Powerware IPK-0318, IPK-0320, IPK-0319 manual Introduction

Page 7

C H A P T E R 1

INTRODUCTION

The BestLink SNMP/WEB Adapter is a network adapter for your uninterruptible power system (UPS) that provides both SNMP and HTTP compatibility, as well as advanced communication with true RS-232.

The BestLink SNMP/WEB Adapter is available in two models: and internal for UPSs with a BestDock slot and external for connection to the UPS serial port. Both models can connect to a twisted-pair Ethernet (10baseT) network using an RJ-45 connector.

SNMP-compatible network management software (user-supplied) may be used to monitor the UPS in a method similar to that of other network devices. Others may wish to use a web browser such as NetscapeZ or Microsoft9 Internet Explorer to monitor and manage the connected UPS.

The adapter also supports remote monitoring and shutdown from UPS-protected computer systems. NetWatch client software for use with a BestLink Adapter is supplied on the Invensys Software Suite CD or on the web at www.powerware.com. Client software is available for Windows995/98/NT/2000, Novell9NetWare9and various versions of UNIX9. These programs communicate through TCP/IP with the BestLink Adapter and automatically shutdown the protected system during extended power outages.

In addition, the BestLink SNMP/WEB Adapter has the following features:

:Configuration from serial port, telnet, or HTTP web browser.

:Management from HTTP web browser or SNMP management software.

:Supports MIB_II and BestLink MIB (bestpwr2.mib) management information bases.

:Firmware upgradable from a Windows utility via a network connection.

:Scheduling function to control UPS shutdowns and startups.

:History log files (data and events) for recording power problems.

:UPS status information available to registered NetWatch clients for automatic shutdown of Windows 95/98/NT/2000, Novell NetWare, and UNIX.

:E-mail notification of changes in the UPS status.

BestLink SNMP/WEB Adapter User’s Guide : LTM-1343 B Draft 10/03/2001

1

Image 7
Contents Bestlink SNMP/WEB Adapter Class a EMC Statements Requesting a Declaration of ConformityFCC Part EN50091-2 Page Page Table of Contents Appendix Introduction System Application BestLink SNMP/WEB Adapter System Application DiagramInstalling the Internal BestLink Adapter InstallationInstalling the Internal BestLink Adapter Installing the External BestLink AdapterInstalling the External BestLink Adapter Configuring the Adapter Locally ConfigurationConfiguring the Adapter Remotely Before You Start Local ConfigurationCable Connection with External BestLink Adapter Connecting the BestLink SNMP/WEB AdapterBestLink SNMP/WEB Adapter Main Menu Screen SNMP/WEB Adapter Settings Screen Configuring the AdapterExiting the Configuration Program Set the IP Address, Gateway Address and MIB System Group Set Write Access ManagersSet SNMP/WEB Card Control Group UPS Event Actions Set UPS InformationSet Trap Receivers Set IP Addresses of Primary and Secondary Date ServerMail Notification Set Superuser Name and PasswordBack to Main Menu Add a Routing Condition in the PC Remote ConfigurationRoute add 192.168.7.18 BestLink Adapter Home Running the Web BrowserSetup Network Configuration Remote Configuration UPS Management from a Web Browser UPS Power ManagementBecoming a Superuser Forcing the UPS to Shut Down Turning the UPS On and OffMail Notification Configuring E-mail NotificationPlanning a Scheduled UPS Shutdown and Restart UPS Shutdown ScheduleScheduling a UPS Battery Test Performing a Manual UPS Battery TestSelect Battery Test Schedule Viewing the UPS History Logs UPS Management from an Snmp NMSViewing the UPS Status with CheckUPS-like Applet Receiving Event Traps Viewing UPS Monitoring ParametersAutomatic Shutdown of UPS-Protected Computers UPS Power Management Appendix Technical SpecificationsExternal BestLink Adapter Rear Panel Adapter ComponentsLED Definitions DIP Switch DescriptionDIP Switch Modes LED DescriptionPin Assignments External BestLink Adapter to UPS Serial Connection Serial Cable DefinitionExternal BestLink Adapter to PC Serial Connection Upgrading the BestLink Adapter Firmware 852-2830-3030 Service and SupportExtended Service Coverage Two-Year Limited Warranty US and Canada OnlyForce Majeure International Limited WarrantyAppendix Page LTM-1343 B