Anterus Configuration Manager

The lower section of this page provides configuration options for each Tag assigned to this Reader:

Tag Configuration Options (Reader Configuration Page)

• Tag ID:

Indicates the Tag ID assigned to each Tag (display-only).

 

 

• Name:

Use this field to assign a friendly name to each Tag.

 

 

• Detail:

Click the Detail icon to access a popup window containing detailed info on

 

the selected Tag (see the Viewing Tag Details section on page 23).

 

 

• Info:

Use this field to assign a descriptive string to each Tag.

 

 

• Acquired Threshold

The Tag’s Acquired Threshold value works in conjunction with the Reader's

 

Acquired Threshold setting, and can be used to further filter active RFID

 

Tag messages (via the Reader's Filter Tag Levels option).

 

Note: The Tag’s Acquired Threshold value does not override filtering

 

already configured on the Reader.

 

 

• Status (Acquired/Offline):

Indicates the current status of the selected Tag (display-only).

 

Acquired indicates that the Tag has been detected by the Reader and is

 

currently being tracked by the RFID Reader.

 

Offline indicates that the Tag has moved out of range, and is currently

 

below the Acquired Threshold

 

 

• Delete

Click to remove any Tag from the ANterus system.

 

 

The Tag configuration options on this page are identical to those presented on the Global Register page (see FIG. 19 on page 19).

Settings made to a specific Tag (in the Reader Configuration page - FIG. 25) will override the Global settings made in the Global Registry page.

26

Anterus RFID Solution

Image 30
Contents Anterus AMX Limited Warranty and Disclaimer Table of Contents Anterus Configuration Manager Anterus Rfid Solution OverviewANT-RDR Rfid Reader Anterus Rfid GroupANT-RDR Product Specifications ANT-RDR Mounting/InstallationANT-RDR Specifications Rfid Tags Internal Battery Anterus Rfid TagsANT-TAG Product Specifications ANT-TAG SpecificationsANT-TAG Device/Asset Tag ANT-TAG Mounting/Installation ANT-BDG ID Badge TagANT-TAG Antenna Orientation ANT-BDG Specifications ANT-BDG Product SpecificationsANT-BDG Mounting/Installation ANT-BDG Antenna OrientationNon-Ideal Antenna Gain Signal Strength Behavior of AMX Rfid Tags and ReadersEnvironmental Factors Antenna ElevationMultipath Fading AnalysisPeople and Objects Measured DataSignal Strength Count Behavior ConclusionsConnecting the ANT-RDR To a NetLinx Master Connecting Additional ANT-RDRsCalculating AXlink wiring distances Wiring GuidelinesPower Distribution Cable Types and Maximum DistancesWire gauge Wire Resistance/foot Gauge/resistance factors Solid Copper WiringDevice DIP Switch Settings Assigning the ANT-RDR Device AddressInstallation Anterus Rfid Solution Anterus Configuration Manager Accessing the Rfid Configuration ManagerOpen the Manage Devices tab FIG Rfid Configuration Manager Main Rfid Configuration Manager page FIGRfid Configuration Manager Global Register Global RegisterGlobal Reader Configuration Options Global Register page Global Reader Configuration OptionsAdding a Tag to the System Removing a Tag from the SystemAnterus Tags Configuration Options Tag Configuration Options Global Register Viewing Tag Details Tag Details PopupReader Configuration Pages Reader Configuration Page with Reader 205 selectedReader Configuration Options Reader ConfigurationTag Configuration Options Reader Configuration Status Acquired/OfflineAnterus Duet Module Overview Implementing the Anterus Duet ModuleAxLink Programming Overview NetLinx Send CommandsSend Commands Port Mapping?AP AXLink Channels AXLink ChannelsChannel Type Function Description AXLink Levels AXLink LevelsType Function Description Programming Anterus Rfid Solution Programming Anterus Rfid Solution It’s Your World Take Control