Patton electronic 2621, 2635 manual IPLink Series High Speed Routers overview, General attributes

Page 18

Models 2603, 2621, and 2635 Getting Started Guide

1 • General Information

 

 

IPLink Series High Speed Routers overview

The IPLink Series of gateway routers/bridges combine full set of high-speed IP routing features and WAN access via PPP/IP/FR protocols. All IPLink routers come with an auto-sensing full-duplex 10/100Base-T Ethernet port, MDI-X cross-over switch, console port, and internal or external power supply. There are three versions in the IPLink series corresponding to a choice of WAN interface:

The Model 2603 is equipped with an integrated T1/E1 CSU/DSU for connection to full and fractional T1/ E1 services.

The Model 2621 is equipped with DTE/DCE user configurable X.21 interface.

The Model 2635 equipped with a V.35 interface presented on a female DB-25 connector and a cable to convert to an M34/F.

The IPLink routers provide selectable bridging or routing functionality along with advanced IP features such as NAT/NAPT, Firewall, and DHCP. A complete set of configurable PPP/IP/FR WAN protocols allow a wide range of choices when connecting branches via common WAN services. The IPLink routers boast easy installa- tion offering Console/VT-100, Telnet, HTTP, and SNMP management options.

The following sections describes the IPLink series features and capabilities:

General attributes, see section “General attributes”

Ethernet, see section “Ethernet” on page 19

Protocol support, see section “Protocol support” on page 19

PPP support, see section “PPP Support” on page 19

Management, see section “Management” on page 19

WAN interface, see section “WAN Interfaces” on page 19

Security, see section “Security” on page 20

Front panel status LED see section “Front Panel Status LEDs and Console Port” on page 20

General attributes

Compact, low cost router/bridge

10/100 Ethernet

Comprehensive hardware diagnostics. Easy maintenance and effortless installation.

Plug-and-Play operation for fast and seamless turn-up with pre-configured WAN and LAN options.

Built-in web configuration.

Setup allows for standard IP address and unique method for entering an IP address and mask without requiring a console connection. Default IP address of 192.168.1.1/24.

Simple software upgrades obtained via FTP.

Front panel LEDs indicate Power, WAN, and Ethernet LAN speed and status.

Convenient and standard RJ connectors for Ethernet, Line, and Console.

Standard one-year parts and labor warranty.

