2.2 Using the WiSER2400 in a Point-to-multiple point Link

2.2.1Using the WiSER2400 in a point-to-multiple

point link

Scheme 3

See Figure 7 (overleaf)

Connect the PC to an 802.11b/g access point, or use a PC with a built-in 802.11b/g wireless LAN card.

Configure each WiSER2400 to match its serial parameters (baud rate, parity bit, … etc.) with that of the serial device it is to be attached to. Configuration can be done by temporarily connecting the WiSER2400, by a serial cable or wirelessly, to a PC running the WiSER2400 administration software.

Configure each WiSER2400 to match up its UDP/IP settings (listening port, destination IP address, … etc.) with that on the PC side for a UDP/IP connection. Configure the PC side to operate in UDP broadcast mode. Enable each WiSER2400 to receive UDP broadcasts.

Configure the WiSER2400s to operate in the proper wireless network type: Infrastructure mode for linking to an access point, or Ad-hoc mode for linking with a PC with a built-in wireless LAN card.

Attach the WiSER2400s to the serial devices.

Establish the wireless link between the PC and the WiSER2400s. The system is now ready for running the application software on the PC to control the serial devices through the wireless link.

If the application software on the PC can only communicate through a serial COM port interface and does not support the standard TCP/UDP/IP protocols through the network interface, the COM port re-directing software program, VirCOM, will be needed to bridge the application software to the TCP/UDP/IP network port.

Please refer to Section 3 of this manual as well as the VirCOM Technical Manual for details on configuring the WiSER2400 and the Virtual COM port re-directing software.

WiSER 2400 Technical Manual

Version 2.16

Copyright  2001-2005, OTC Wireless, Inc. All Rights Reserved

Page 14 of 32

Image 14
Contents Technical Manual Technical Manual Table of Contents Introduction Key Features Specifications Input PowerSerial Connections PowerStandard Hardware Selecting the Serial Mode for WiSER2400.Plus Status LEDsGround Installation System RequirementsUsing the WiSER2400 in a Point-to-point Link Using the WiSER2400 in a point-to-point link SchemePage Using the WiSER2400 in a point-to-point link Scheme Page Using the WiSER2400 in a Point-to-multiple point Link Using the WiSER2400 in a point-to-multiple Point linkPage Using the WiSER2400 in a point-to-multiple Point link Page Overview TabsDefaults Baud Rate 9600 / Data bits 8 / Parity none Password Protection WiSER2400 Password Utility panelWiSER2400 administration software Link Status panel Link StatusConfiguration Default value 9600 bps Serial PortSerial-IP-Proxy UDPWireless Port SsidPeer Host WEP Keys Creation EncryptionEncryption Wlan Statistics Statistics1 RS232 Statistics Admin Default password none leave blankTroubleshooting AppendixLimited Warranty Recovering from the Data Only ModeRegulatory Compliance FCC ID MKZ0207232XG