Rose electronic MAN-VR2 manual Keyboard command description

Page 46

Command

Key

Description

Computer Select

<Ctrl> x

Connects your keyboard, video monitor,

 

+-ctrl+-x

and mouse to the selected computer.

 

(x = 1, 2, 3, 4,

 

 

5, 6, 7, 8)

 

Connect to next

<Ctrl> + (Plus)

Selects the next sequential computer.

computer

+-ctrl+-+

 

Connect to

<Ctrl> - (Minus)

Selects the previous sequential

previous computer

+-ctrl+--

computer.

Computer

<Ctrl> L

Disconnects from computer.

disconnect.

+-ctrl+-l

 

Scan (On)

<Ctrl> S

Turns scan mode on, causing the

 

+-ctrl+-s

Vista Remote 2 to start scanning

 

 

sequentially from the current port

 

 

through the remaining ports and start

 

 

again at Port 1.

Scan (Off)

<Ctrl> X

Turns scan mode off.

 

+-ctrl+-x

 

Reset mouse

<Ctrl> O

Sends reset mouse command to the

command

+-ctrl+-o

currently selected computer. Will recover

 

 

stuck NT mouse

Table 1. Keyboard Commands

Follow each set-up command with the “Keep” command to save the changes. “Keep” command = press and release the left <Ctrl> key, then the “K” key.

Keyboard command description

Computer select

To select a computer from your keyboard, press and release the left <Ctrl> key and then type in the computer number (1-4 or 1-8).

Next computer

To switch to the “Next computer”, press and release the left <Ctrl> key, then press the plus/equal key.

Previous computer

To switch to the “Previous computer”, press and release the left <Ctrl> key then press the minus/underscore key.

Scan mode (On)

To enable the “Scan mode”, press and release the left <Ctrl> key, then type S. The Vista Remote 2 switch will begin scanning sequentially from its current computer through the remaining computers (as set by the maximum computers command), and then begin again at computer 1.

Scan mode (Off)

To stop the “Scan mode”, press and release the left <Ctrl> key and then type “X”. Issuing a computer select command also turns off scanning.

Scan time interval

The “Scan Time interval” command sets the time, in seconds that the Vista Remote 2 switch will pause at each of the computers when scanning. The default setting is 5 seconds. To

40

Vista Remote 2 Installation and Operations Manual

Image 46
Contents Vista Remote Page Limited Warranty FCC / IC STATEMENTS, EU Declaration of Conformity Table of Contents Figures Introduction System IntroductionFeatures Package contentsProduct Registration Rose Electronics web siteOverview System OverviewVista Remote 2 Models Vista Remote 2 ModelsVista Remote 2 Installation InstallationConnecting the KVM station Connecting the Computers Connecting to the networkUnit Configuration Configuring the Vista Remote 2 IP Input moduleFirmware Admin passwordHardware Keyboard LayoutMAC address Network ConfigurationConfiguring the Network Use DHCP/IP address/Net Mask/Gateway/VNC port/HTTP PortSecure Key calculation Restore mouse functions Control menu LogoffAccess mode Connecting RemotelyConfiguration HostRemote Configuration User Accounts User AccountsUnit Configuration Unit Advanced Configuration Upgrade Firmware Single Mouse Mode Mouse SwitchBehavior for admin connections when limit reached Reset UnitTime and Date Configuration Time and Date ConfigurationUse Dhcp Network ConfigurationMAC address IP AddressIP Gateway Host ConfigurationIP Access Control VNC PortUsers Logging and StatusName Hotkey / KVM PortTo copy and paste the log KVM Switch Module Configuration KVM Switch Module OSDChange the computer names Change computer namesForeground/Background color Configure appearanceAppearance options Name x or y positionScreen saver type Name fadeout timeName font Screen saver timeConfigure security Access passwordConfigure mouse type Access timeConfigure keyboard type Configure KeyboardConfigure miscellaneous Scan timeSave ExitOperation Connecting using a web browserRemote System Operation Viewer encryption settings VNC Viewer ToolbarControls Tab Virtual Media Video SettingsSetting the Threshold manually InfoHost Tab Vista Remote 2 Installation and Operations Manual Keyboard commands Keyboard CommandsCommand Key Sequence Description HotKey Command Keyboard command description Keep command ResetReset computer mouse type NT and WIN 2K systems only Mode commandWhen logging on using VNC viewer, I cannot enter a username TroubleshootingTroubleshooting Remote network users are unable to contact the unitMouse driver does not load Computer does not boot, keyboard or mouse error receivedCan’t switch computers from keyboard Wrong or missing characters from those typedVideo not synchronized or wrong color Lower resolution OK, but can’t enter high resolution modeVideo fuzzy On-screen display not synchronizedMaintenance and Repair Technical SupportSafety SafetyGrounding Safety and EMC Regulatory StatementsServicing Appendices Appendix a General specificationsAppendix B Part Numbers Appendix C RackMount Network/Address Appendix D IP Access ControlSetting IP access control Single locationsAddress ranges Vista Remote 2 Installation and Operations ManualMask To edit/remove access control entries AccessTo reorder access control entries Appendix E VNC Viewer connection optionsPreferred encoding Color/EncodingAuto select Color levelScaling InputsMisc Identities Defaults Save Configuration File Save AsDefaults Reload Load / SaveAppendix E VNC viewer window options Appendix F Browser viewer options Encoding and color levelSecurity Appendix G Supported video modes Appendix H Typematic Rate Typematic DelayTypematic Rate Appendix I Hot Key Codes Vista Remote 2 Installation and Operations Manual Page Stancliff Road Phone 281 Houston, Texas