Rose electronic MAN-VR2 manual Remote System Operation, Connecting using a web browser

Page 39

OPERATION

Remote System Operation

Connecting using a web browser

Connecting to the Vista Remote 2 from a network location or over the internet can be done two ways; using the Built-in Java VNC Viewer or Downloading Windows VNC Viewer from the unit and installing it on the remote computer. It is recommended that the Windows VNC viewer be downloaded from the unit and installed on the remote computer. The VNC viewer is more robust than the Java applet and has more functionality and features than the Java applet. If you experience problems using the Java applet, switch to the VNC viewer application.

To connect to the Vista Remote 2 from any workstation, start a web browser and enter the assigned IP address for the unit in the URL field of the browser (Example http://192.168.0.44). The Vista Remote 2 will respond with the below three options displayed in the browser’s window.

The first time a connection to the Vista Remote 2 is made, it is recommended that you download the Windows VNC viewer from the unit, save it and run the VNC viewer to connect to the unit directly. Some operating systems may request permission to run or save the program. Save the program to the location wanted and create a desktop ICON for the program. The next time the RealVNC viewer is needed, just click on the desktop ICON to connect.

After the installation is complete, run the VNC viewer program and the VNC Viewer Connection Details window will display. Make sure that the Server IP address is correct and the port number is 5900. If the port number was changed during the unit configuration procedure, this number will match that VNC port configuration number.

Click on “OK” to enter your Username and Password

Click on the OK tab and VNC Authentication box will display. Enter the Username and password and click OK. Upon validation, the remote connected computer’s video will display. NOTE: If the username or password is entered incorrectly five consecutive times, the remote user station’s IP address is locked out and remote access is denied. The lockout of an IP address will show up in the log as IP address “Blacklisted”. (See the troubleshooting section for the procedure to unlock the IP address)

Click on the OK tab and the remote connected computer’s video will display.

Vista Remote 2 Installation and Operations Manual

33

 

 

 

Image 39
Contents Vista Remote Page Limited Warranty FCC / IC STATEMENTS, EU Declaration of Conformity Table of Contents Figures System Introduction IntroductionPackage contents FeaturesRose Electronics web site Product RegistrationSystem Overview OverviewVista Remote 2 Models Vista Remote 2 ModelsInstallation Vista Remote 2 InstallationConnecting the KVM station Connecting to the network Connecting the ComputersConfiguring the Vista Remote 2 IP Input module Unit ConfigurationKeyboard Layout Admin passwordHardware FirmwareUse DHCP/IP address/Net Mask/Gateway/VNC port/HTTP Port Network ConfigurationConfiguring the Network MAC addressSecure Key calculation Control menu Logoff Restore mouse functionsHost Connecting RemotelyConfiguration Access modeRemote Configuration User Accounts User AccountsUnit Configuration Unit Advanced Configuration Reset Unit Single Mouse Mode Mouse SwitchBehavior for admin connections when limit reached Upgrade FirmwareTime and Date Configuration Time and Date ConfigurationIP Address Network ConfigurationMAC address Use DhcpVNC Port Host ConfigurationIP Access Control IP GatewayHotkey / KVM Port Logging and StatusName UsersTo copy and paste the log KVM Switch Module OSD KVM Switch Module ConfigurationChange computer names Change the computer namesName x or y position Configure appearanceAppearance options Foreground/Background colorScreen saver time Name fadeout timeName font Screen saver typeAccess password Configure securityAccess time Configure mouse type Configure Keyboard Configure keyboard typeScan time Configure miscellaneousExit SaveConnecting using a web browser OperationRemote System Operation VNC Viewer Toolbar Viewer encryption settingsControls Tab Info Video SettingsSetting the Threshold manually Virtual MediaHost Tab Vista Remote 2 Installation and Operations Manual Keyboard Commands Keyboard commandsCommand Key Sequence Description HotKey Command Keyboard command description Mode command ResetReset computer mouse type NT and WIN 2K systems only Keep commandRemote network users are unable to contact the unit TroubleshootingTroubleshooting When logging on using VNC viewer, I cannot enter a usernameWrong or missing characters from those typed Computer does not boot, keyboard or mouse error receivedCan’t switch computers from keyboard Mouse driver does not loadOn-screen display not synchronized Lower resolution OK, but can’t enter high resolution modeVideo fuzzy Video not synchronized or wrong colorTechnical Support Maintenance and RepairSafety SafetySafety and EMC Regulatory Statements GroundingServicing Appendix a General specifications AppendicesAppendix B Part Numbers Appendix C RackMount Single locations Appendix D IP Access ControlSetting IP access control Network/AddressVista Remote 2 Installation and Operations Manual Address rangesMask Appendix E VNC Viewer connection options AccessTo reorder access control entries To edit/remove access control entriesColor level Color/EncodingAuto select Preferred encodingInputs ScalingMisc Identities Load / Save Configuration File Save AsDefaults Reload Defaults SaveAppendix E VNC viewer window options Encoding and color level Appendix F Browser viewer optionsSecurity Appendix G Supported video modes Typematic Delay Appendix H Typematic RateTypematic Rate Appendix I Hot Key Codes Vista Remote 2 Installation and Operations Manual Page Stancliff Road Phone 281 Houston, Texas