Compaq 380 manual Specifications

Page 18

IntelliStripe 380

SPECIFICATIONS

The Specifications are listed in Table 1-1.

 

Table 1.1. Specifications

 

 

 

OPERATING

MSR Read-data Format

Mag-Stripe: ANSI/ISO 7810, 7811/AAMVA/ for tracks 1, 2, and 3

Specifications Supported

Smart Card: ISO 7816-1, -2, and -3

Encode Coercivity

LoCo = 325 Oe +/- 75 Oe ( Range of 250 Oe to 400 Oe )

Ranges

HiCo = 2750 Oe +/- 500 Oe ( Range of 2250 Oe to 3250 Oe )

Input Voltage

+12 VDC ±5%

Current Draw

Idle: 300 mA

 

Max: 3.0 A (during HiCo encode sequence) and 1 A draw from an

 

Auxiliary Serial Port Device.

MTBF

Electronics: 125, 000 hours

 

Magnetic Read Head: 1 million passes (500,000 insertion cycles)

 

Smartcard contacts: 1 million transactions

Card Speed

7-11 ips

Interface

RS-232, USB

 

MECHANICAL

Dimensions

 

Length

8.440” (includes Mounting Flange) (211.008 mm)

Width

4.470” (111.754 mm)

Height

3.85” (includes Mounting Flange) (97.79 mm)

Weight

2.0 lb (0.9072 Kg)

 

 

 

ENVIRONMENTAL

Temperature

41 oF to 113 oF (5 oC to 45 oC)

Operating

Storage

-40 oF to 158 oF (-40 oC to 70 oC)

Humidity

 

Operating

5% to 95%

Storage

5% to 95% noncondensing

Altitude

 

Operating

0-10,000 ft. (0-3,048 m.)

Storage

0-10,000 ft. (0-3,048 m.)

10

Image 18
Contents Manual Part Number August Registered to ISORevisions Software License Agreement TERMS, Conditions and RestrictionsFCC Warning Statement FCC Compliance Statement Table of Contents Operation and Maintenance Vii IntelliStripe Configurations FeaturesStandards Software AccessoriesApplicable Documents MagTek DocumentsLead-in Roller System Card-Landed Mechanical Switch SensorMotorized Card Transport Front Opto-SensorCard Entry/Orientation Spring-Loaded Card Registration GuidesAbility To Transport 0.010 to 0.035 Cards Magstripe Read/EncodeSmartCard Packing/EnclosureSmall Footprint Electronics and PCBs USB Port Power InputHost Serial Port Auxiliary Serial PortOpto-Sensor Inputs ISO-8 Smartcard Connector with Landing SwitchMicrocontroller LED Indicator Rotary Pulse GeneratorExternal Auto-Ranging Power Pack FirmwareSpecifications SpecificationsMounting Dimensions for Mounting Holes for 3-Screw Set and Foot Pads Rear Panel and Cable ConnectionsRear Panel and Cover Cable Connections RS-232 Cable Connections USB Cable Connections USB Signal Rear Panel Cover Replaced RS-232 Connection Rear Panel Cover Replaced USB Connection IntelliStripe Operation Preventive MaintenanceCorrective Maintenance Ejector Rod for Card JamsEjector Rod Removal from Storage Appendix A. Dimensions for Mounting Figure A-1. Mounting Dimensions Figure A-2. Mounting Dimensions Figure A-3. MagTek Mounting Plate, I380 Figure A-4. MagTek Mounting Plate, I380 Appendix A. Dimensions for Mounting