and Test Status MessagesMain Menu → Status → System and Test Status Self-Test Results MessagesChange Operating Mode Health and Status MessagesHealth and Status Messages 1 What It Indicates Isdn PRI DBM onlyHealth and Status Messages 2 What It Indicates Frame relay link 1,2FrameSaver SLV 9126-II or Health and Status Messages 3 What It Indicates Health and Status Messages 4 What It Indicates Framerelaylink 1,2Series Access Carrier only Health and Status Messages 5 What It IndicatesPathIP Address Down Nnnn, framerelaylink 1,2Health and Status Messages 6 What It Indicates Configuration→ Time Slot Assignment → Frame Health and Status Messages 7 What It IndicatesRelay Network Assignments and an LMI failure is Test Status Messages Test Status Messages 1 What It IndicatesDclb Active, framerelaylink 1 or Framerelaylink 1 ,3Test Status Messages 2 What It Indicates Network LMI-Reported DLCIs Status Main Menu → Status→ LMI Reported DLCIsLMI-Reported DLCIs Status Screen Example Tframe relay network, or IP Path Connection Status Main Menu → Status→ IP Path Connection StatusIP Path Connection Status Screen Example 11. IP Path Connection Status Field What It Indicates PVC Connection Status Main Menu → Status→ PVC Connection StatusPVC Connection Status Screen Example 12. PVC Connection Status 1 Field What It Indicates MgmtPVCNameEdlci 12. PVC Connection Status 2 Field Status What It IndicatesTime Slot Assignment Status Displaying Network Time Slot AssignmentsMain Menu → Status→ Timeslot Assignment Status → Network Network Timeslot Assignment Status Screen ExampleCross Connect Status Field bottom Indicates Displaying DSX-1 Time Slot AssignmentsMain Menu → Status→ Timeslot Assignment Status→ DSX-1 DSX-1 Timeslot Assignment Status Screen ExampleDBM Interface Status Main Menu → Status→ DBM Interface StatusDBM Interface Status Screen Example 13. DBM Interface Status 1 Field What It Indicates Invalid Call ID is displayedLink Name Disabled 13. DBM Interface Status 2 Field What It IndicatesAwarded and Being Delivered In Est Chnl-713. DBM Interface Status 3 Field What It Indicates Value is Call AwardedBeing Delivered In Est Chnl-7Most Recent and Previous Cause Value Messages Make sure the network is Operation and Maintenance Normal class applies for this Correct number Operation and Maintenance IP Routing Table Main Menu → Status→ IP Routing TableIP Routing Table Screen Example 15. IP Routing Table Values 1 Column What It Indicates15. IP Routing Table Values 2 Column What It Indicates TTLPerformance Statistics Main Menu → Status→ Performance StatisticsPerformance Statistics Menu Clearing Performance Statistics Service Level Verification Performance Statistics 17, SLV Performance Statistics for IP Enabled DlciVerification Options, in , Configuration Options, must Verification Options, in , Configuration Options, over Service Definitions in , Configuration Options COS IDSize is changed, a new average is not available until a new Dlci Performance Statistics Main Menu → Status → Performance Statistics→ Dlci18. Dlci Performance Statistics 1 What It Indicates 18. Dlci Performance Statistics 2 What It Indicates Additional Performance Statistics for IP Enabled Dlci Frame Relay Performance Statistics Main Menu → Status → Performance Statistics→ Frame RelayFor FrameSaver units with an Isdn DBM 20. Frame Relay Performance Statistics 1 What It IndicatesFrame Relay Errors 20. Frame Relay Performance Statistics 2 What It Indicates20. Frame Relay Performance Statistics 3 What It Indicates Frame Relay LMIFrame Relay Hdlc Errors 20. Frame Relay Performance Statistics 4 What It IndicatesESF Line Performance Statistics Main Menu → Status → Performance Statistics→ ESF LineTo select intervals You must enter an interval or time on ESF Line Performance Statistics Screen Example LofcUAS LofcDBM Call Performance Statistics 22. DBM Call Performance Statistics What It IndicatesEthernet Performance Statistics Main Menu → Status → Performance Statistics → Ethernet23. Ethernet Performance Statistics What It Indicates Trap Event Log Main Menu → Status → Trap Event LogTrap Event Log Screen Example Activating the Modem PassThru Feature Canceling Modem PassThru OperationMain