Compaq R6000 manual Hardware Options, UPS Option Cards, Option Part Number

Page 18

1-8Compaq R6000 Series UPS Operation and Reference Guide

Hardware Options

Six options are available for the Compaq R6000 UPS.

Table 1-2

Hardware Options

Option

Part Number

 

 

Compaq Extended Runtime Module

347224-B21

 

 

Compaq SNMP-EN Adapter

347225-B21

 

 

Compaq Multi-Server UPS Card

123508-B21

 

 

Compaq Scalable UPS Card

123509-B21

 

 

Compaq PDU High Voltage Models

NA Only¾295363-002

 

INTL¾295363-B31

 

 

Compaq High to Low Voltage Transformer (250VA)

388643-B21

 

 

UPS Option Cards

Two option slots are available to further expand the capabilities of the Compaq R6000 UPS in both power control and server communication for networking environments.

Option kits include the Compaq Multi-Server UPS Card, the Compaq Scalable UPS Card and the Compaq SNMP-EN Adapter. These enhancements provide communication with multiple systems, multiple UPS units, and network management applications.

Image 18
Contents Compaq R6000 Series UPS Operation and Reference Guide Page Contents Operation Configuration Appendix B Symbols in Text About This GuideText Conventions Symbols on Equipment Viii Compaq R6000 Series UPS Operation and Reference GuideRack Stability Getting HelpCompaq Technical Support Compaq Website Compaq Authorized Reseller Compaq R6000 UPS Series Models IntroductionCompaq R6000 UPS Series Models UPS Model Part Number CommentsFront Panel R6000 front panelRear Panel Compaq R6000 UPS Features Communication Ports Solid green means normal operation Front Panel LEDs LED Meaning Flashing green means StandbyFront Panel Controls and LCD Display Control Name FunctionPower Management Software Compaq Power Management SoftwareUPS Option Cards Hardware OptionsHardware Options Option Part NumberOption Card Matrix CaseScalable Compaq Multi-Server UPS Card Multi-Server UPS CardCompaq Scalable UPS Card Scalable UPS CardCompaq SNMP-EN Adapter SNMP-EN AdapterPower Distribution Units PDUs Extended Runtime Modules ERMsWarranty Remote Emergency Power Off Repo Port$25,000 Computer Load Protection Guarantee Pre-Failure Battery Warranty Installation Important Safety Instructions About This DeviceInstallation Considerations WeightPosition Outline of Installation Procedure Check Battery Recharge Label Unpacking the UPSPreparing the Rack Assembling the Compaq R6000 UPS Placing UPS in rackPlacing chassis in rack Wiring the Compaq R6000 UPS 8Compaq R6000 Series UPS Operation and Reference Guide Connecting the Compaq R6000 UPS to AC Branch Circuit Risk of Fire Notice Electrical Safety RequirementsHigh Leakage Current Procedure RecommendationInput Wiring Removing terminal input block coverInstall and connect the battery packs Sliding battery packs into chassisConnect cables 11. Connecting battery packs to the Compaq R6000 UPS Attaching Front Top Bezel 12. Attaching the top front bezelInstalling Extended Runtime Modules ERMs Connecting Communications Ports Connecting Communication Ports to Other DevicesConnecting Loads Installing and Connecting Communication OptionsLoad Segments Description Load Effect on Backup Time Ordering Extra Power CordsConfiguring Load Segments Attaching the Load SegmentsCompleting the Assembly R6000 UPS in the Rack 16. Placing the battery circuit breaker in the on positionPressing the on button Powering up the R6000 UPSTurning on the Main Circuit Breaker Shutting Down the SystemInstallation is Now Complete Charging BatteriesOperation Front Panel Controls Front Panel Indicators Front Panel LCDFront Panel LEDs Ref # Description Standby Mode Modes of OperationBattery Mode Audible Alarm Initiating a Self-testSilencing an Audible Alarm Silencing an audible alarmConfiguration Changing Configuration ParametersMatching the Utility Voltage Voltage Ranges VACRange Configuring the Compaq R6000 UPS Using the LCD Display Menu LCD display, showing the three buttons that control itTop Level Main Menu Initial Power-Up DisplayLCD Display Menu Structure Sub-Menu ChoicesStatus UPS Status + Load Segment statusLoad Power Off UPS Status + Active Alarm CountOn Battery Load Power OnInput Volts MetersOverload Output VoltsBattery Volts Active AlarmsOutput Power Output FrequencyInput Over or Under Frequency Input AC Over VoltageInput AC Under Voltage Output OverloadBattery Totally Discharged Inverter FaultBattery Low UPS on BatteryBattery Data Battery Test FailedSite Wiring Fault Firmware Version Load Control Display TestSystem Setup Set Hardware HW ConfigurationBattery Setup Set LanguageSet Alarm Horn Set PasswordSerial Port Communications SetupSet Sync Range ±Hertz Baud RateData Bits Stop BitsParity Set Site Fault Set Sleep ModeSet Voltage Battery Maintenance Precautions When to Replace Batteries Obtaining New BatteriesHow to Replace Batteries Removing the Battery PacksBefore Replacing Batteries Place the battery circuit breaker in the OFF position Disconnecting the battery cables Slide out the Compaq R6000 UPS battery packs Installing New Batteries Test/Reset Alarm button Disposing of Used Batteries Care and Storage of BatteriesExtended Runtime Module ERM Batteries Troubleshooting Responding to Audible Alarms Audible Alarm GroupCauses Action Shutdown Imminent Causes Action Shutdown within SecondsLoads in Jeopardy Audible Alarm Causes Action Low, refer to Chapter6Compaq R6000 UPS Series Operation and Reference Guide Responding to Audible Alarms Audible Alarm Group Battery breaker is in the onCompaq R6000 UPS Trouble Indicators Trouble IndicatorsLED Alarm Configurations Repairing the UPS Regulatory Compliance Notices Federal Communications Commission NoticeClass a Equipment Class B EquipmentCanadian Notice Avis Canadien European Union NoticeJapanese Notice Taiwanese NoticeClass A/B Equipment Battery Replacement Notice Electrostatic Discharge Grounding Methods Specifications Table C-1 Physical Characteristics Physical SpecificationsInput Specifications Table C-2 Input SpecificationsOutput Specifications IV. Additional Features II. Output VoltageRegulation Battery Specifications Battery SpecificationsBattery Runtime Table C-4Environmental Specifications Table C-6 Environmental SpecificationsIndex Battery cable connectors Button controls Index Compaq 6000 Series UPS Operation and Reference Guide See Compaq 6000 Series UPS Operation and Reference Guide Replacement battery kit part Compaq 6000 Series UPS Operation and Reference Guide Options tabulated Compaq 6000 Series UPS Operation and Reference Guide