AMX Anterus Cable Types and Maximum Distances, Wiring Guidelines, Pre-manufactured AXlink cable

Page 16

Installation

Wiring Guidelines

The interface requires a 12 VDC power to operate properly. The interface uses a PSN2.8 power supply. The Central Controller supplies power via the AXlink cable or external 12 VDC power supply. The maximum wiring distance between the Central Controller and interface is determined by power consumption, supplied voltage, and the wire gauge used for the cable.

Cable Types and Maximum Distances

Compatible AXlink cable types include those manufactured by Liberty Wire & Cable Inc., and cables that comply with Category 5 or Belden 8102 standards. To determine the maximum distances, refer toPower Distribution section on page 12.

Pre-manufactured AXlink cable

The Liberty Wire & Cable Inc. manufactures AXlink cable that contains two pairs of conductors. The data pairs comprise 22 AWG stranded shielded twisted pair (STP) with a single drain wire, and a 12 VDC power pair of 18 AWG stranded wire. The nominal capacitance between the data conductors is 12.5 pF/ft.

Using the Liberty Wire & Cable Inc. AXlink cable, the maximum overall cable distance between the Central Controller and all external devices for data communication is 3,000 feet with no remote power.

You can contact Liberty Wire & Cable Inc. at 4630 Forge Road, Suite A, Colorado Springs, CO 80907 or by calling (800) 530-8998.

Power Distribution

The following table lists the maximum cable lengths by electrical current and wire gauges (AWG). These distances are based on a min. of 13.5 volts available at the Central Controller's power supply.

Maximum AXlink current and cable lengths by wire AWG

Maximum Current

Cable length by wire AWG

 

 

 

 

 

 

Milliampere (mA)

18 AWG

20 AWG

22 AWG

24 AWG

 

 

 

 

 

50

2,347

1,485

926

584

 

 

 

 

 

100

1,174

743

463

292

 

 

 

 

 

250

469

297

185

117

 

 

 

 

 

500

235

149

93

58

 

 

 

 

 

1,000

117

74

46

29

 

 

 

 

 

Calculating AXlink wiring distances

All AXlink devices require a minimum of 12 VDC power to operate properly. The power can be supplied by the Central Controller's AXlink cable (remote power configuration) or with an optional 12 VDC power supply (local power configuration). The maximum wiring distance between the power supply and AXlink device is determined by power consumption, supplied voltage, and the wire gauge used for the cable. Use the three-step formula below to calculate the maximum wiring lengths allowable between the Central Controller and external AXlink devices.

Most power supplies are factory set to 13.5 VDC. Never use a power supply that exceeds 18 VDC for remote or local power configurations. Contact AMX for a complete list of products and their power consumption ratings.

12

Anterus RFID Solution

Image 16
Contents Anterus AMX Limited Warranty and Disclaimer Table of Contents Anterus Configuration Manager Anterus Rfid Solution OverviewANT-RDR Rfid Reader Anterus Rfid GroupANT-RDR Mounting/Installation ANT-RDR Product SpecificationsANT-RDR Specifications Rfid Tags Internal Battery Anterus Rfid TagsANT-TAG Specifications ANT-TAG Product SpecificationsANT-TAG Device/Asset Tag ANT-BDG ID Badge Tag ANT-TAG Mounting/InstallationANT-TAG Antenna Orientation ANT-BDG Product Specifications ANT-BDG Mounting/InstallationANT-BDG Specifications ANT-BDG Antenna OrientationSignal Strength Behavior of AMX Rfid Tags and Readers Environmental FactorsNon-Ideal Antenna Gain Antenna ElevationAnalysis People and ObjectsMultipath Fading Measured DataSignal Strength Count Behavior ConclusionsConnecting the ANT-RDR To a NetLinx Master Connecting Additional ANT-RDRsWiring Guidelines Power DistributionCalculating AXlink wiring distances Cable Types and Maximum DistancesGauge/resistance factors Solid Copper Wiring Device DIP Switch SettingsWire gauge Wire Resistance/foot Assigning the ANT-RDR Device AddressInstallation Anterus Rfid Solution Anterus Configuration Manager Accessing the Rfid Configuration ManagerOpen the Manage Devices tab FIG Rfid Configuration Manager Main Rfid Configuration Manager page FIGRfid Configuration Manager Global Register Global RegisterGlobal Reader Configuration Options Global Register page Global Reader Configuration OptionsAdding a Tag to the System Removing a Tag from the SystemAnterus Tags Configuration Options Tag Configuration Options Global RegisterViewing Tag Details Tag Details PopupReader Configuration Pages Reader Configuration Page with Reader 205 selectedReader Configuration Options Reader ConfigurationTag Configuration Options Reader Configuration Status Acquired/OfflineAnterus Duet Module Overview Implementing the Anterus Duet ModuleNetLinx Send Commands Send CommandsAxLink Programming Overview Port Mapping?AP AXLink Channels AXLink ChannelsChannel Type Function Description AXLink Levels AXLink LevelsType Function Description Programming Anterus Rfid Solution Programming Anterus Rfid Solution It’s Your World Take Control