IPLink Series High Speed Routers overview

18

Image 18
Contents IPLink Series High Speed Routers Mailsupport@patton.com Summary Table of Contents Contents Models 2603, 2621, and 2635 Getting Started Guide Remote Site Configuration Central site configuration EMC Ethernet Cable 123 Adapter Models 2603, 2621, and 2635 Getting Started Guide List of Figures Models 2603, 2621, and 2635 Getting Started Guide List of Tables About this guide AudienceStructure Precautions Safety when working with electricityImpaired functioning Factory default parameters General observationsTypographical conventions used in this document General conventionsChapter contents General InformationIPLink Series High Speed Routers overview General attributesPPP Support EthernetProtocol support WAN InterfacesLogging or Smtp on events POST, Post errors, PPP/DHCP, IP SecurityFront Panel Status LEDs and Console Port Rear panel connectors and switches Console portOn the rear panel from left to right are the following Power connector Ethernet port outlined in greenGeneral Information Product Overview Introduction Applications Overview Sync Serial ApplicationInitial Configuration Hardware installation Interface cable installationWhat you will need RJ-48C pinout diagram Initial Configuration Ethernet connector Interface connector RJ-45 DB-15 Case being opened with a screwdriver Ethernet connector Interface connector RJ-45 DB-25 Installing the AC power cord DCEInitial Configuration Installing the Ethernet cable Do the followingWeb Operation and Configuration IP address modificationIP address has now been successfully changed PC ConfigurationModel 2603 home Model 2635 home Ethernet LAN Port LAN Connections Ethernet PortBasic Ethernet port attributes Configurable Ethernet parameters Serial Port Configuration WAN Serial Port Configuration Serial InterfaceVariables Web Interface Configuration T1/E1 Interface ConfigurationConfiguring the IPLink Series 2603 for T1 Operation Web Configuration , enter username See figureLine Options Fractional T1 Configuring the IPLink Series 2603 for E1 OperationSerial Port Configuration WAN Services PPP BridgedWAN Services WAN Service Configuration PPP ConfigurationPPP Bridged Leave User name and Password blank. Click on Create PPP Routed Remote site configurationClick on Create PPP Routed Configuration menuClick the Update button Edit IP address of WAN portPPP link status Username blank Password blank Click on the Create button LMI Management Frame Relay linksLMI Configuration Web Configuration Methods Frame Relay Configuration Dlci Number UseFrame Relay bridged Frame Relay bridged creationCentral site configuration Frame Relay Routed RelayDescription FR routed Frame Relay Channel Routed configuration Cost Interface frame-0 IP route for Frame Relay routed applicationWAN Services Security Click on Create a new service Configuring the routerClick on the Create a new Ip route... hyperlink Configuring the security interfaces Valid gateway routeSecurity configuration home Configuring Security Policies Click on the hyperlink New Policy... See figureEnabling the Firewall Firewall PortfiltersDeleting a security Policy Security Triggers You can now ping between the two networksConfiguring TCP port filter for FTP Adding trigger for FTP data transfer Intrusion Detection System IDS Attack Name Protocol Attacking Host Blacklisted?Security Introduction to NAT Enabling NATGlobal address pool and reserved map Click on Add Global Address Pool button Dhcp and DNS Configuration Services and features normally associated with each other Dhcp Server NATDhcp Server web Parameters for the Dhcp Server subnet Dhcp server configuration webIP Addresses to be available on this subnet Next section see figure 58. has three parametersExample based on default range of IP address pool DNS server option informationDhcp Relay Default gateway option informationAdditional option information Configuration of the Dhcp RelayDhcp Relay webpage DNS Relay Configuring the DNS RelayDNS Relay configuration webpage IP Services WEB Server IP ServicesNext command disables the WEB server CLI ConfigurationAssociated Ports for the different System IP Services System Configuration Authentication Authentication web page showing default superuserAlarm Access the configuration and status of the alarmsRemote Access Alarm & Alarm Error Log configurationUpdate Backup/RestoreSave Website Settings RestartError Log Snmp DaemonSystem Tools Snmp Daemon configurationSntp Client Configuration Sntp Client Mode Configuration Parameters Configuring the Sntp ClientSystem Clock Setting Sntp Client General Configuration ParametersConfiguration of the internal system calendar clock System Status System Status Port Connection StatusWAN Status LAN StatusMAC address the MAC address of the Ethernet port Hardware StatusStatus LEDs Contacting Patton for assistance Warranty coverage Contact informationPatton support headquarters in the USA Return for credit policy Out-of-warranty serviceReturns for credit RMA numbersAppendix a Compliance information EMCCE Declaration of Conformity ComplianceRadio and TV Interference FCC Part FCC Part 68 Acta Statement Model 2603 onlyIndustry Canada Notice 2603 Model only Appendix B Specifications Sync Serial Interface General CharacteristicsEthernet T1/E1 InterfaceProtocol Support PPP SupportManagement AC universal power supply DimensionsPower and Power Supply Specifications VDC power supplyAppendix C Cable Recommendations Ethernet Cable AdapterAppendix D IPLink Physical Connectors Assuming the MDI-X switch is in the out position RJ-45 shielded 10/100 Ethernet portRJ-45 non-shielded RS-232 console port EIA-561 35 M/34 and DB-25 Connector Serial port21 DB-15 Connector Pin No Circuit Signal Name DirectionE1/T1 RJ-48C Connector Pin No SignalAppendix E Command Line Interface CLI Operation Produces a list of numbered transport objects Using the ConsoleCLI Terminology Local VT-100 emulationAnother example shows when the user must provide a parameter ThenEnter the new password twice as prompted Administering user accountsSetting user passwords Adding new usersControlling user access Changing user settingsControlling login access For example, to change the security level for fred, enter
Related manuals
Manual 133 pages 54.65 Kb