Nokia CC100 manual New System Firmware and Hcna Driver Files

Page 30

CC100 Master Bridge User’s Guide

Open the ‘EP Management’ window, click on the ‘Refresh’ button first to scan all connected EPs,

In the example, the onboard Master (denoted ‘Local’) device driver version is 2.7.5-3’. The two 3110 EP’s device driver version is 2.7.5-3’,

New System Firmware and HCNA Driver Files

In this example, preparing the following binary files to upgrade the CC100 and the seven connected EPs,

CC100_Sysfw_V3.35.bin Æ CC100 system firmware version ‘3.35

CC100_Driver_V2.7.8-4.binÆ HCNA device driver version 2.7.8-4’, include Master(Local) driver version 2.7.8-4’ , and 3110 Smart EP(as CC101) driver version 2.7.8-4

System Firmware

Upload the New System Firmware

Start from the ‘Upload Firmware’ window and click on ‘Upload’ button,

27

Image 30
Contents User Guide Vcci & CE Table of Contents Features GlossaryPacking List ConnectorsLED Indicators Rear PanelConnecting the Cables Detailed cabling of CC100Verification Different Cabling of CC100Installing the CC100 with an amplifier Configuration Methods Use Web BrowserSystem Setup TCP/IP Properties System Assets InformationEP User Management EP Management Architecture Firmware/Driver FilesMAC Properties Profile Stored the Settings Master HomePNA Properties HpnaCC100 Master Bridge User’s Guide Privacy Mode/Key Summary Profile Status for Master and EP EP HomePNA Properties HpnaMaster/Smart EP Ethernet Properties Ether EP Downstream Igmp v2 Snooping Setup CC100 Master Bridge User’s Guide Delete the Obsolete EP Profile DiagnosisPhysical Connection between Master and EP Administration Administrator Allowed SourceCC100Master Bridge User’s Guide Telnet/Http/SNMP Setup Alert Critical Error Info System LogSystem Time Static MACBackup/Restore Configuration Reboot SystemDefault Setting Upload FirmwareNew System Firmware and Hcna Driver Files System FirmwareCC100Master Bridge User’s Guide CC100 Master Bridge User’s Guide CC100Master Bridge User’s Guide Check the New System Firmware in ‘Upload Area’ Activate the New System Firmware Hcna Driver CC100Master Bridge User’s Guide Also shown on ‘EP Management’ window ‘Upload Area’ Master/EP runs the New Hcna Driver System Firmware and Hcna Driver Version after Upgrade Use Telnet Command Sets for Telnet Console DescriptionEphpnareboot DconfigDefault DiagAllow/deny Reboot HpnarebootIpconfig ServiceCC100 Master Bridge User’s Guide Snmptrapserver SnmptrapsetupSwconfig SntpTime SwtagvlanTftp UpepUse Snmp CC100 Master Bridge User’s Guide 802.1p QoSPriority in Upstream and Downstream TCP/UDP Port NumberSpecifications A N M I S S I O N S P E E D a N D R a N G E R M I N a L D E V I C E S E N D P O I N TLegal & Regulatory Information GNU General Public License Product Warranty Technical Support