Model 3101RC Getting Started Guide3 • Configuration
local:%configure
local:(conf)#runningcfg write partition 1
Are you sure write running configuration to Flash ROM partition #1 ? (Y/[N])y System writing Flash ROM partition #1...
Write running configuration to Flash ROM partition #1 success! local:(conf)#exit
local:%ping 172.16.10.72
PING 172.16.10.72 (172.16.10.72): 56 data bytes
64 bytes from 172.16.10.72: icmp_seq=0 ttl=64 time=8.7 ms
64 bytes from 172.16.10.72: icmp_seq=1 ttl=64 time=0.8 ms
64 bytes from 172.16.10.72: icmp_seq=2 ttl=64 time=0.8 ms
64 bytes from 172.16.10.72: icmp_seq=3 ttl=64 time=0.8 ms
4 packets transmitted, 4 packets received, 0% packet loss
local:%
Now you can access the Model 3101 via Telnet on port 23 (for using CLI) or Web GUI interface by entering the IP address of 3101 in your browser's URL/address field.
Web GUI
Use the following commands to provision an IP port in the Web GUI:
1.On the menu tree, click on System > Board Setup. The Board Setup page is displayed.
Figure 10. Board IP Setup
2.Type in new IP setting in the GBE (In Band) section for
3.Type in new IP setting in the MGMT (Out Band) section for
4.Click on Modify to submit the modification.
Provisioning a Management IP Port | 23 |