In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices.

Note: It’s not recommended using Ethernet cables outdoors. When cabling outdoors, please use a signal lightning arrester.

Requirements for Cabling Outdoors

Aerial cabling without safeguard is not allowed.

It’s not allowed cabling down the building to connect network devices in different floors.

Outdoor cables should be buried and paved to the indoor through basement. A piece of steel wire should be paved underground along the pipe and connected to the lightning protection terminal of the building for shielding. Before connecting the cable to the device, install a signal lightning arrester on the corresponding port.

When an aerial cable is set up, the cable should be through a metal pipe (15m long at least\ before coming into the building. The two ends of this metal pipe should be grounded. Before connecting the cable to the device, install a signal lightning arrester on the corresponding port.

It’s not necessary to pave STP cables through pipes. The shielded layer of STP cable should be well grounded. Before connecting the cable to the device, install a signal lightning arrester on the corresponding port.

Requirements for Cabling Indoors

When cabling indoors, keep a certain distance away from the devices that may cause high-frequency interferences, such as down-conductor cable, powerline, power transformer and electromotor.

The main cable should be paved in the metal raceway of the access shaft. When cabling, keep the loop area formed by the cable itself as small as possible.

10 Lightning Protection

Image 14
Contents Installation Guide Copyright & Trademarks FCC Statement Audience Contents Appearance CCCCCCCCCCCIntroductionProduct Overview Front PanelLEDs Front panel of TL-SG3424P is shown as the following figure Port Feature Rear PanelGrounding Terminal 2222Safety Precautions CCCCCCCCCCCInstallationPackage Contents Lightening Protection ClearnessElectromagnetic Interference Installation Site 2222Installation Tools2222Product Installation Desktop InstallationRack Installation Requirements for Cabling Outdoors CCCCCCCCCCCLightning ProtectionCabling Reasonably Requirements for Cabling IndoorsEthernet Cable 3333Connect to Ground Connecting to the Grounding BarConnecting to the Ground via the Power Supply 3333Equipotential Bonding 3333Use Lightning Arrester 4444SFP Port CCCCCCCCCCCConnectionEthernet Port 4444Console Port 4444Verify Installation4444Power On For TL-SG3210 Switch 4444InitializationCCCCCCCCCCCConfiguration Configure the Switch via GUI5555Configure the Switch Using CLI Logon by a Console PortSelect the port to connect in -6, and click OK Logon by Telnet Type cmd in the prompt Run window as -10 and click OK FFFFFFFFFFFFFLog in the Switch AAAAAAAAAAAATroubleshooting Qqqq Why does the Power LED work abnormally?AAAAAAAAAAAAHardware Specifications AAAAAAAAAAAATechnical Support L2 Managed Switch Tel +86 755 Mail support@tp-link.com 7106504453 REV2.0.0