Configuration Option Tables
Network Interface Options Menu
For Network Interface Options, refer to Table
Interface Options screen, follow this menu selection sequence:
Main Menu → Configuration (Load Configuration From) →
Configuration Edit/Display → Network
Table A-2. Network Interface Options
Network-initiated DSU Loopback (64K CC)
Possible Settings: Enable, Disable
Default Setting: Enable
Indicates whether the access unit responds to a DSU latching loopback sequence sent by the network as specified by TR62310.
H
Enable ± Responds to
Disable ± DSU will not respond to a DSU loopback initiated by the network.
Data Scrambling (64K CC)
Possible Settings: Enable, Disable
Default Setting: Disable
Data scrambling is used to suppress the possible simulation of
HData Scrambling (64K CC) option appears when Operating Mode is set to DDS in Table
Enable ± Enables data scrambling. The local and remote units must be set the same.
Disable ± No data scrambling.
V.54 Initiated DSU Loopback
Possible Settings: Enable, Disable
Default Setting: Disable
When enabled, user data is looped back to the network when a V.54 Loop Up sequence is received. The DSU loopback ends when a V.54 Loop Down sequence is detected.
Enable ± DSU loopback can be initiated or terminated by a remote unit sending
Disable ± V.54 Loop 2 sequences are ignored.
November 1997 |