Menu → Control→ Enable Modem PassThru to COM Main Menu → Control→ Disable Modem PassThru to COMManually Disconnecting the Modem Verifying Modem OperationMain Menu → Control→ Disconnect Modem Forcing Backup Disruptive Isdn DBM OperationPlacing a Test Call Nondisruptive Main Menu→ Test→ Isdn Call/PVC TestsIf the Result is Then Verifying That Backup Can Take Place Verifying Isdn LinesSystem Operational should appear FTP File Transfers Command Definition Upgrading System Software If the message displayed is ThenUpgrading Isdn BRI DBM Software Main Menu → Status→ IdentityDetermining Whether a Download Is Completed Changing SoftwareMain Menu → Control→ Select Software Release Transferring Collected Data If retrieving HenTurning Off the System Alarm Relay Main Menu → Control→ System Alarm Relay Cut-OffOperation and Maintenance September Troubleshooting Problem Indicators Indicators SeeOperation and Maintenance Main Menu → Status → Display LEDs and Control LEDsResetting the Unit and Restoring Communication Resetting the Unit from the Control MenuResetting the Unit By Cycling the Power Restoring Communication with an Improperly Configured Unit If selecting He following occursTroubleshooting Management Link Feature LMI Packet Capture Utility FeatureLMI Packet Capture Utility→ Display LMI Trace Log LMI Trace Log ExampleAlarms Alarm Conditions 1 What It Indicates What To DoMenu → Control → Reset Device Alarm Conditions 2 What It Indicates What To Do Main Menu → Configuration → Isdn → Link ProfilesName IPAddressAlarm Conditions 3 What It Indicates What To Do Menu→ Configuration→LMI Down, frame relay LinkAlarm Conditions 4 What It Indicates What To Do DTEAlarm Conditions 5 What It Indicates What To Do PathIP AddressAlarm Conditions 6 What It Indicates What To Do Nnnn , frame relayAlarm Conditions 7 What It Indicates What To Do Troubleshooting Tables Device ProblemsDevice Problems 1 Symptom Possible Cause Solutions Viewing the Trap Event LogDevice Problems 2 Symptom Possible Cause Solutions Improperly Configured Unit onFrame Relay PVC Problems Frame Relay PVC Problems Symptom Possible Cause SolutionsIsdn DBM Problems Isdn DBM Problems Symptom Possible Cause SolutionsMain Menu → Status → DBM Interface Status Tests Available Test Menu ExampleTest Timeout Feature DBM TestsWhen the status of a test is Only command available is Starting and Stopping a TestAborting All Tests PVC Tests PVC Tests Screen ExamplePVC Loopback Main Menu → Test→ Network PVC TestMain Menu → Test→ Data Port PVC Tests Main Menu → Test→ Isdn Call/PVC TestsSend Pattern Monitor PatternNetwork PVC Tests/Data Port PVC Tests Isdn Call/PVC TestsConnectivity Test CallPhysical Tests Physical Tests Screen ExampleLine Loopback Main Menu → Test→ Network Physical TestsLLB Payload Loopback PLBRepeater Loopback RLB AISDTE Loopback Main Menu → Test→ Data Port Physical TestsDSX Dtlb DTESend Line Loopback Data Channel Loopbacks on a Frame Relay Link Send Remote Line Loopback Main Menu → Test→ Network Physical Tests/PRI Physical TestsSend and Monitor Pattern Tests QrssIP Ping Test Ping Screen ExamplePing Options 1 Target IP AddressInter-Ping Delay Ping Options 2Source IP Address Packet SizeResponse Timeout Ping Options 3Ping Responses Field Possible Values Description IP Ping Test Procedure Main Menu → Test→ IP PingLamp Test Main Menu → Test→ Lamp TestHis chapter includes Setting Up the OpenLane SLM System OpenLane Support of FrameSaver DevicesSetting Up FrameSaver Support Ordering SLM Feature Set Activations To Find Your License Key NumberActivation Certificate Administering and Managing SLM Activations Entering an Activation Certificate Checking Activation Certificate StatusScheduling Activations Canceling Scheduled Activations Accessing and Printing the Certificate Summary ReportChecking the Status of Scheduled Activations 9128-A2-GB20-80 Setting Up NetScout Manager Plus for FrameSaver Devices 10-1Alarms Preparation10-2 PropertiesConfiguring NetScout Manager Plus 10-310-4 Verifying Domains and Groups 10-5Correcting Domains and Groups 10-6Property Description Setting 10-7Adding SLV Alarms Using a Template 10-8Editing Alarms 10-910-10 Adding SLV Alarms Manually 10-1110-12 Field Select