Sharp JW-21MN manual Errors and Countermeasures, Indication lamps, 12-1, Details Measure

Page 82

Chapter 12: Errors and Countermeasures

The operating condition of the JW-21MN can be monitored using its indication lamps, flags, and the system memory of a PC.

12-1 Indication lamps

 

 

 

 

 

 

 

 

 

 

ME-NET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMM

RD

 

LT

COM.E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED

 

 

 

 

 

 

 

 

Details

Measure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

name

 

 

 

 

 

 

 

 

 

 

 

 

 

SD

 

 

CD

 

T

UNT.E

 

 

CM

 

Lights during data link operation

 

 

 

 

 

 

80

40

20

10

8

4

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SD

 

Lights while sending data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

Lights while receiving data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CD

 

Lights when detecting carrier

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT

 

Lights when turning ÒONÓ the termination resistance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

Lights during testing (TEST)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Check disconnection of the communication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lights at a communication error

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM.E

- Check the set contents of switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(COM. E)

 

 

 

 

- Cheek the set contents of parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Check the power voltage of PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNT.E

Lights at time up of the watchdog timer

Replace the JW-21MN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED "1" to "80" indicate error codes when an error occurs. Error codes, their

 

 

 

 

 

 

 

 

 

 

 

 

causes, and measures are as shown in the table below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED name

 

 

Error

 

Cause

 

 

 

Measure

 

 

 

 

 

 

 

 

 

 

80

40

20

10

 

8

4

 

2

1

code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(DEC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

ROM error, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

RAM error, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03

2 port RAM error against PC, upper CPU

Replace the JW-21MN

 

 

 

 

 

 

 

 

04

2 port RAM error against communication CPU, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

ROM error, communication CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Check the communication

 

 

 

 

 

 

12

RAM error, communication CPU

 

 

 

 

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Check for doubled allocation

 

 

 

 

 

18

Communication LSI error, communication CPU

 

 

 

 

 

 

of station number

 

 

 

 

 

 

 

 

 

 

 

1F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No response, communication CPU

 

- Replace the JW-21MN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

More than one token detected

Check the parameter setting

 

 

 

 

 

 

21

Doubled address detected

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Fault of sending section

Replace the JW-21MN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

Token does not return within the rated interval

Check the communication cable

 

 

 

 

2A

Over flow of receiving buffer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2B

Flame length error

Check the communication cable

 

 

 

 

30

EEPROM error

 

 

 

Replace the JW-21MN

 

 

 

 

 

 

 

 

*60

Switch setting error

Check the switch setting

 

 

 

 

 

 

 

 

*6E

BCC error

 

 

 

Check the parameter setting

 

 

 

 

 

 

6F

Parameter setting error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*C1

Communication error

Check the communication cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- After converting into octal, the lower two digits

 

 

 

 

 

 

 

 

 

to

 

 

 

 

 

to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and slave module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

represent the slave station number of the current

 

 

 

 

 

 

 

 

 

 

 

● ● ● ● ● ● ● ●

* FF

 

 

 

 

 

 

 

 

 

 

 

error. (Ex. C1(H) = 301(8) = slave station 01)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: ON, ○ : OFF

* Error code 60(H), 6E(H), C1 to FF(H) are special error codes unique to the JW-21MN. Other codes are error codes specified by the ME-NET.

Prior to displaying the error code C1 to FF(H), the setting of the parameter addresses 007750 to 007757(8) is required. (See page 16-12.)

