Paradyne 7510 DSU manual Table A-3. Data Port Options 2, Carrier Control by RTS, Rlsd Control

Page 52

Configuration Option Tables

Table A-3. Data Port Options (2 of 3)

Carrier Control by RTS

Possible Settings: Constant, Switched

Default Setting: Constant

Simulates Constant or Switched Carrier operation.

Constant ± The internal RTS is forced on and the DSU is in a constant Data Mode on the transmit line. The external RTS lead is ignored. The actual signal on the line is either all ones (DMI) or DTE transmitted data.

Switched ± RTS is monitored and CMI codes are transmitted when RTS is off.

CTS Control

Possible Settings: Standard, Follow RTS, Forced On, Circuit Assurance

Default Setting: Standard

Specifies the operation of the Interchange Circuit CT106, Clear to Send (CTS), which is an output from the DSU.

Standard ± CTS follows the internal RTS with a fixed delay, except that CTS will be off when a network interface related alarm is detected or a test is active. The active test may be initiated locally, remotely, or by the network.

Follow RTS ± CTS follows the external RTS lead without delay, regardless of alarms and tests.

Forced On ± CTS is always forced on after the unit is powered up with a successful self-test.

Circuit Assurance ± With circuit assurance, CTS operates the same as the Standard option, except that CTS will also be deasserted when CMI codes are being received.

RLSD Control

Possible Settings: Standard, Forced On

Default Setting: Standard

Specifies the operation of the Interchange Circuit CT109, Received Line Signal Detector (RLSD or CD), which is an output from the DSU.

Standard ± RLSD is asserted when Data Mode is on the receive line. RLSD deasserts when a DDS facility alarm is detected or the DSU is receiving CMI codes.

Forced On ± RLSD is forced on after the unit is powered up with a successful self-test.

DSR Control

Possible Settings: Standard, Forced On, On During Test

Default Setting: Standard

Specifies the operation of the Interchange Circuit CT107, Data Set Ready (DSR), which is an output from the DSU.

Standard ± DSR is always asserted, except when a DDS facility alarm is reported or the DSU is in Test mode.

Forced On ± DSR is forced on after the unit is powered up with a successful self-test.

On During Test ± DSU operates the same as the Standard option, except that DSR remains asserted when the DSU is in Test mode to allow the DTE to send test patterns.

A-6

November 1997

7510-A2-GB20-10

Image 52
Contents Model 7510 DSU Copyright  1997 Paradyne Corporation All rights reserved Contents Monitoring the DSU Configuration Option Tables IndexDocument Purpose and Intended Audience About This GuideDocument Summary Product-Related Documents Model 7510 DSU Startup InstructionsModel 7510 DSU Features About the DSUFrame Typical DSU ConfigurationsRouter Relay Network User Interfaces Rear Panel InterfacesModem TerminalUsing the Asynchronous Terminal Interface Connecting to the Terminal PortSelect Initiating an ATI SessionMain Menu Status Test Configuration Control Load From Screen Format TypesWhat Affects Screen Displays Use the screen formatScreen Work Areas Menu PathKeyboard Keys Navigating the ScreensPress Screen Function Keys For the screen Select Press Return to FunctionSwitching to the Screen Function Key Area ExampleEnding an ATI Session Customizing the DSU Identifying the Device and SystemMain Menu → Control → Device Name Device NameSaving Configuration Options If you select ThenConfiguring the DSU Configuration Option AreasAccessing and Displaying Configuration Options Configuration Option Area Configuration Option SetMonitoring the DSU What to MonitorMain Menu → Status → System and Test Status Viewing System and Test StatusSystem and Test Status Health and Status SELF-TEST Results Health and Status HhhmmssSelf-Test Results Self-Test Results Messages What Message Indicates What To DoTest Status Messages Test Status Messages MeaningViewing Network Interface Status Main Menu → Status → Network Interface StatusViewing Network Performance Statistics Network Performance StatisticsAlarm Test DM OOS OOF NS TXD RXD RTS CTS DTR Monitoring the LEDsMain Menu → Status → Display LEDs Display Leds System NetworkAlarm System LEDsDM ± Data Mode OOS ± Out of ServiceNS ± No Signal Network LEDsPort LEDs Testing Accessing the Test MenuMain Menu → Test TestDevice Messages Loopback Type Initiated By Table A- 2, Network Interface OptionsMain Menu → Test → Network Tests Running Network TestsNetwork Tests CSU or External Network Loopback DSU or Internal Network Loopback Send V.54 Up/Down SequencesTest Pattern for the Network Main Menu → Test → Data Port Tests Running Data Port TestsData Port Tests Local Loopback Test Pattern for the DTERunning the Lamp Test Main Menu → Test → Lamp TestEnding an Active Test Messages and Troubleshooting Messages and TroubleshootingResponding to Device Messages Device Messages 1 What Message Indicates What To DoDevice Messages 2 What Message Indicates What To Do Troubleshooting Troubleshooting 1 Symptom Possible Cause SolutionsResetting the DSU Troubleshooting 2 Symptom Possible Cause SolutionsMain Menu → Control → Reset Device Displaying DSU Identity InformationConfiguration Option Tables Select To Access To ConfigureOverview Status Load Edit/Display TestOperating Mode Lads Timing Possible Settings Internal, External, ReceiveSystem Options Menu Table A-1. System Options 1Test Timeout Table A-1. System Options 2Lads Line Rate Kbps Test Duration minNetwork Interface Options Menu Table A-2. Network Interface OptionsNetwork-initiated DSU Loopback 64K CC Data Scrambling 64K CCData Port Options Menu Table A-3. Data Port Options 1Invert Transmit Clock Bilateral LoopbackCarrier Control by RTS Table A-3. Data Port Options 2Rlsd Control Inactivity Timeout Terminal Port OptionsTable A-3. Data Port Options 3 Table A-4. Terminal Port Options 1Table A-4. Terminal Port Options 2 Disconnect TimeminutesConfiguration Option Settings Configuration WorksheetsWorksheets Network Interface Cables and Pin Assignments Terminal Port EIA-232 Connector Signal Direction Pin #Signal User Data Port ConnectorNumber Direction Pin Socket Connector Standard EIA-232-D Crossover Cable PinLAN Adapter Converter and Cable Modular RJ48S DDS Network Interface CableRJ48S DDS Network Interface Cable Functions Circuit Pin # Cable Plug to Modular Jack LAN AdapterTechnical Specifications Table D-1. Model 7510 DSU Technical Specifications 1Table D-1. Model 7510 DSU Technical Specifications 2 Network InterfaceNetwork Compatibility DTE Data Port InterfaceGlossary Factory defaults EIA-232Excessive BPV Frame relayReset MultiplexingNode Non-latchingIndex NumbersIN-2 IN-3