or EnterParadyne Creating History Files 10-1310-14 Change 1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI toInstalling the User-Defined History Files Dvuhist -f Dallas51 3 config 30 60 Dallas51k.udhDvuhist -f Dallas51 301 3 config 30 60 Dallas301.udh 10-15Monitoring a DLCI’s History Data 10-1610-17 Monitoring the Agent Using NetScout Manager Plus 10-1810-19 Statistical Windows Supported 10-20Traffic Statistics Protocol Statistics Setting Up Network Health for FrameSaver Devices 11-1Installation and Setup of Network Health 11-2Discovering FrameSaver Elements 11-3Configuring the Discovered Elements 11-4Grouping Elements for Reports 11-5About Service Level Reports Generating Reports for a GroupAbout At-a-Glance Reports 11-6Reports Applicable to SLV Devices About Trend ReportsPrinted Reports 11-711-8 11-9 FrameSaver SLV Plus At-a-Glance Report11-10 Menu Hierarchy MenusStatus Easy Install Menu Hierarchy September Snmp MIBs and Traps, and Rmon Alarm Defaults MIB Support Downloading MIBs and Snmp TrapsSystem Group mib-2 Interfaces Group mib-2FrameSaver Unit’s sysDescr system FrameSaver Unit’s sysObjectID systemFrame Relay Logical Layer NAM Profile Link NameFR Service T1 FR NAM NetScout Indexes to the Interface Table ifTableFR DTE T1 FR NAM Rmon Logical Layer IfName of the interfaceNumber Dlci number ALL Number Dlci number DTEStandards Compliance for Snmp Traps ExamplesTrap authenticationFailure Trap warmStartTable B-3. warmStart Trap What It Indicates Possible Cause Variable-BindingTraps linkUp and linkDown Physical Sublayer PRIMIB StringsBRI Logical Link SublayerTraps enterprise-Specific Xxx.xxx.xxx.xxx , COS nnNnnn ’ ‘Path xxx.xxx.xxx.xxx UpThat the secondary clock source Traps RMON-Specific Trap dialControl Standard Dial Control MIBRmon Alarm and Event Defaults Event DefaultsEventIndex EventDescription EventType EventCommunity Dial Control Extension MIBPhysical Interface Alarm Defaults Rising Event OperationFrame Relay Link Alarm Defaults Snmp MIBs and Traps, and Rmon Alarm Defaults Dlci Alarm Defaults Paradyne Area MIB FR DTE MIB RFCDlci Alarm Defaults NetScout Area OID Rx Dlci Link Object ID Cross-References Numeric Order 6.1.2.1.2.2.1 6.1.2.1.2.10.32.2.16.1.2.1.16.12.2.1 MIB Rmon II RFC6.1.4.1.1795.2.24.2 6.1.4.1.1795.2.24.2.6.9.4Dlci CIR CIRDlci EIR 6.1.4.1.1795.2.24.2.6.9.4.4.2 6.1.4.1.1795.2.24.2.6.9.4.5.2.16.1.4.1.1795.2.24.2.6.9.4.7.1 6.1.4.1.1795.2.24.2.6.9.4.10.3.1 6.1.2.1.10.18.9.1 6.1.2.1.10.32.2.16.1.4.1.1795.2.24.2.6.9.4 6.1.4.1.1795.2.24.2.6.9.4 CLI Commands Convention MeaningX.x XxxxxxxxxxxxRouter CLI Commands, Codes, and Designations Pager Command Access Control CommandsTable C-1. Pager Command Table C-2. Access Control CommandsConfiguration Commands Table C-3. Configuration CommandsConfigure terminal factory Example configure terminalInterface Commands Table C-4. Interface Commands 1Command Mode config, config-if, config-subif Example interface serial 132.53.4.2Table C-4. Interface Commands 2 Encapsulation encapsulation-type encapsulation-protocolExample ip address 132.53.4.2 Example encapsulation frame-relay ietfTable C-4. Interface Commands 3 No ip unnumbered nullNo frame-relay interface-dlci dlci-num Example ip unnumberedIP Routing Commands Table C-5. IP Routing CommandsNo ip routing No ip multicast-routingBridge Commands Table C-6. Bridge Commands 1Example bridge crb 1 route ip Table C-6. Bridge Commands 2 Command Mode config-if, config-subifNo bridge-group bridge-group Example no bridge-groupARP Commands Table C-7. ARP CommandsArp timeout time No arp timeout time Example arp timeoutNAT Commands Table C-8. NAT Commands 1Example ip nat translation timeout No ip nat inside outsideTable C-8. NAT Commands 2 Ip nat pool pool-name start-ip-addr end-ip-addrNetmask netmask prefix-length / prefix-length No ip nat pool pool-namestart-ip-addr end-ip-addrTable C-8. NAT Commands 3 Clear ip nat translationFrom previous Dhcp Server Commands Table C-9. Dhcp Server Commands 1No service dhcp No ip dhcp pool pool-nameTable C-9. Dhcp Server Commands 2 Default-router ip-address No default-router ip-addressDomain-name domain-name No domain-name domain-name Dns-server ip-address No dns-server ip-addressTable