| Installation and Safety Guide |
Table 1: System LEDs (Continued) | ||
|
|
|
LED | State | Description |
|
|
|
PSU 2 | Green | PSU 2 is installed and supplying power to the switch. |
|
| The voltage output is within specification. |
|
|
|
| Red | PSU 2 is installed in the switch and has exceeded its |
|
| recommended temperature threshold of 75º C |
|
| (167º F), or the fan has failed. |
|
| A FOM is installed in the switch and has failed. |
|
| The bay is empty. |
|
|
|
| Off | A FOM is installed and operating at an acceptable |
|
| speed. |
|
|
|
Fault | Red | The switch or management software is |
|
| malfunctioning. |
|
|
|
| 1 Flash | One or more heatsink fans has failed or is operating |
|
| below the recommended speed. |
|
|
|
| 6 Flashes | The switch’s temperature has exceeded the |
|
| recommended threshold. After flashing six times, |
|
| the LED stops briefly, then repeats the sequence. |
|
|
|
| Slow | The SDRAM (DIMM) has not been detected. |
| flashing at |
|
| startup |
|
|
|
|
| Rapid | The SDRAM (DIMM) is not compatible with the |
| flashing at | switch. |
| startup |
|
|
|
|
CF | Green | The CompactFlash memory card is active and |
| flashing | should not be ejected. The card can be safely ejected |
|
| when the LED remains off. |
|
|
|
SD | Off | Secure Digital memory card. Not supported by 3.0.1 |
|
| software. |
|
|
|