Patton electronic 2621, 2635 manual Dce, Installing the AC power cord

Page 34

Models 2603, 2621, and 2635 Getting Started Guide

3 • Initial Configuration

 

 

Note The IPLink comes with a V.35 cable configured as a tail-circuit. Use this cable to interconnect the IPLink’s V.35 port to a device configured as

a DCE.

2635 IPLink

Power

10/100

 

 

Crossover

 

Ethernet

 

MDI-X

 

 

X.21

 

WAN

 

Interface

 

 

 

 

Modem

V.35

 

 

 

 

 

 

 

 

Use cable provided

 

 

 

 

 

 

 

 

 

 

DCE

with 2635 IPLink

 

 

 

 

 

 

 

 

 

Figure 11. Connecting the 2635 to a DCE device

The serial port on the IPLink Model 2635 is configured as a DCE, it connects directly to a DTE using a stan- dard straight-through V.35 cable.

However, in many applications, the IPLink’s V.35 interface will connect to a DCE (modem or multiplexer), in this situation use the special cable provided with your Model 2635. This DB-25/M35 cable presents the 2635’s V.35 interface as a DTE for direct connection to a DCE (see figure 11).

Installing the AC power cord

The IPLink router comes with an internal or external power supply. This section describes installing the power cord into the IPLink router. Do the following:

The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt- age, current, anticipated temperature, flammability, and

CAUTION mechanical serviceability.

Note Do not connect the other end of the power cord to the power outlet at this time.

1.If your unit is equipped with an internal power supply, go to step 2. Otherwise, insert the barrel type con- nector end of the AC power cord into the external power supply connector (see figure 12).

2.Insert the female end of the AC power cord into the internal power supply connector (see figure 12).

Hardware installation

34

Image 34
Contents IPLink Series High Speed Routers Mailsupport@patton.com Summary Table of Contents Contents Models 2603, 2621, and 2635 Getting Started Guide Remote Site Configuration Central site configuration EMC Ethernet Cable 123 Adapter Models 2603, 2621, and 2635 Getting Started Guide List of Figures Models 2603, 2621, and 2635 Getting Started Guide List of Tables Audience About this guideStructure Safety when working with electricity PrecautionsImpaired functioning Factory default parameters General observationsTypographical conventions used in this document General conventionsChapter contents General InformationIPLink Series High Speed Routers overview General attributesPPP Support EthernetProtocol support WAN InterfacesSecurity Logging or Smtp on events POST, Post errors, PPP/DHCP, IPFront Panel Status LEDs and Console Port Console port Rear panel connectors and switchesOn the rear panel from left to right are the following Power connector Ethernet port outlined in greenGeneral Information Product Overview Introduction Applications Overview Sync Serial ApplicationInitial Configuration Interface cable installation Hardware installationWhat you will need RJ-48C pinout diagram Initial Configuration Ethernet connector Interface connector RJ-45 DB-15 Case being opened with a screwdriver Ethernet connector Interface connector RJ-45 DB-25 Installing the AC power cord DCEInitial Configuration Installing the Ethernet cable Do the followingWeb Operation and Configuration IP address modificationIP address has now been successfully changed PC ConfigurationModel 2603 home Model 2635 home Ethernet LAN Port LAN Connections Ethernet PortBasic Ethernet port attributes Configurable Ethernet parameters Serial Port Configuration Serial Interface WAN Serial Port ConfigurationVariables Web Interface Configuration T1/E1 Interface ConfigurationConfiguring the IPLink Series 2603 for T1 Operation Web Configuration , enter username See figureLine Options Fractional T1 Configuring the IPLink Series 2603 for E1 OperationSerial Port Configuration WAN Services PPP BridgedWAN Services PPP Configuration WAN Service ConfigurationPPP Bridged Leave User name and Password blank. Click on Create PPP Routed Remote site configurationClick on Create PPP Routed Configuration menuClick the Update button Edit IP address of WAN portPPP link status LMI Management Frame Relay links Username blank Password blank Click on the Create buttonLMI Configuration Web Configuration Methods Frame Relay Configuration Dlci Number UseFrame Relay bridged Frame Relay bridged creationCentral site configuration Frame Relay Routed RelayDescription FR routed Frame Relay Channel Routed configuration Cost Interface frame-0 IP route for Frame Relay routed applicationWAN Services Security Click on Create a new service Configuring the routerClick on the Create a new Ip route... hyperlink Configuring the security interfaces Valid gateway routeSecurity configuration home Configuring Security Policies Click on the hyperlink New Policy... See figureFirewall Portfilters Enabling the FirewallDeleting a security Policy Security Triggers You can now ping between the two networksConfiguring TCP port filter for FTP Adding trigger for FTP data transfer Intrusion Detection System IDS Attack Name Protocol Attacking Host Blacklisted?Security Enabling NAT Introduction to NATGlobal address pool and reserved map Click on Add Global Address Pool button Dhcp and DNS Configuration Services and features normally associated with each other Dhcp Server NATDhcp Server web Parameters for the Dhcp Server subnet Dhcp server configuration webIP Addresses to be available on this subnet Next section see figure 58. has three parametersExample based on default range of IP address pool DNS server option informationDhcp Relay Default gateway option informationAdditional option information Configuration of the Dhcp RelayDhcp Relay webpage DNS Relay Configuring the DNS RelayDNS Relay configuration webpage IP Services WEB Server IP ServicesNext command disables the WEB server CLI ConfigurationAssociated Ports for the different System IP Services System Configuration Authentication Authentication web page showing default superuserAlarm Access the configuration and status of the alarmsRemote Access Alarm & Alarm Error Log configurationBackup/Restore UpdateSave Website Settings RestartError Log Snmp DaemonSystem Tools Snmp Daemon configurationSntp Client Configuration Sntp Client Mode Configuration Parameters Configuring the Sntp ClientSystem Clock Setting Sntp Client General Configuration ParametersConfiguration of the internal system calendar clock System Status System Status Port Connection StatusWAN Status LAN StatusMAC address the MAC address of the Ethernet port Hardware StatusStatus LEDs Contacting Patton for assistance Contact information Warranty coveragePatton support headquarters in the USA Return for credit policy Out-of-warranty serviceReturns for credit RMA numbersAppendix a Compliance information EMCCE Declaration of Conformity ComplianceRadio and TV Interference FCC Part FCC Part 68 Acta Statement Model 2603 onlyIndustry Canada Notice 2603 Model only Appendix B Specifications Sync Serial Interface General CharacteristicsEthernet T1/E1 InterfacePPP Support Protocol SupportManagement AC universal power supply DimensionsPower and Power Supply Specifications VDC power supplyAppendix C Cable Recommendations Ethernet Cable AdapterAppendix D IPLink Physical Connectors RJ-45 shielded 10/100 Ethernet port Assuming the MDI-X switch is in the out positionRJ-45 non-shielded RS-232 console port EIA-561 35 M/34 and DB-25 Connector Serial port21 DB-15 Connector Pin No Circuit Signal Name DirectionE1/T1 RJ-48C Connector Pin No SignalAppendix E Command Line Interface CLI Operation Produces a list of numbered transport objects Using the ConsoleCLI Terminology Local VT-100 emulationAnother example shows when the user must provide a parameter ThenEnter the new password twice as prompted Administering user accountsSetting user passwords Adding new usersControlling user access Changing user settingsControlling login access For example, to change the security level for fred, enter
Related manuals
Manual 133 pages 54.65 Kb