AMX Anterus manual Reader Configuration Options

Page 29

Anterus Configuration Manager

Reader Configuration Options

The top section of this page provides configuration options for the selected ANT-RDR:

FIG. 26 Reader Configuration Options

Reader Configuration Page

• Reader ID:

Indicates the Device ID for the selected ANT-RDR, as specified via the

Reader Address:Indicates the AxLink Device Address for the selected ANT-RDR. In the Global Registery page, the Reader ID is always "Global", and cannot be changed.

Acquired Threshold (1...255): The ANT-RDR will notify the Master that a Tag's signal has been acquired when its RSSI signal is above the Acquired Threshold value.

The allowed range is 1 (min.) to 255 (max)

Default = 200

Lost Threshold (0...254): The ANT-RDR will notify the Master that a Tag's signal has been lost when its RSSI signal is below the Lost Threshold value.

The allowed range is 0 (min.) to 254 (max)

Default = 50

• Sensitivity (1...255)

The Sensitivity setting is used to reduce the message traffic between the

 

ANT-RDR and the Master:

 

The ANT-RDR remembers the last RSSI value sent to the Master for each

 

Tag it has acquired. On the next poll, only Tags whose current RSSI value is

 

outside the range of the last sent RSSI value +/- the Sensitivity value

 

entered here will be sent to the Master.

The allowed range is 1 (min.) to 255 (max)

Default = 30

Tag-Lost Timeout (30...255 Use this option to specify the period time allowed to continue monitoring

seconds)

Tags whose RFID signal has dropped below the level specified in the Lost

 

Threshold.

 

• If a Tag’s RSSI signal has dropped below the Lost Threshold level, and is

 

re-acquired by the Reader within the time period specified here, it will

 

automatically resume normal functionality.

 

• Conversely, if a Tag’s RSSI signal drops below the Lost Threshold level,

 

and is not re-acquired within the specified time period, the Reader will no

 

longer monitor for that Tag. Therefore, once the timeout period has

 

elapsed, the Tag will not be automatically re-acquired, and must be

 

manually re-entered into the system.

 

• Default = 30 seconds.

 

 

• Status (Online/Offline)

Indicates the current status of the selected ANT-RDR (display-only).

Anterus RFID Solution

25

 

 

Image 29
Contents Anterus AMX Limited Warranty and Disclaimer Table of Contents Anterus Configuration Manager Overview Anterus Rfid SolutionAnterus Rfid Group ANT-RDR Rfid ReaderANT-RDR Specifications ANT-RDR Product SpecificationsANT-RDR Mounting/Installation Anterus Rfid Tags Rfid Tags Internal BatteryANT-TAG Device/Asset Tag ANT-TAG Product SpecificationsANT-TAG Specifications ANT-TAG Antenna Orientation ANT-TAG Mounting/InstallationANT-BDG ID Badge Tag ANT-BDG Mounting/Installation ANT-BDG Product SpecificationsANT-BDG Specifications ANT-BDG Antenna OrientationEnvironmental Factors Signal Strength Behavior of AMX Rfid Tags and ReadersNon-Ideal Antenna Gain Antenna ElevationPeople and Objects AnalysisMultipath Fading Measured DataConclusions Signal Strength Count BehaviorConnecting Additional ANT-RDRs Connecting the ANT-RDR To a NetLinx MasterPower Distribution Wiring GuidelinesCalculating AXlink wiring distances Cable Types and Maximum DistancesDevice DIP Switch Settings Gauge/resistance factors Solid Copper WiringWire gauge Wire Resistance/foot Assigning the ANT-RDR Device AddressInstallation Anterus Rfid Solution Accessing the Rfid Configuration Manager Anterus Configuration ManagerOpen the Manage Devices tab FIG Rfid Configuration Manager page FIG Rfid Configuration Manager MainRfid Configuration Manager Global Register Global RegisterGlobal Register page Global Reader Configuration Options Global Reader Configuration OptionsRemoving a Tag from the System Adding a Tag to the System Tag Configuration Options Global Register Anterus Tags Configuration OptionsTag Details Popup Viewing Tag DetailsReader Configuration Page with Reader 205 selected Reader Configuration PagesReader Configuration Reader Configuration OptionsStatus Acquired/Offline Tag Configuration Options Reader ConfigurationImplementing the Anterus Duet Module Anterus Duet Module OverviewSend Commands NetLinx Send CommandsAxLink Programming Overview Port Mapping?AP Channel Type Function Description AXLink ChannelsAXLink Channels Type Function Description AXLink LevelsAXLink Levels Programming Anterus Rfid Solution Programming Anterus Rfid Solution It’s Your World Take Control