3.4.1 Serial Port

(Refer to Fig. 14 on previous page).

Serial Parameter

Baud rate: for setting the baud rate of the WiSER2400’s serial port. Supported values: 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, and 115200 bps.

Default value: 9600 bps

Parity Bit: for setting the error-checking bit. Supported values: “None”, “Even”, and “Odd”

Data Bit: for setting the number of bits in the data section. Supported valued: 7 and 8.

Stop Bit:

supported value: 1.

Flow Control: for setting local flow control option for the serial connection. Supported modes: None, XON/XOFF and Hardware flow control.

Serial Interface

The WiSER2400.IP supports RS-232 serial interface.

The WiSER2400.Plus supports RS-232/485/422 serial interfaces.

Data Packetizing

Start Frame Byte(s): This value specifies a special character or characters that signals the start of a data-string. Range from 0x00 to 0x1F and options of “None” and “Other”. If “none” is selected, there would be no Start Frame Byte. If “Other” is selected, the user can configure a Start Frame Byte of up to six bytes.

Default value: none

End Frame Byte: This value specifies the character that signals the end of a data-string, and the data would be sent to the destination unit right after the radio receives the designated character. Range 0x00 to 0x1F.

Default value: 0x0D = Carriage Return

If the user specifies ‘None’ (or leaves the field blank), this will signify that there is no End Frame Byte and data will be sent immediately once the WiSER2400 receives the next Start Frame Byte.

Max Bytes/Pkt: This value specifies the maximum number of bytes the WiSER2400 will hold before they are sent off.

Range: 1 to 200 bytes.

Default value: 200 bytes

Serial Mode

Data Only Mode: When this mode is activated, the WiSER2400 serial port would accept only communication data traffic and ignore the configuration command. This mode will stop the communication between the administrative software and the WiSER2400. To re- gain the access to the WiSER2400 for administration, refer to the Troubleshooting Section for recovery instructions.

Default value: Data Only Mode

Data and Command Mode:

In this mode, the WiSER2400 serial port accepts both communication data traffic and the administration commands.

WiSER 2400 Technical Manual

Version 2.16

Copyright  2001-2005, OTC Wireless, Inc. All Rights Reserved

Page 23 of 32

Image 23
Contents Technical Manual Technical Manual Table of Contents Introduction Input Power Key Features SpecificationsSerial Connections PowerStandard Hardware Status LEDs Selecting the Serial Mode for WiSER2400.PlusGround System Requirements InstallationUsing the WiSER2400 in a point-to-point link Scheme Using the WiSER2400 in a Point-to-point LinkPage Using the WiSER2400 in a point-to-point link Scheme Page Using the WiSER2400 in a point-to-multiple Point link Using the WiSER2400 in a Point-to-multiple point LinkPage Using the WiSER2400 in a point-to-multiple Point link Page Tabs OverviewDefaults Baud Rate 9600 / Data bits 8 / Parity none WiSER2400 Password Utility panel Password ProtectionLink Status WiSER2400 administration software Link Status panelConfiguration Serial Port Default value 9600 bpsUDP Serial-IP-ProxySsid Wireless PortPeer Host WEP Keys Creation EncryptionEncryption Wlan Statistics Statistics1 RS232 Statistics Default password none leave blank AdminAppendix TroubleshootingRecovering from the Data Only Mode Limited WarrantyFCC ID MKZ0207232XG Regulatory Compliance