5.Change the password.

Change the password as soon as possible because a manager account with the default password is a serious security risk. Remember the new password because there is no way to retrieve it if you forget it.

To change the account password, use the set password command.

6.Display help for commands as necessary.

To display a list of help topics, use the help command.

To display help on a specific topic, use the help <topic> command.

Alternatively, display a list of valid options by typing a question mark at the end of a partial command.

Checking LEDs

Table 1 describes how LEDs on the switch report faults and operational activities.

Table 2 on page 14 describes how LEDs on power supply units and fan-only modules report faults and operational activities.

LEDs for Ethernet ports and Small Form Factor Pluggable (SFP) ports are described in the Hardware Reference.

Table 1: System LEDs

LED

State

Description

 

 

 

PSU 1

Green

PSU 1 is installed and supplying power to the switch.

 

 

The voltage output is within specification.

 

 

 

 

Red

PSU 1 is installed in the switch and has exceeded its

 

 

recommended temperature threshold of 75º C

 

 

(167º F), or the fan has failed.

 

 

A FOM is installed in the switch and has failed.

 

 

The bay is empty.

 

 

 

 

Off

A FOM is installed and operating at an acceptable

 

 

speed.

 

 

For AT-9924T and AT-9924SP models, this LED is

 

 

always off because a FOM is not required.

 

 

 

12

Image 12
Contents Installation and Safety Guide Page Contents Package Contents Models Covered by this GuideSelecting a Site Installing the Switch Before you beginInstalling the switch using the 19-inch rack-mount kit Adjustable bracket Applying Power to the Switch AC power supplyProcedure for DC power supply Connecting the Switch Using the CLI to configure a switchChecking LEDs LEDPSU Below the recommended speed Documentation CD PWRStandards This product meets the following standardsElectrical Safety Statements Elektrische SicherheitSafety Electrical NoticesLightning Danger Lightning Activity Electrical Type Class 1 EquipmentSicherheit Achtung Gefährliche SpannungGefahr Durch Blitzschlag VorsichtNetzsicherung Vorsicht RahmeneinbauSikkerhed Elektriske Forholdsregler Fare Under UvejrLynaktivitet Elektrisk Klasse 1-UDSTYR ELEKTRISK-OVERBELASTNING AF SpændingskredsløbetVeiligheid Gevaar Voor BlikseminslagElektrische Toestellen VAN Klasse Sécurité Information SUR LES Risques ÉlectriquesAvertissement Danger D’ÉLECTROCUTION Équipement DE Classe 1 Électrique Turvallisuus Sähköön Liittyviä HuomautuksiaVaroitus Sähköiskuvaara Salamaniskuvaara Sähkö Tyyppiluokan 1 LaitteetSÄHKÖ-VAIHTORVIRTASÄHKÖPIIRIN Ylikuormitus Norme di Sicurezza Avvertenze ElettricheAttenzione Pericolo DI Scosse Elettriche Pericolo DI FulminiElettricità Dispositivi DI Classe Sikkerhet ElektrisitetFare for Lynnedslag Elektrisk Type 1- Klasse UtstyrElektrisk Overbelastning PÅ AC Hovedkretsløp Segurança Avisos Sobre Características ElétricasAtenção Perigo DE Choque Elétrico Perigo DE Choque Causado POR RaioInstallation and Safety Guide Seguridad Avisos ElectricosAdvertencia Peligro DE Electrochoque Peligro DE RayosInstallation and Safety Guide Säkerhet Tillkännagivanden Beträffande ElektricitetsriskFara FÖR Blixtnedslag Elektriskt TYP Klass 1 UtrustningPage EC Declaration of Conformity NEW Zealand