12

12-1

Image 82
Contents JW-21MN JW-21MN Installation Safety PrecautionsWiring Compel Maintenance Prohibit UseME-NET Module JW-21MN Table of contents Errors and Countermeasures 12-1 to Setting of Switches and Parameter 11-1 toDescription for Computer Link Operation 10-1 to 13-1 Support Tools 14-1 to Specifications 15-1 toAppendix 16-1 to Data link function Features and FunctionsComputer link function Installation WiringConnector Static electricity MaintenanceTreatment Allocation of relay numberSystem Configuration JW20H JW-21MN JW-21MN JW30HName and Function of Each Part Front viewInstallation procedure InstallationRemarks Processing of Cables Name Model MakerProcessing cable end Cutting of coating, external conductor, and insulator Fine adjustment of blade cutting depthRemoval of coating, external conductor, and insulator Display of blade setting Processing of cable endRequired tools Hand-held crimping tool Connector crimping procedureConnector ME-GP-01 Processing procedure Insert a sleeve Crimping contactInsulation test Fixing the connectorConductivity test Cable trunk and branch lines Wiring MethodRelaying of trunk cables Cable wiring procedure in control panel Page Straight connector Waterproof and insulation processing of connectorsBranch connector RemarksWiring of cables at outside control panels Check after wiringBranching method Station number of the additional stationReason Memory address for data links Memory Address on the ME-NETMemory address map against JW20/JW20H Memory address map against JW30H JW30H address ME-NET addressMemory addresses for computer links JW20/20H ME-NET address CapacityJW30H address ME-NET address Capacity Remarks Data link Standard function Description for Data Link OperationCommunication method Relay linkData link Save memory function Setting item Set locationRegister link Required transmission time and communication delay time Required transmission timeCommunication delay time Data transmission between master PC and slave PC An example of synchronized transfer by OUT instructionExpansion of network Multiple installation of the JW-21MNCase of mounting 4 sets of JW-21MN Hierarchical link Description for Computer Link Operation Basic commandsOptional commands Computer link functionBasic commands 10-210-3 Optional commandsCommunication format, basic pattern Monitor TMR, CNT, and MD Write mode assignment None Communication formatRead free memory size 10-4Setting PC mode Reading PC mode10-5 Writing system memory Reading system memory10-6 Reading date Setting dateWrite mode assignment 1 or Communication format 10-7Reading time Setting time10-8 Monitor step status JW20/JW20H only Correct clock time10-9 Set the optional parameters Write mode assignmentRead the optional parameters 10-10Set the special I/O parameters Read the special I/O parameters10-11 Set the secret function JW30H only Release the secret function, register password JW30H only10-12 Check the secret function JW30H only 10-13Response on error 10-14Operation procedure Setting of Switches and Parameter11-1 Module No. switch Unit no Switch setting of master station and slave stationMode switch Mode 11-211-3 Station number switch STA noTermination resistance switch LT Reference Need for the termination resistanceShield ground switch LG 11-4Setting contents of master station parameters 11-6 Value HCommunication area map Parameter for setting in master stationParameter for setting in slave station 11-711-8 + h 11-911-10 Example for settingMaser station Slave station Standard Save memory When master station PC is JW20/JW20H 11-11When master station PC is JW30H 11-12Setting procedure 11-13Example Stop operation of data link HEX hexadecimal, byte 11-14Stop operation of data link HEX hexadecimal, byte Set number of connecting stations DCM decimal, byte Data link function setting HEX hexadecimal, byte11-15 11-16 Set top address of register link area on the master station11-17 Set in parameter addresses 005000 to11-18 11-19 Set connection status of slave station Bit pattern, byte11-20 11-21 PC operationContents Setting item11-22 When PC is JW30H Setting range of flag areaWhen PC is JW20/JW20H 11-2311-24 Turn on the power of slave station PC Connect support tools 11-25 11-26 11-27 11-28 12-1 Errors and CountermeasuresIndication lamps Details MeasureFlag RemarkCommunication monitor flag Case of a master station12-3 Operation condition monitor flagCase of slave station 01 to 12-4Monitor operation condition by each station PC 12-5Storage of error code 12-6System memory #150 monitor error switch number System memory #170 to 177 option module error codeSystem memory #160 to 167 self diagnosis error code 12-7Error history 12-8Replacement of the JW-21MN 13-1Record and load by ladder software JW-92SP, JW-50SP Record Support Tools14-1 Load to the personal computer Load14-2 Stop operation of the JW-21MNCommunication specifications SpecificationsGeneral specifications SpecificationSave memory function Specifications Data link specificationsStandard function Specifications 15-2Outside dimensional drawings Computer link specifications15-3 Appendix Maintenance and check16-1 Check flow chart Recovery method at communication errors16-2 Check cable/connector 16-316-4 Cause Countermeasure16-5 007764 to16-6 Switches required check in the JW-21MNCheck items of cables and connectors Other casesWhen identification of the cause is difficult Check the errors timingIdentify the error station 16-716-8 Table of parameter memoryMaster station Set contents Setting method value, example 16-916-10 16-11 16-12 Slave station 01 toRemote programming and remote monitor Special functions unique to the JW-21MN16-13 Support tool Opposite module Connection moduleExpansion network connection 16-14Function Standard network connection Operation exampleNetwork setting 16-15When used with a computer link Parameter setting by remote function16-16 Alphabetical Index Operation procedure Waterproof and insulation processing of connectors