Here is a brief description of each menu and sub option, and what the default values should be. The SEG device is factory set to have the highest security possible. Changing any options, especially in the 'Security' menu could result in not having a completely secure environment.

0 – Sever Configuration

 

(XXX).(XXX).(XXX).(XXX) Allows you to set the IP address of the SEG directly. You

 

can set it to 0.0.0.0 to allow it to be served a dynamic IP address each time it boots up.

IP Address

The IP address should only be set to 0.0.0.0 if the DHCP server is assigning the same IP

 

address to this SEG device every time, by way of using a non-expiring IP address lease

 

that is assigned to the MAC address of the device.

Set Gateway IP Address

N (Do Not Change); The term 'Gateway' here refers to a network router on the LAN not

the device you are configuring here.

 

 

 

Netmask

0 (Do Not Change)

Change Telnet Config Password N (it is recommended that you change this option to Yes, and then set a 4 digit password)

1 – Channel 1 Configuration: Settings of the RS-232 Port

Baud Rate

1200 (Do Not Change)

 

 

I/F Mode

4C (Do Not Change)

 

 

Flow

00 (Do Not Change)

 

 

Use UDP

Y (Do Not Change)

 

 

Source Port

09997 (If there is a need to change this then make sure to change the site settings within

Hub Manager Professional to match)

 

 

 

Destination Port

00000 (Do Not Change)

 

 

Destination IP

0.0.0.0 (Do Not Change)

 

 

2 - Channel 2 Configuration: Settings of the RS-485 Port

Baud Rate

19200 (Do Not Change)

 

 

I/F Mode

4C (Do Not Change)

 

 

Flow

00 (Do Not Change)

 

 

Document Number: 6066005, Rev 3.2

Page 25 of 34

Image 25
Contents Ordering Information Secure Ethernet Gateway SEG-1 and SEG-MTable of Contents LED Status Product SpecificationsSEG-1 Diagrams Hardware InstallationSEG-1 to HubMax/Hub MiniMax Connection Method Connection the SEG-1 to a HubMax or Hub MiniMax RS-232SEG-1 to HC500P Connection Method Connecting the SEG-1 to HC500P RS-232Connecting Multiple HubMax/Hub MiniMax Networks SEG-1 to prox.pad plus Connection Method Connecting the SEG-1 to a prox.pad plus RS-485Connecting Multiple prox.pad plus Networks Connecting the SEG-1 to a Max 3 System RS-485 Connecting the SEG-1 to a MiniMax 3 System RS-485 SEG-M Diagram SEG-M Installation Plug On ModuleSEG-M LED Indicators SEG-M ConnectorsConnector Description Pin Configuration Label Pin Label DescriptionConnecting the SEG-M to a Hub MiniMax System RS-232 Connecting the SEG-M to a HubMax System RS-232Connecting the SEG-M to a Max 3 System RS-485 Connecting the SEG-M to a MiniMax 3 System RS-485 MAC Address Description SEG ConfigurationNo SEG parameters defined Found SEGs are displayed in grid Generate Security Key Dynamic IP Address, non-expiring leaseStatic IP Address Document Number 6066005, Rev Document Number 6066005, Rev SEG Setup Menu Channel 1 Configuration Settings of the RS-232 Port Sever ConfigurationChannel 2 Configuration Settings of the RS-485 Port Security Factory DefaultsExit Without Save Save and ExitSEG Parameters Generate Default Security Key Defaulting the SEG SettingsReset the Security Key in the SEG to all 0s Generate Random Security KeyReset the Security Key in the PC to all 0s Trouble Shooting Document Number 6066005, Rev Document Number 6066005, Rev FCC Compliance Statement