INTRODUCTION

The WiSER2400.IP and the WiSER2400.Plus are IEEE 802.11b compliant devices with built-in serial interfaces. They are designed to allow non- wirelessly enabled serial devices to be connected and fully integrated into an 802.11 Network.

The WiSER2400 receives data from equipment with serial ports; converts the serial data into 802.11 compliant TCP or UDP data packets and transmits these packets wirelessly. Conversely, the WiSER can receive wireless packets, which it unpacks and delivers byte-by-byte to the destination equipment/device through a serial port.

The WiSER2400 requires no device driver and is operating system independent. They can be used with almost any type of equipment that uses a serial port, including (but not limited to) cash registers, electronic whiteboards

and navigational instruments. Administration of the WiSER2400 is doneFig. 1 WiSER2400.IP through a Windows based administrative software program. The

administration software can be used to configure the unit’s operating parameters, administrative and local network settings. It can also be used to monitor the unit’s communication link conditions.

The WiSER2400.IP comes with an RS-232 interface and a built-in 2dBi antenna. It comes supplied with a 5V DC power adapter.

The WiSER2400.Plus provides the same functionalities as the WiSER2400.IP. It has an RS-232 DB-9 connector as well as a mini- Phoenix connector for RS-485/422 interfaces. It accepts 5V DC to 32V DC power supply that has to be provided for separately by the user. Input power connection is made through the mini-Phoenix connector. It also comes with a DIN rail mounting clip and plate assembly.

Fig. 2 WiSER2400.Plus

Note: Throughout this manual, the term WiSER2400 is used to refer to both the WiSER2400.IP and the WiSER2400.Plus

WiSER 2400 Technical Manual

Version 2.16

Copyright  2001-2005, OTC Wireless, Inc. All Rights Reserved

Page 4 of 32

Image 4
Contents Technical Manual Technical Manual Table of Contents Introduction Key Features Specifications Input PowerStandard Hardware PowerSerial Connections Selecting the Serial Mode for WiSER2400.Plus Status LEDsGround Installation System RequirementsUsing the WiSER2400 in a Point-to-point Link Using the WiSER2400 in a point-to-point link SchemePage Using the WiSER2400 in a point-to-point link Scheme Page Using the WiSER2400 in a Point-to-multiple point Link Using the WiSER2400 in a point-to-multiple Point linkPage Using the WiSER2400 in a point-to-multiple Point link Page Overview TabsDefaults Baud Rate 9600 / Data bits 8 / Parity none Password Protection WiSER2400 Password Utility panelWiSER2400 administration software Link Status panel Link StatusConfiguration Default value 9600 bps Serial PortSerial-IP-Proxy UDPWireless Port SsidPeer Host Encryption EncryptionWEP Keys Creation 1 RS232 Statistics StatisticsWlan Statistics Admin Default password none leave blankTroubleshooting AppendixLimited Warranty Recovering from the Data Only ModeRegulatory Compliance FCC ID MKZ0207232XG