Sharp JW-21MN manual 16-10

Page 105

(3 / 5)

Address(8)

Set contents

Setting method (value, example)

 

 

 

 

005000

Number of sending bytes of master station relay

(Decimal, word)

 

005001

link area

When 8 bytes, set to 00008(D)

 

005002

Number of sending bytes of slave station 01(8)

(Decimal, word)

 

005003

relay link area

 

 

 

16

Address(8)

Set contents

 

 

005004 to 005005

Number of sending bytes of slave station 02(8)

relay link area (same as 005002 to 005003).

005006 to 005007

03(8) (same as 005002 to 005003)

005010 to 005011

04(8) (same as 005002 to 005003)

005012 to 005013

05(8) (same as 005002 to 005003)

005014 to 005015

06(8) (same as 005002 to 005003)

005016 to 005017

07(8) (same as 005002 to 005003)

005020 to 005021

10(8) (same as 005002 to 005003)

005022 to 005023

11(8) (same as 005002 to 005003)

 

 

005024 to 005025

12(8) (same as 005002 to 005003)

 

 

005026 to 005027

13(8) (same as 005002 to 005003)

 

 

005030 to 005031

14(8) (same as 005002 to 005003)

005032 to 005033

15(8) (same as 005002 to 005003)

005034 to 005035

16(8) (same as 005002 to 005003)

 

 

005036 to 005037

17(8) (same as 005002 to 005003)

 

 

005040 to 005041

20(8) (same as 005002 to 005003)

 

 

005042 to 005043

21(8) (same as 005002 to 005003)

 

 

005044 to 005045

22(8) (same as 005002 to 005003)

 

 

005046 to 005047

23(8) (same as 005002 to 005003)

 

 

005050 to 005051

24(8) (same as 005002 to 005003)

 

 

005052 to 005053

25(8) (same as 005002 to 005003)

 

 

005054 to 005055

26(8) (same as 005002 to 005003)

 

 

005056 to 005057

27(8) (same as 005002 to 005003)

 

 

005060 to 005061

30(8) (same as 005002 to 005003)

005062 to 005063

31(8) (same as 005002 to 005003)

 

 

005064 to 005065

32(8) (same as 005002 to 005003)

 

 

005066 to 005067

33(8) (same as 005002 to 005003)

 

 

005070 to 005071

34(8) (same as 005002 to 005003)

005072 to 005073

35(8) (same as 005002 to 005003)

005074 to 005075

36(8) (same as 005002 to 005003)

 

 

005076 to 005077

37(8) (same as 005002 to 005003)

 

 

Address(8)

Set contents

 

 

005100 to 005101

Number of sending bytes of slave station 40(8)

relay link area (same as 005002 to 005003).

 

005102 to 005103

41(8) (same as 005002 to 005003)

 

 

005104 to 005105

42(8) (same as 005002 to 005003)

005106 to 005107

43(8) (same as 005002 to 005003)

 

 

005110 to 005111

44(8) (same as 005002 to 005003)

005112 to 005113

45(8) (same as 005002 to 005003)

005114 to 005115

46(8) (same as 005002 to 005003)

005116 to 005117

47(8) (same as 005002 to 005003)

005120 to 005121

50(8) (same as 005002 to 005003)

 

 

005122 to 005123

51(8) (same as 005002 to 005003)

005124 to 005125

52(8) (same as 005002 to 005003)

005126 to 005127

53(8) (same as 005002 to 005003)

005130 to 005131

54(8) (same as 005002 to 005003)

 

 

005132 to 005133

55(8) (same as 005002 to 005003)

 

 

005134 to 005135

56(8) (same as 005002 to 005003)

 

 

005136 to 005137

57(8) (same as 005002 to 005003)

 

 

005140 to 005141

60(8) (same as 005002 to 005003)

 

 

005142 to 005143

61(8) (same as 005002 to 005003)

 

 

005144 to 005145

62(8) (same as 005002 to 005003)

 

 

005146 to 005147

63(8) (same as 005002 to 005003)

 

 

005150 to 005151

64(8) (same as 005002 to 005003)

 

 

005152 to 005153

65(8) (same as 005002 to 005003)

 

 

005154 to 005155

66(8) (same as 005002 to 005003)

005156 to 005157

67(8) (same as 005002 to 005003)

 

 

005160 to 005161

70(8) (same as 005002 to 005003)

 

 

005162 to 005163

71(8) (same as 005002 to 005003)

 

 

005164 to 005165

72(8) (same as 005002 to 005003)

 

 

005166 to 005167

73(8) (same as 005002 to 005003)

005170 to 005171

74(8) (same as 005002 to 005003)

005172 to 005173

75(8) (same as 005002 to 005003)

 

 

005174 to 005175

76(8) (same as 005002 to 005003)

005176 to 005177

77(8) (same as 005002 to 005003)

 

 

- Initial value of the address 005000 to 005177(8) are all 00(H).