C-9. Dhcp Server Commands 3 Network network-numDhcp Relay Agent Commands Table C-10. Dhcp Relay Agent CommandsNo ip dhcp-server ip-address Example ip dhcp relay max-clientsFilter access-list Commands Table C-11. Filter Commands 1Access-list access-list-num permit deny No access-list access-list-numpermit denyTable C-11. Filter Commands 2 For Extended IP Access ListsTable C-11. Filter Commands 3 For Protocol Type Access ListsExample access-list 200 permit 0x200 range Table C-11. Filter Commands 4 No ip access-group access-list-1-199numin outDiagnostic Commands Table C-12. Diagnostic Commands 1Table C-12. Diagnostic Commands 2 Traceroute protocol dest-ipsource source-ip length bytesShow Commands Table C-13. Show Commands 1Show configuration Show arpTable C-13. Show Commands 2 Show configuration saved unsavedShow frame-relay map Show interface intf-type intf-num .sub-intf-numTable C-13. Show Commands 3 Show ip dhcp binding ip-addressShow ip nat translations Show ip route ip-addressTable C-13. Show Commands 4 Show ip trafficShow spanning-tree Ethernet Type Codes Table C-14. Ethernet Type Codes Hex 1 DescriptionTable C-14. Ethernet Type Codes Hex 2 Description Protocol and Port Designations Icmp DesignationsAll 3 n = Destination unreachable All 5 n = All redirects TCP Port Designations UDP Port Designations Router Command Line Summaries Shortcuts CLI SummariesShow Command Summary Table D-1. Show Commands FunctionIntf-type intf-num .sub-intf-num Access Control and System Level Command Summary Table D-2. Access Control and System Level Commands FunctionCLI Command Summary Table D-3. CLI Commands 1Clear counters intf-type intf-num .sub-intf-num Dns-serverip-addressTable D-3. CLI Commands 2 Encapsulation encapsulation-type encapsulation-protocolCLI Command Default Settings Connectors, Cables, and Pin Assignments Rear PanelsConnectors, Cables, and Pin Assignments Model COM Port Connector Signal Direction Pin #Pin # Signal Direction COM Port for 9126 and 9128-II 25-PositionCOM Port-to-PC Cable Feature No -F2-550 COM Port for 9128-II Carrier MountCOM Port Non-Keyed Position Modular Plug DB9 SocketCOM Port-to-Terminal/Printer Cable Feature No -F2-540 COM Port Non-KeyedPosition Modular Plug DB25 Plug COM Port AUX Port Signal DB25 Pin # Direction RJ45 Pin # COM Port AUX Port Signal DB25 Pin # DirectionCOM Port-to-Router Cables Cisco 2500 Series Router RJ45 JackCOM Port Console Port Signal DB25 Pin # Direction DB9 Pin # COM Port AUX Port Signal RJ45 Pin # Direction3COM Router DB9 Socket COM Port AUX Port Signal RJ45 Pin # Direction DB25 Pin # Gender Adapter/Changer LAN Adapter Converter and CablePlug-to-Modular Jack Converter Com Port Position DB25 Plug DTR RTSDTE Port Connector Direction Pin SocketStandard V.35 Straight-through Cable Standard V.35 Crossover CableMM NN PinDSX-1 Connector DSX-1 Adapter Feature No -F1-560Function Circuit Direction Pin Number Position DB15 Modular Plug Socket UnkeyedDSX-1 Port for 1-Slot 9128-II 15-Position T1 Network Cable Feature No -F1-500 T1 Mass Termination Cable Feature No -F1-500Function Circuit Line # Pin # Ethernet Port Connector Canadian T1 Line Interface Cable Feature No -F1-510Plug Unkeyed Modem Connector Isdn DBM ConnectorIsdn Modular Cable Connectors, Cables, and Pin Assignments September Table F-1. NAM Technical Specifications 1 Criteria Physical DimensionsApprovals Physical EnvironmentTable F-1. NAM Technical Specifications 2 Criteria Table F-1. NAM Technical Specifications 3 Criteria Isdn PRI DBM InterfaceB8ZS Ethernet PortPower Consumption Dissipation Isdn BRI DBM Interface BRI, NI-1Ethernet Port FrameSaver AC Power Requirements Typical Power ConsumptionHeat Dissipation Max Switch Compatibility Service SupportedSwitched Network Interface Standards ComplianceFraming Format Coding FormatLine Build-Out LBO Model/Feature EquipmentDescription Number FrameSaver SLV UnitsEquipment List Isdn PRI DBM FrameSaver SLM Feature Set Upgrade Optional FeaturesPower Supplies NMS ProductsSeries Access Carrier 9128-II NAM only Description Part Number Feature Number CablesIndex IN-1IN-2 BecnCLI IN-3 DhcpIN-4 DBMIN-5 EEREIR IN-6 IN-7 LANIP SLV IN-8 LOFLOS IN-9 NMSIN-10 OIDIN-11 PortIN-12 IN-13 IN-14 IN-15 IN-16