Specifications

Product

The following table shows the product specifications for the

specifications

5 Port 10Base-T Hub.

 

 

 

 

 

 

 

Item

 

Specification

 

 

 

 

 

Power

 

 

 

 

 

 

 

Input voltage range:

 

18 – 30 VDC

 

 

 

 

 

Maximum current draw:

 

45 mA

 

 

 

 

 

Physical

 

 

 

 

 

 

 

Size (H × W × D):

 

1.46 × 4.75 × 4.30 in

 

 

 

(3.7 × 12.1 × 10.9 cm)

 

 

 

 

 

Weight:

 

0.25 lb (0.11 kg)

 

 

 

 

 

Shipping weight:

 

0.65 lb (0.30 kg)

 

 

 

 

 

Environmental

 

 

 

 

 

 

 

Elevation (above MSL):

 

0 to 10,000 ft (0 to 3000 m)

 

Operating

 

 

 

0 to 50,000 ft (0 to 15 000 m)

 

Storage

 

 

 

 

 

 

 

 

 

Temperature:

 

32 to 122°F (0 to 50°C)

 

Operating

 

 

 

5 to 158°F (-15 to 70°C)

 

Storage

 

 

 

 

 

 

 

 

 

Relative humidity:

 

0 to 95%, non-condensing

 

Operating

 

 

 

0 to 95%, non-condensing

 

Storage

 

 

 

 

 

 

 

 

 

 

Approvals/Standards

FCC, Part 15, Class B

EN 55 022 (CISPR 22), Class B

VCCI Class 2

IEC 1000-4-2, 3, 4

CE

C-Tick

IEEE 802.3 10Base-T

Port Configuration: Station Ports are MDI-X, Uplink port is MDI

Table 3: Product Specifications

14

Image 18
Contents Port 10Base-T Hub Thank You Contents Page Introduction SmartSlot 5-Port 10Base-T Hub is an APC accessoryLAN by installing it in the SmartSlot of an APC UPS or That allows you to expand or create a local area networkProduct Description For a description of the conditions indicated by LEDs Label Color Activity DescriptionWays, as shown in Figure Munication cable for each device to be attachedInstalling the Hub Turn off the ON/OFF switch on the front Shut down and power off the connectedTurn off the System Enable switch on If present, unplug the Triple Chassis’s powerBack panel of the UPS or triple chassis. Keep Use a #2 Phillips head screwdriver to removeScrews fastening the SmartSlot cover plate to Screws for below. Save the SmartSlot coverPlug the UPS back into the AC power outlet Using straight-through UTP cables, connect the StaProcedure listed below Press and hold the Power On button until youInstallation Procedure As many as 32 stations, as shown below in . Note Use of a crossover cable to connect the Uplink ports2 central hubs Removing the Hub Troubleshooting Provides suggestions for troubleshooting your hubAction Cause Solution Troubleshooting Suggestions Specifications Port 10Base-T HubWarranty Information Technician will help solve the problem over ProcedureBe prepared to provide a description of the problem Authorization RMA numberConformity is Application of CouncilDirectives Standards to Which DeclaredW. a p c c . c o m