16-10

Image 105
Contents JW-21MN JW-21MN Safety Precautions InstallationWiring Compel Use Maintenance ProhibitME-NET Module JW-21MN Table of contents Setting of Switches and Parameter 11-1 to Errors and Countermeasures 12-1 toDescription for Computer Link Operation 10-1 to Support Tools 14-1 to Specifications 15-1 to 13-1Appendix 16-1 to Features and Functions Data link functionComputer link function Wiring InstallationConnector Treatment MaintenanceStatic electricity Allocation of relay numberJW20H JW-21MN JW-21MN JW30H System ConfigurationFront view Name and Function of Each PartInstallation Installation procedureRemarks Name Model Maker Processing of CablesProcessing cable end Fine adjustment of blade cutting depth Cutting of coating, external conductor, and insulatorRemoval of coating, external conductor, and insulator Processing of cable end Display of blade settingConnector ME-GP-01 Processing procedure Insert a sleeve Connector crimping procedureRequired tools Hand-held crimping tool Crimping contactFixing the connector Insulation testConductivity test Wiring Method Cable trunk and branch linesRelaying of trunk cables Cable wiring procedure in control panel Page Branch connector Waterproof and insulation processing of connectorsStraight connector RemarksCheck after wiring Wiring of cables at outside control panelsStation number of the additional station Branching methodReason Memory Address on the ME-NET Memory address for data linksMemory address map against JW20/JW20H JW30H address ME-NET address Memory address map against JW30HJW20/20H ME-NET address Capacity Memory addresses for computer linksJW30H address ME-NET address Capacity Remarks Communication method Description for Data Link OperationData link Standard function Relay linkSetting item Set location Data link Save memory functionRegister link Required transmission time Required transmission time and communication delay timeCommunication delay time An example of synchronized transfer by OUT instruction Data transmission between master PC and slave PCMultiple installation of the JW-21MN Expansion of networkCase of mounting 4 sets of JW-21MN Hierarchical link Optional commands Basic commandsDescription for Computer Link Operation Computer link function10-2 Basic commandsOptional commands 10-3Communication format, basic pattern Read free memory size Write mode assignment None Communication formatMonitor TMR, CNT, and MD 10-4Reading PC mode Setting PC mode10-5 Reading system memory Writing system memory10-6 Write mode assignment 1 or Communication format Setting dateReading date 10-7Setting time Reading time10-8 Correct clock time Monitor step status JW20/JW20H only10-9 Read the optional parameters Write mode assignmentSet the optional parameters 10-10Read the special I/O parameters Set the special I/O parameters10-11 Release the secret function, register password JW30H only Set the secret function JW30H only10-12 10-13 Check the secret function JW30H only10-14 Response on errorSetting of Switches and Parameter Operation procedure11-1 Mode switch Mode Switch setting of master station and slave stationModule No. switch Unit no 11-2Termination resistance switch LT Station number switch STA no11-3 Reference Need for the termination resistance11-4 Shield ground switch LGSetting contents of master station parameters Value H 11-6Parameter for setting in slave station Parameter for setting in master stationCommunication area map 11-711-8 11-9 + hExample for setting 11-10Maser station Slave station Standard Save memory 11-11 When master station PC is JW20/JW20H11-12 When master station PC is JW30H11-13 Setting procedure11-14 Example Stop operation of data link HEX hexadecimal, byteStop operation of data link HEX hexadecimal, byte Data link function setting HEX hexadecimal, byte Set number of connecting stations DCM decimal, byte11-15 Set top address of register link area on the master station 11-16Set in parameter addresses 005000 to 11-1711-18 Set connection status of slave station Bit pattern, byte 11-1911-20 PC operation 11-21Setting item Contents11-22 When PC is JW20/JW20H Setting range of flag areaWhen PC is JW30H 11-2311-24 11-25 Turn on the power of slave station PC Connect support tools11-26 11-27 11-28 Indication lamps Errors and Countermeasures12-1 Details MeasureRemark Flag12-3 Case of a master stationCommunication monitor flag Operation condition monitor flag12-4 Case of slave station 01 to12-5 Monitor operation condition by each station PC12-6 Storage of error codeSystem memory #160 to 167 self diagnosis error code System memory #170 to 177 option module error codeSystem memory #150 monitor error switch number 12-712-8 Error history13-1 Replacement of the JW-21MNSupport Tools Record and load by ladder software JW-92SP, JW-50SP Record14-1 14-2 LoadLoad to the personal computer Stop operation of the JW-21MNGeneral specifications SpecificationsCommunication specifications SpecificationStandard function Specifications Data link specificationsSave memory function Specifications 15-2Computer link specifications Outside dimensional drawings15-3 Maintenance and check Appendix16-1 Recovery method at communication errors Check flow chart16-2 16-3 Check cable/connectorCause Countermeasure 16-4007764 to 16-5Check items of cables and connectors Switches required check in the JW-21MN16-6 Other casesIdentify the error station Check the errors timingWhen identification of the cause is difficult 16-7Table of parameter memory 16-8Master station 16-9 Set contents Setting method value, example16-10 16-11 Slave station 01 to 16-1216-13 Special functions unique to the JW-21MNRemote programming and remote monitor Support tool Opposite module Connection moduleFunction Standard network connection 16-14Expansion network connection Operation example16-15 Network settingParameter setting by remote function When used with a computer link16-16 Alphabetical Index Operation procedure Waterproof and insulation processing of connectors