ANT-TAG Device/Asset Tag

The ANT-TAG Device/Asset Tag (FG5172-01) attaches to devices to identify and track location, and trigger system events (FIG. 4). .

FIG. 4 ANT-TAG Device/Asset Tag

Attach the ANT-TAG to a stationary or mobile asset to monitor the location of the asset. A tagged asset may be a non-controllable object not traditionally connected to a Master Control System, or a mobile device that is regularly moved throughout a facility.

ANT-TAG Product Specifications

ANT-TAG Specifications

RF Specifications:

• Tx Frequency: 433 Mhz

 

• Field strength: < 1600 µV/m

 

• Modulation: ASK

 

• Stability: Saw Stabilized

 

• External Antenna

 

 

Electrical Specifications:

• Power: Internally powered Lithium Battery (non-replaceable)

 

• Battery Life span: approximately 5 years.

 

Note: All of the Anterus RFID tags run on non-replaceable batteries, which

 

provide approximately five years of normal use. Additional and replacement tags

 

are available from AMX. Contact your customer service representative for

 

details.

 

 

Environmental:

• Operational temperature: 32º F to 140º F (0º C to 60º C)

 

• Storage temperature: -4º F to 158º F (-20º C to 70º C)

 

• Humidity: 5% to 90% (non condensing)

 

 

Enclosure:

• ABS (ultrasonically sealed) IP 65

 

• Charcoal Grey

 

 

Dimensions (HWD):

2.52" x 1.18" x .35" (64 mm x 30 mm x 9 mm)

 

 

Weight:

0.8 oz. (22.68 grams)

 

 

Certifications:

This device complies with Part 15 of the FCC Rules. Operation is subject to the

 

following two conditions:

 

• This device may not cause harmful interference, and,

 

• This device must accept any interference received, including interference that

 

may cause undesired operation.

 

The following standards applied in accordance with Article 5 of the directive,

 

1999/5/EC:

 

• EN 300 220-1 V1.2.1 (1997-11)

 

• ETS 300 683 (1997-03)

 

Any modification of this device without the express consent of the manufacturer

 

could void the user authority to operate the equipment.

 

 

Anterus RFID Solution

5

 

 

Image 9
Contents Anterus AMX Limited Warranty and Disclaimer Table of Contents Anterus Configuration Manager Overview Anterus Rfid Solution Anterus Rfid Group ANT-RDR Rfid ReaderANT-RDR Product Specifications ANT-RDR Mounting/InstallationANT-RDR Specifications Anterus Rfid Tags Rfid Tags Internal BatteryANT-TAG Product Specifications ANT-TAG SpecificationsANT-TAG Device/Asset Tag ANT-TAG Mounting/Installation ANT-BDG ID Badge TagANT-TAG Antenna Orientation ANT-BDG Mounting/Installation ANT-BDG Product SpecificationsANT-BDG Specifications ANT-BDG Antenna OrientationEnvironmental Factors Signal Strength Behavior of AMX Rfid Tags and ReadersNon-Ideal Antenna Gain Antenna ElevationPeople and Objects AnalysisMultipath Fading Measured DataConclusions Signal Strength Count BehaviorConnecting Additional ANT-RDRs Connecting the ANT-RDR To a NetLinx MasterPower Distribution Wiring GuidelinesCalculating AXlink wiring distances Cable Types and Maximum DistancesDevice DIP Switch Settings Gauge/resistance factors Solid Copper WiringWire gauge Wire Resistance/foot Assigning the ANT-RDR Device AddressInstallation Anterus Rfid Solution Accessing the Rfid Configuration Manager Anterus Configuration ManagerOpen the Manage Devices tab FIG Rfid Configuration Manager page FIG Rfid Configuration Manager MainRfid Configuration Manager Global Register Global RegisterGlobal Register page Global Reader Configuration Options Global Reader Configuration OptionsRemoving a Tag from the System Adding a Tag to the SystemTag Configuration Options Global Register Anterus Tags Configuration OptionsTag Details Popup Viewing Tag DetailsReader Configuration Page with Reader 205 selected Reader Configuration PagesReader Configuration Reader Configuration OptionsStatus Acquired/Offline Tag Configuration Options Reader ConfigurationImplementing the Anterus Duet Module Anterus Duet Module OverviewSend Commands NetLinx Send CommandsAxLink Programming Overview Port Mapping?AP AXLink Channels AXLink ChannelsChannel Type Function Description AXLink Levels AXLink LevelsType Function Description Programming Anterus Rfid Solution Programming Anterus Rfid Solution It’s Your World Take Control