Linksys SRW208MP, SRW208L, SRW208G, SRW208P manual Statistics Rmon Events, Add Event

Page 35

Chapter 5

•• Port  Displays the RMON statistics for the selected port.

•• LAG  Displays the RMON statistics for the selected LAG.

Counter Name  Displays the selected MIB variable.

Sample Type  Defines the sampling method for the selected variable and comparing the value against the thresholds. The possible field values are:

•• Absolute  Compares the values directly with the thresholds at the end of the sampling interval.

•• Delta  Subtracts the last sampled value from the current value. The difference in the values is compared to the threshold.

Rising Threshold  Displays the rising counter value that triggers the rising threshold alarm. The rising threshold is presented on top of the graph bars. Each monitored variable is designated a color.

Rising Event  Displays the mechanism in which the alarms are reported. The possible field values are:

•• LOG  Indicates there is not a saving mechanism for either the device or in the management system. If the device is not reset, the entry remains in the Log Table.

•• TRAP  Indicates that an SNMP trap is generated, and sent via the Trap mechanism. The Trap can also be saved using the Trap mechanism.

•• Both  Indicates that both the Log and Trap mechanism are used to report alarms.

Falling Threshold  Displays the falling counter value that triggers the falling threshold alarm. The falling threshold is graphically presented on top of the graph bars. Each monitored variable is designated a color.

Falling Event  Displays the mechanism in which the alarms are reported. The possible field values are:

•• LOG  Indicates there is not a saving mechanism for either the device or in the management system. If the device is not reset, the entry remains in the Log Table.

•• TRAP  Indicates that a SNMP trap is generated, and sent via the Trap mechanism. The Trap can also be saved using the Trap mechanism.

•• Both  Indicates that both the Log and Trap mechanism are used to report alarms.

Startup Alarm  Displays the trigger that activates the alarm generation. Rising is defined by crossing the threshold from a low-value threshold to a higher-value threshold.

Interval  Defines the alarm interval time in seconds.

Advanced Configuration

Owner  Displays the device or user that defined the alarm.

The Add to List button adds the RMON Alarms Table entry.

The Alarm Table area contains the following additional field:

Counter Value  Displays the current counter value for the particular alarm.

Statistics > RMON Events

An RMON Event determines the action to take when an alarm is triggered. The response to an alarm can include logging the alarm or sending an SNMP trap message. If the response corresponding to an alarm has not yet been defined, use the RMON Event screen to configure the Event Setting table.

Statistics > RMON Events

Add Event

Event Entry  Displays the event.

Community  Displays the community to which the event belongs.

Description  Displays the user-defined event description. Type  Describes the event type. Possible values are:

•• None  Indicates that no event occurred.

•• Log  Indicates that the event is a log entry.

•• Trap  Indicates that the event is a trap.

•• Log and Trap  Indicates that the event is both a log entry and a trap.

Owner  Displays the device or user that defined the event.

8-Port 10/100 Ethernet Switch with Webview

29

Image 35
Contents Port 10/100 Ethernet Switch with Webview Online Resources About This GuideAbout This Guide Icon DescriptionsTable of Contents Port 10/100 Ethernet Switch with Webview Iii Table of Contents Appendix G Contact Information Appendix B IntroductionAppendix F Regulatory Information Welcome Chapter IntroductionIntroduction SRW208G Front Panel Chapter Product OverviewProduct Overview SRW208 Front PanelSRW208P/SRW208MP Front Panel SRW208L Front PanelBack Panel Placement Options Chapter InstallationInstallation Positioning the SwitchRack-Mount Placement Wall-Mount Placement Hardware Installation Connecting to the Switch through a Telnet Session Chapter Configuration Using Console InterfaceSystem Configuration Menu Switch Main MenuManagement Settings SSH Configuration User & Password Settings IP Configuration Https Configuration Port Status Port ConfigurationHelp Setup Summary Chapter Advanced ConfigurationAdvanced Configuration Accessing the Web-based UtilityPoE Information Setup Network SettingsIP Configuration System InformationPort Management Port Settings Setup TimePort Configuration Detail Link Aggregation Detail Port Management Link AggregationPort Management Lacp Port Management PoE Power SettingsVlan Range Vlan Management Port SettingsVlan Management Create Vlan Single VlanVlan Management Vlan to Ports Vlan Management Ports to VlanJoin Vlan Detail Vlan Management GvrpStatistics Rmon Statistics Log Table Statistics Rmon HistoryRmon History Statistics Rmon AlarmsAdd Event Statistics Rmon EventsStatistics 802.1x Statistics Statistics Port UtilizationACL IP based ACL Statistics Gvrp StatisticsACL MAC based ACL Security Radius Security ACL BindingSecurity TACACS+ Security Ports Security Security 802.1x SettingsSetting Timer Security Multiple Hosts QoS QoS CoS SettingsSecurity Storm Control QoS Bandwidth QoS Queue SettingsQoS Dscp Settings CoS DefaultQoS Advanced Mode QoS Basic ModeNew Class Map Out of Profile DscpPolicy Name New Aggregate Policer Spanning TreeSpanning Tree STP Status Spanning Tree Global STP Global SettingBridge Settings Spanning Tree Rstp Port Settings Spanning Tree STP Port SettingsEstablished by the device Spanning Tree Mstp PropertiesSpanning Tree Mstp Instance Settings Multicast Igmp Snooping Snmp Global Parameters Multicast Bridge MulticastSnmp Views Snmp Group Membership Snmp Group ProfileBase Table Snmp CommunitiesAdvanced Table Snmp Notification FilterSnmp Notification Recipient Admin Static Address Admin User AuthenticationQuery Admin Dynamic AddressAdmin Logging Admin Cable Test Admin Port MirroringVia Tftp Admin Save ConfigurationAdmin Firmware Upgrade BackupAdmin Server Logs Admin RebootAdmin Factory Defaults Admin Flash Logs Admin Memory LogsFiber Optic Cabling Appendix a About Gigabit Ethernet Fiber Optic CablingGigabit Ethernet Appendix B Introduction Startup Menu ProceduresDownloading Using Xmodem Glossary Appendix C GlossaryGlossary Smtp Simple Mail Transfer Protocol The standard e Appendix C Specifications Appendix D SpecificationsQoS Specifications SRW208L SRW208MP Limits Bandwidth Intensive Video Traffic to Only Requestors Support 256 multicast groups Ethernet Exclusions and Limitations Warranty InformationObtaining Warranty Service Technical Support Warranty InformationIndustry Canada Statement Safety NoticesRegulatory Information FCC StatementRegulatory Information Appendix F Norsk Norwegian Miljøinformasjon for kunder i EU Appendix F Contact Information Appendix G