AMX Anterus manual Global Reader Configuration Options

Page 24

Anterus Configuration Manager

Global Reader Configuration Options

The top section of the Global Register page contains ANT-RDR configuration options (FIG. 20):

FIG. 20 Global Register page - Global Reader Configuration Options

These options apply to ALL ANT-RDR Readers in the system. Use the options in this page to set global defaults for all Readers and Tags in the Anterus system.

Settings made to individual Readers via the Reader Configuration Pages (see the Reader

Configuration Pages section on page 24) will override these global settings.

Global Register page - Global Reader Configuration Options

• Reader ID:

Indicates the Device ID for the selected ANT-RDR. In the Global Registery

 

page, the Reader ID is always zero (0), and cannot be changed.

 

 

• Reader Address:

Indicates the AxLink Device Address for the selected ANT-RDR. In the

 

Global Registery page, the Reader ID is always "Global", and cannot be

 

changed.

 

 

• Acquired Threshold (1...255):

The ANT-RDR will notify the Master that a Tag's signal has been acquired

 

when its RSSI signal is above the Acquired Threshold value.

 

• The allowed range is 1 (min.) to 255 (max)

 

• Default = 200

 

 

• Lost Threshold (0...254):

The ANT-RDR will notify the Master that a Tag's signal has been lost when

 

its RSSI signal is below the Lost Threshold value.

 

• The allowed range is 0 (min.) to 254 (max)

 

• Default = 50

 

 

• Sensitivity (1...255)

The Sensitivity setting is used to reduce the message traffic between the

 

ANT-RDR and the Master:

 

The ANT-RDR remembers the last RSSI value sent to the Master for each

 

Tag it has acquired. On the next poll, only Tags whose current RSSI value is

 

outside the range of the last sent RSSI value +/- the Sensitivity value

 

entered here will be sent to the Master.

 

• The allowed range is 1 (min.) to 255 (max)

 

• Default = 30

 

 

Tag-Lost Timeout (30...255

Use this option to specify the period time allowed to continue monitoring

seconds)

Tags whose RFID signal has dropped below the level specified in the Lost

 

Threshold.

 

• If a Tag’s RSSI signal has dropped below the Lost Threshold level, and is

 

re-acquired by the Reader within the time period specified here, it will

 

automatically resume normal functionality.

 

• Conversely, if a Tag’s RSSI signal drops below the Lost Threshold level,

 

and is not re-acquired within the specified time period, the Reader will no

 

longer monitor for that Tag. Therefore, once the timeout period has

 

elapsed, the Tag will not be automatically re-acquired, and must be

 

manually re-entered into the system.

 

• Default = 30 seconds.

 

 

• Status (Online/Offline)

Indicates the current status of the selected ANT-RDR (display-only).

 

 

20

Anterus RFID Solution

Image 24
Contents Anterus AMX Limited Warranty and Disclaimer Table of Contents Anterus Configuration Manager Anterus Rfid Solution OverviewANT-RDR Rfid Reader Anterus Rfid GroupANT-RDR Product Specifications ANT-RDR Mounting/InstallationANT-RDR Specifications Rfid Tags Internal Battery Anterus Rfid TagsANT-TAG Product Specifications ANT-TAG SpecificationsANT-TAG Device/Asset Tag ANT-TAG Mounting/Installation ANT-BDG ID Badge TagANT-TAG Antenna Orientation ANT-BDG Product Specifications ANT-BDG Mounting/InstallationANT-BDG Specifications ANT-BDG Antenna OrientationSignal Strength Behavior of AMX Rfid Tags and Readers Environmental FactorsNon-Ideal Antenna Gain Antenna ElevationAnalysis People and ObjectsMultipath Fading Measured DataSignal Strength Count Behavior ConclusionsConnecting the ANT-RDR To a NetLinx Master Connecting Additional ANT-RDRsWiring Guidelines Power DistributionCalculating AXlink wiring distances Cable Types and Maximum DistancesGauge/resistance factors Solid Copper Wiring Device DIP Switch SettingsWire gauge Wire Resistance/foot Assigning the ANT-RDR Device AddressInstallation Anterus Rfid Solution Anterus Configuration Manager Accessing the Rfid Configuration ManagerOpen the Manage Devices tab FIG Rfid Configuration Manager Main Rfid Configuration Manager page FIGRfid Configuration Manager Global Register Global RegisterGlobal Reader Configuration Options Global Register page Global Reader Configuration OptionsAdding a Tag to the System Removing a Tag from the SystemAnterus Tags Configuration Options Tag Configuration Options Global RegisterViewing Tag Details Tag Details PopupReader Configuration Pages Reader Configuration Page with Reader 205 selectedReader Configuration Options Reader ConfigurationTag Configuration Options Reader Configuration Status Acquired/OfflineAnterus Duet Module Overview Implementing the Anterus Duet ModuleNetLinx Send Commands Send CommandsAxLink Programming Overview Port Mapping?AP AXLink Channels AXLink ChannelsChannel Type Function Description AXLink Levels AXLink LevelsType Function Description Programming Anterus Rfid Solution Programming Anterus Rfid Solution It’s Your World Take Control