Monitoring the Unit
Front Panel LEDs
DSX-1-Compatible Unit
Upon power up, the first three LEDs blink in sequence, indicating a successful start configuration. The green PWR LED lights whenever power is applied to the board. Loop LEDs blink until the loop has been synchronized and then remain off.
T1 HDSL
TERMINALNETWORK
SYSTEM
HDSL
TM
Local Remote | Loop | Bk |
|
PWR FAIL
AB
Loop Loop
TM
7900
7900
LED
Meaning
Local | ON: The local T1 interface has a loss of signal. |
|
|
Remote | ON: The remote T1 interface has a loss of signal. |
|
|
Loop Bk | ON: A loopback has been initiated for testing the equipment connected to |
| this unit. Refer to Chapter 7, Testing, for more information. |
|
|
PWR | ON: Power is applied to the unit. |
|
|
FAIL | ON: The processor has halted and repairs are required. |
|
|
Loop A | ON: HDSL Loop A has failed. |
| Blinking: HDSL Loop A is synchronizing with the |
| when the units are coming up after a reset). If the LED blinks for more |
| than 60 seconds, loss of signal has occurred. |
| Off: Loop A is enabled and synchronized. |
|
|
Loop B | ON: HDSL Loop B has been disabled (only Loop A is in use) or has |
| failed. |
| Blinking: HDSL Loop B is synchronizing with the |
| when the units are coming up after a reset). If the LED blinks for more |
| than 60 seconds, loss of signal has occurred. |
| Off: Loop B is enabled and synchronized. |
|
|
October 1997 |