Getting Started

Getting Started

Step 1: Downloading The ALD-H48 Workspace

First you must attain the ALD-H48 Workspace file (.AXW). To download the Duet module go to either amx.com > Dealers > InConcert or the Product Catalog page for the ALD-H48. From the InConcert page you can search for and download the ALD-H48 Duet module, they are indicated by the D within the legend displayed below.

FIG. 1 Module Legend

Included in the .AXW file:

The NetLinx Main Code (.AXS)

The Duet module (.JAR)

Associated TPD4 files

Step 2: Setting The ALD-H48 IP Address

In order for the NetLinx Master to locate the ALD-H48, you must set the IP address for the device.

1.Connect your PC to the H48 serial port using a standard DB-9 serial cable.

2.Open your preferred serial client (HyperTerm, TELNET, etc...)

3.Make sure your serial connection baud rate and handshaking settings match the H48 serial settings. (Default Baud Rate 9600, Data Bits: 8, Parity: None, Stop Bits: 1, Flow Control: None)

4.Upon a successful connection, you are prompted with L232>. At the prompt type SETIP,1, xxx.xxx.xxx.xxx . Follow the onscreen instructions from this point.

(Where 1 is the number of processors present on the H48 and xxx.xxx.xxx.xxx is the IP address to be decided by you.)

Further, at the prompt type HELP and a list of all supported command is displayed. In order to get the correct syntax to set the IP address type at the prompt HELP, SETIP.

Step 3: Opening The ALD-H48 Workspace

After you have downloaded the ALD-H48 Workspace file you need to open your NetLinx project. The .AXW file provided by AMX is intended to be a starting point for your ALD-H48 project.

1.Launch NetLinx Studio v2.3 or higher.

2.Select File > Open Workspace to launch the Open Workspace dialog.

3.Browse to the location where you saved the ALD-H48 Workspace file (.AXW) and click Open.

4.Manually enter the IP address assigned to the ALD-48 within Lutron_H48_UI.axs and then recompile the project before transferring it to the NetLinx Master.

ALD-H48 Lighting Controller

3

 

 

 

 

Image 9
Contents ALD-H48 AMX Limited Warranty and Disclaimer Software License and Warranty Agreement Page Table of Contents Via Via Ethernet Overview Overview Getting Started Setting The ALD-H48 IP AddressDownloading The ALD-H48 Workspace Opening The ALD-H48 WorkspaceClick Select All Transferring The ALD-H48 Project to a NetLinx MasterAddressing The Dimmers via The Web Interface Using The Web InterfaceDimmer Address Dimmer Control Controlling Dimmers via The WebScene Establishing And Modifying ScenesModify Scene Modify Group Establishing And Modifying GroupsTouch Panel Main Using The Touch Panel PagesDimmer Light Adjustment Setup SetupAddressing Dimmers GroupsCreating a Group Scenes ScenesCreating a Lighting Scene Using The Touch Panel Pages Advanced Programming IntroductionOverview Definedevice ImplementationChannel Assignment and Feedback Port MappingChannel Assignment and Feedback Command Interface =STOP KEYPADENABLE-1 KEYPADENABLE-2?FWVERSION ?KEYPADADDR-1KEYPADREMOVEADDR-151 KEYPADREMOVEIDX-1?LIGHTADDR-1 ?LIGHTLEVEL-1 LIGHTLEVEL-1,102LIGHTRAMP-1,UP LIGHTRAMP-1,STOP LIGHTREMOVEIDX-2 LightremoveaddrReinit ?LIGHTSTATE-1?VERSION Command Feedback KEYPADBTN-1,DOUBLECLICK KEYPADENABLE-1LIGHTSTATE-1,ON Device Notes Programming Notes 14111 14112 11411114112 Adding Functions to Modules Commands to The DeviceUpdating The ALD-H48 Firmware ViaVia Ethernet RevisionLast05/11/05