Sharp JW-21MN Support Tools, Record and load by ladder software JW-92SP, JW-50SP Record, 14-1

Page 91
JW-22KC/24KC
Connection cable
JW-50SP

Chapter 14: Support Tools

The following support tools are available to record (store), and load the contents of the parameter memory.

(Make sure to save the set parameters onto a floppy diskette.)

Model name

Applicable floppy diskettes

Ladder software (JW-92SP, JW-50SP)

3.5-inch 2DD/2HD, 5-inch 2DD/2HD

 

 

Multipurpose programmer (JW-50PG)

3.5-inch 2DD

 

 

Ladder processor II (Z-100LP2S)

3.5-inch 2DD

 

 

Record and load by ladder software (JW-92SP, JW-50SP) <Record>

(1)Stop operation of the JW-21MN Select "PC TRANS."

Select "Read."

Select "DL. M. stn. PARAM." or "DL. S. stn.

PARAM."

When the connected JW-21MN is master station, select "DL. M. stn. PARAM." When the connected JW-21MN is slave station, select "DL. S. stn. PARAM."

After selecting "PC stop," press the "Enter" key.

JW-21MN

(2)Record onto the personal computer

After stopping operation, record the parameters of the JW-21MN onto the memory of the personal computer. Select "Read out PARAM" and press the "Enter" key.

Start reading to memory of the personal computer.

(3)Start operation of the JW-21MN

After recording the parameters onto the personal computer, start operation of the JW-21MN. Select "Start operation."

Start operation of the JW-21MN

(4)Record onto a floppy diskette

Write (record) the memory contents of the personal computer onto a floppy diskette.

Select "FD TRANS."

Select "Save."

Select "DL. M. PARAM." or "DL. S. PARAM."

When the memory contents of the personal computer are for a master station, select "DL. M. PARAM." When the memory contents of the personal computer are for a slave station, select "DL. S. PARAM."

Input a file name to record.

14

Input comments.

Press the "Enter" key.

Start recording onto the floppy diskette.

14-1

Image 91
Contents JW-21MN JW-21MN Installation Safety PrecautionsWiring Compel Use Maintenance ProhibitME-NET Module JW-21MN Table of contents Errors and Countermeasures 12-1 to Setting of Switches and Parameter 11-1 toDescription for Computer Link Operation 10-1 to 13-1 Support Tools 14-1 to Specifications 15-1 toAppendix 16-1 to Data link function Features and FunctionsComputer link function Wiring InstallationConnector Allocation of relay number MaintenanceTreatment Static electricityJW20H JW-21MN JW-21MN JW30H System ConfigurationFront view Name and Function of Each PartInstallation procedure InstallationRemarks Name Model Maker Processing of CablesProcessing cable end Cutting of coating, external conductor, and insulator Fine adjustment of blade cutting depthRemoval of coating, external conductor, and insulator Processing of cable end Display of blade settingCrimping contact Connector crimping procedureConnector ME-GP-01 Processing procedure Insert a sleeve Required tools Hand-held crimping toolInsulation test Fixing the connectorConductivity test Cable trunk and branch lines Wiring MethodRelaying of trunk cables Cable wiring procedure in control panel Page Remarks Waterproof and insulation processing of connectorsBranch connector Straight connectorCheck after wiring Wiring of cables at outside control panelsStation number of the additional station Branching methodReason Memory address for data links Memory Address on the ME-NETMemory address map against JW20/JW20H JW30H address ME-NET address Memory address map against JW30HJW20/20H ME-NET address Capacity Memory addresses for computer linksJW30H address ME-NET address Capacity Remarks Relay link Description for Data Link OperationCommunication method Data link Standard functionData link Save memory function Setting item Set locationRegister link Required transmission time Required transmission time and communication delay timeCommunication delay time An example of synchronized transfer by OUT instruction Data transmission between master PC and slave PCExpansion of network Multiple installation of the JW-21MNCase of mounting 4 sets of JW-21MN Hierarchical link Computer link function Basic commandsOptional commands Description for Computer Link Operation10-2 Basic commands10-3 Optional commandsCommunication format, basic pattern 10-4 Write mode assignment None Communication formatRead free memory size Monitor TMR, CNT, and MDSetting PC mode Reading PC mode10-5 Writing system memory Reading system memory10-6 10-7 Setting dateWrite mode assignment 1 or Communication format Reading dateReading time Setting time10-8 Monitor step status JW20/JW20H only Correct clock time10-9 10-10 Write mode assignmentRead the optional parameters Set the optional parametersSet the special I/O parameters Read the special I/O parameters10-11 Set the secret function JW30H only Release the secret function, register password JW30H only10-12 10-13 Check the secret function JW30H only10-14 Response on errorOperation procedure Setting of Switches and Parameter11-1 11-2 Switch setting of master station and slave stationMode switch Mode Module No. switch Unit noReference Need for the termination resistance Station number switch STA noTermination resistance switch LT 11-311-4 Shield ground switch LGSetting contents of master station parameters Value H 11-611-7 Parameter for setting in master stationParameter for setting in slave station Communication area map11-8 11-9 + h11-10 Example for settingMaser station Slave station Standard Save memory 11-11 When master station PC is JW20/JW20H11-12 When master station PC is JW30H11-13 Setting procedureExample Stop operation of data link HEX hexadecimal, byte 11-14Stop operation of data link HEX hexadecimal, byte Set number of connecting stations DCM decimal, byte Data link function setting HEX hexadecimal, byte11-15 Set top address of register link area on the master station 11-16Set in parameter addresses 005000 to 11-1711-18 Set connection status of slave station Bit pattern, byte 11-1911-20 PC operation 11-21Contents Setting item11-22 11-23 Setting range of flag areaWhen PC is JW20/JW20H When PC is JW30H11-24 11-25 Turn on the power of slave station PC Connect support tools11-26 11-27 11-28 Details Measure Errors and CountermeasuresIndication lamps 12-1Remark FlagOperation condition monitor flag Case of a master station12-3 Communication monitor flag12-4 Case of slave station 01 to12-5 Monitor operation condition by each station PC12-6 Storage of error code12-7 System memory #170 to 177 option module error codeSystem memory #160 to 167 self diagnosis error code System memory #150 monitor error switch number12-8 Error history13-1 Replacement of the JW-21MNRecord and load by ladder software JW-92SP, JW-50SP Record Support Tools14-1 Stop operation of the JW-21MN Load14-2 Load to the personal computerSpecification SpecificationsGeneral specifications Communication specifications15-2 Data link specificationsStandard function Specifications Save memory function SpecificationsOutside dimensional drawings Computer link specifications15-3 Appendix Maintenance and check16-1 Check flow chart Recovery method at communication errors16-2 16-3 Check cable/connectorCause Countermeasure 16-4007764 to 16-5Other cases Switches required check in the JW-21MNCheck items of cables and connectors 16-616-7 Check the errors timingIdentify the error station When identification of the cause is difficult16-8 Table of parameter memoryMaster station 16-9 Set contents Setting method value, example16-10 16-11 Slave station 01 to 16-12Support tool Opposite module Connection module Special functions unique to the JW-21MN16-13 Remote programming and remote monitorOperation example 16-14Function Standard network connection Expansion network connection16-15 Network settingWhen used with a computer link Parameter setting by remote function16-16 Alphabetical Index Operation procedure Waterproof and insulation processing of connectors