3.Refer to the two tables below and enter the network IP values.

NOTE: If an invalid IP address is entered, the subnet mask may be CHANGED

AUTOMATICALLY BY THE EQUIPMENT to an appropriate subnet mask.

NOTE: To TURN OFF the TCP/IP stack, an IP address of 0.0.0.0 can be entered, no IP Mask or Default Router would be required.

 

SETTINGS FOR NETWORK WITH

 

NON-CRESTRON EQUIPMENT

 

Recommended Settings

IP Address

172.16.X.Y

IP Mask

255.255.0.0

Default Router

0.0.0.0

Class Ranges:

(X, Y and Z range from 0 to 255)

Class A: 10.X.Y.Z

Class B: 172.16.X.Y to 172.31.X.Y

Class C: 192.168.0.X to 192.168.255.X

Other Crestron IP control/CEN devices on this LAN would conform to similar parameters.

SETTINGS FOR NETWORK WITH

CRESTRON ONLY EQUIPMENT

If the CEN-CN is being placed on a corporate LAN or a LAN with other equipment besides Crestron equipment, the IP Address, IP Mask, and Default Router (also known as Gateway) will be provided from an MIS Department or other network administrator.

Other Crestron IP control/CEN devices on this network would require that their IP Address, IP Mask, and Default router also be obtained by the MIS department or other network administrator.

Reference Guidelines

First Octet of Zero and 127 are reserved.

Class A: First octet ranges from 1 to 126

Default Subnet Mask: 255.0.0.0

Class B: First two octets range from 128.1 to 191.254

Default Subnet Mask: 255.255.0.0

Class C: First three octets range from 192.0.1 to 223.255.254

Default Subnet Mask: 255.255.255.0

Class D: 224.0.0.0 to 239.255.255.254

(Not available for general use, reserved for multicast systems.)

Class E: 240.0.0.0 to 255.255.255.254

(Not available for general use, reserved for IAB use.)

4.On the “Set Control System IP Address” dialog box, click OK to set the entered values.

5.The reboot dialog box as shown on the next page opens. Click Yes to reboot the CEN-CN and continue.

Operations Guide - DOC. 5721

Ethernet/Cresnet Interface: CEN-CN 15

Image 19
Contents Page Crestron Contents Page Functional Description DescriptionCEN-CN Ports Physical DescriptionNET 12VDC .5 aPWR Leading SpecificationsCEN-CN Indicators EthernetSpecification Details Cresnet Network WiringInstalling Crestron Development Tools Configuration SetupHookup Diagram for Configuration Configuration Cable Fabrication SpecificationsObtaining Communications Communication via PC Port of CEN-CN Typical Connections When Configuring the CEN-CNVerifying Auto Baud Search Ethernet/Cresnet Interface Troubleshooting CommunicationsUpdating the CEN-CN 12 ∙ Ethernet/Cresnet Interface CEN-CN Operations Guide DOC Initial IP Setup Ethernet Configuration14 ∙ Ethernet/Cresnet Interface CEN-CN Operations Guide DOC Settings for Network with Changing the IP Table via Crestron Viewport IP Table SetupCrestron e-control IP Table Information Hookup Diagram for Normal OperationCommunicating via Ethernet CommunicationsTroubleshooting Communications via Ethernet Troubleshooting Problem SolvingSimpl Windows Example Program Further Inquiries Future UpdatesMerchandise Returns / Repair Service Return and Warranty PoliciesCrestron Limited Warranty CTP CIPNMS Trap Catcher IP IDIP MTU Master ListTCP/IP This page intentionally left blank Crestron CEN-CN Crestron Electronics, Inc Operations Guide DOC