Table 2-1. Steps for Installing the ONline System Concentrator (Continued)

4

Set up the power supply.

Selecting the Power Supply

 

 

Voltage

 

 

 

5

Install the ONline Controller

Installing ONline Modules

 

Module in the concentrator.

 

 

 

 

6

Install media modules in the

Installing ONline Modules

 

concentrator.

 

 

 

 

7

Connect the network

Connecting Network Cables

 

cables to the media

 

 

modules.

 

 

 

 

8

Power up all network

Power Up and Verification

 

devices and verify the

 

 

installation.

 

 

 

 

Installing the Cable Tray

The cable tray that comes standard with the concentrator helps to manage the cables that run from the front of the unit so they are fed under the unit and out through the back. The tray also provides the required space between the bottom of the unit and the next device in the rack (or the top of the table) so there is adequate air flow to cool the unit.

Caution: If you choose not to use the cable tray beneath your unit, you must ensure that 1 3/4" (4.45 cm) of space is open below the ONline unit to ensure adequate incoming airflow (provided by the installed feet).

Installation and Troubleshooting 2 - 7

Image 37
Contents Document Number Printed March VDE Class B Compliance Restricted Rights Page Contents Maintenance Appendix B Slot Usage Chart Appendix C Technical Support Page Figures Page Tables Page Audience How to Use This GuideThis guide contains the following chapters Structure of This GuideConvention Indicates Example Document ConventionsRelated Documents Reference Documents 3Com DocumentsPage Introducing the ONline System Concentrator IntroductionMultiple 17-Slot Concentrator Environment Front Panel Back PanelONline System Concentrator Front View ONline System Concentrator FeaturesModular Design Modular ONline ConfigurationTriChannel Architecture Port-Switching TechnologyONline System Concentrator Using Multiple Networks Backup Power Supply Fault-Tolerance CapabilitiesLoad Sharing Redundant Cable Links Backup Controller ModuleRedundant Cable Link Configuration Backup ConcentratorHot Swapping of Media Modules Backup Concentrator ConfigurationSynchronous Backplane Contents of the Shipping Box Installation and TroubleshootingONline System Concentrator Shipping Box Contents FCC Regulations Location Requirements Site Selection ConsiderationsVentilation Rack Mount Installation Requirements Power RequirementsTable Top Installation Requirements InstallationInstalling the Cable Tray Cable Tray Rack Mounting Rack Mount SettingsRack Mount Positions Cable Tray Table Mounting Cable Tray Installation in RackRack Mounting the ONline System Concentrator Installing the ONline System ConcentratorAttaching the Rack Mount Flanges Chassis Mounted in Rack Table Top Mounting the ONline ConcentratorRemoving Fan Unit Installing the Backup Power Supply OptionalUnplugging the Fan Unit Power Supply Connectors 10. Installed Backup Power Supply Selecting the Power Supply Voltage11. Setting the Voltage Selector Switch Connecting Network Cables Installing ONline Modules12. Network Cable Connections Power Up and VerificationFan Operation Verification Power Supply Operation VerificationTroubleshooting with Controller Module LEDs Command. If this fails to See Primary Power LED Technical Assistance Configuration of your concentrator Where To Go From HereMaintenance Replacing the Power Supply Routine MaintenanceRemoving the Power Supply Unplugging the Power Supply Power Supply Plugs in ONline System Concentrator Backup Power Supply Installed Removing the Fan Unit Replacing the Fan UnitUnplugging the Fan Unit Other System Components ONline Module MaintenancePage Environmental GeneralMechanical Power SourceRegulatory Compliance Accessories Page Slot Usage Chart Table B-1. Concentrator Slot Usage Chart Table B-1. Concentrator Slot Usage Chart Page On-line Technical Support Technical SupportEmail Technical Support Support from Your Network SupplierWorld Wide Web Site Support from 3Com Returning Products for Repair Accessing the 3Com MIB3Com Technical Publications Page Index Index