Installation and Safety Guide
The adjustable bracket extensions are rotationally symmetrical when attached to the rear brackets. When viewed from the rear of the switch, the flanges on the bracket extensions are at the bottom on the right and at the top on the left. This allows adequate clearance when a power supply unit or
9.Attach the adjustable bracket extensions to the rack using rack mounting screws.
10.Tighten the nuts that secure the adjustable bracket extensions to the rear brackets.
11.Check that all screws and nuts are fully tightened.
Applying Power to the Switch
The switch has two bays in the rear. Your switch comes with one
AC power supply
Important information for service personnel:
■CAUTION: double pole/neutral fusing
■the rating of fuses FH101 and FH102 is 250 V, 5 A
Procedure for AC power supply
To apply power to the PSU, plug the AC power cord that is provided into the power inlet on the faceplate of the PSU. Then connect the power cord to the main power supply.
DC supply cable and power supply
Supply cable specifications
■
■minimum core size: 3.3 mm2 (12 AWG) high strand count copper wire
■minimum cable rating: 600 V, 90 degrees C
Power supply specifications
■40 to 60 V, 48 V nominal
■supports either positive grounded or negative grounded operation
■a 15 Amp certified/listed circuit breaker is required for circuit protection
9