OTC Wireless WiSER2400.IP, WiSER2400.Plus Using the WiSER2400 in a point-to-multiple Point link

Page 16

2.2.2Using the WiSER2400 in a point-to-multiple

point link

Scheme 4

See Figure 8 (overleaf)

Configure each WiSER2400 on the device side to match its serial parameters (baud rate, parity bit, … etc.) with that of the serial device it is to be attached to. Configuration can be done by temporarily connecting the WiSER2400, by a serial cable or wirelessly, to a PC running the WiSER2400 administration software. Similarly, configure the serial parameters of the WiSER2400 on the PC side so that it can communicate with the PC.

Configure the WiSER2400s on either side of the link to match up their UDP/IP settings (listening port, destination IP address, … etc.) for a UDP/IP connection. Enable the WiSER2400 on the PC side to send UDP broadcasts. Enable each WiSER2400 on the device side to receive UDP broadcasts.

Configure the WiSER2400s on both sides to operate in the Ad-hoc mode.

Attach the WiSER2400s to the serial device and the PC. Establish the wireless link between the PC and the WiSER2400. The system is now ready for running the application software on the PC to control the serial devices through the wireless link.

Please refer to Section 3 of this manual for details on configuring the

WiSER2400.

WiSER 2400 Technical Manual

Version 2.16

Copyright  2001-2005, OTC Wireless, Inc. All Rights Reserved

Page 16 of 32

Image 16
Contents Technical Manual Technical Manual Table of Contents Introduction Key Features Specifications Input PowerStandard Hardware PowerSerial Connections Selecting the Serial Mode for WiSER2400.Plus Status LEDsGround Installation System RequirementsUsing the WiSER2400 in a Point-to-point Link Using the WiSER2400 in a point-to-point link SchemePage Using the WiSER2400 in a point-to-point link Scheme Page Using the WiSER2400 in a Point-to-multiple point Link Using the WiSER2400 in a point-to-multiple Point linkPage Using the WiSER2400 in a point-to-multiple Point link Page Overview TabsDefaults Baud Rate 9600 / Data bits 8 / Parity none Password Protection WiSER2400 Password Utility panelWiSER2400 administration software Link Status panel Link StatusConfiguration Default value 9600 bps Serial PortSerial-IP-Proxy UDPWireless Port SsidPeer Host Encryption EncryptionWEP Keys Creation 1 RS232 Statistics StatisticsWlan Statistics Admin Default password none leave blankTroubleshooting AppendixLimited Warranty Recovering from the Data Only ModeRegulatory Compliance FCC ID MKZ0207232XG