7. User operations

The UPS has a four-button graphical LCD with backlight. It provides useful information about the unit itself, load status, events, measurements, and settings.

The LCD backlight is switched on by pressing any button. It has a timeout that automatically switches off after 15 minutes of inactivity.

Display functions

As default and after 15 minutes of inactivity the UPS is showing the selectable start screen:

1.Logo screen

2.Mimic screen (See User Settings on LCD screen)

The screen backlit has automatic shutdown after long period of inactivity. It will light up once a button is pushed. The right side button will initiate the text to the screen. The scrolling through the menu structure is done with buttons indicated by the ↑ ↓images of the LCD screen. The menu structure is shown in the table below.

Main Menu

Submenu

Menu functions

I

 

 

 

 

UPS off / System normal / UPS supporting load / UPS on battery /

UPS STATUS

->

UPS on bypass / +active alarms and notices / +battery status

 

 

(resting, charging, floating, not connected, dischargin)

I

 

 

EVENT LOG

->

Notice / Alarm

 

 

 

I

 

 

 

 

 

MEASUREMENTS

OUTPUT

Voltage / Current / Frequency / Power

 

 

 

 

BATTERY

Voltage / Current / Runtime

 

 

 

 

INPUT

Voltage / Current / Frequency

 

 

 

 

BYPASS

Voltage / Frequency

 

 

 

I

 

 

CONTROL

->

Goto bypass / Battery test / Display test

 

 

 

 

USER

Date / LCD contrast / Change language / Relay config / Signal

SETTINGS

inputs / Serial port config / Start screen / User password / Audible

SETTINGS

 

alarms / Battery charging method / +list of std. settings

 

 

 

SERVICE

Adjust parameters / Adjust events / Reset custom / Clear history /

 

SETTINGS

+ modem call settings

I

 

 

IDENTIFICATI-

->

UPS Type / Part nro. / Serial nro / Revisions

ON

 

 

I

 

 

TURN UPS

->

-

ON/OFF

 

 

Table 38. Menu map for display functions.

32

UPS 8 – 15 kVA, 230V 50/60 Hz output

1022403

 

User’s Guide

Revision B1

Image 32
Contents Page Copyright Contents Safety instructions User precautionsAudience CE markingEnvironment InquiriesUnpacking and visual inspection Mechanical installationDelivery check Type designation label Planning before installation Equipment Weight Point DistributedCabinet installation Mechanical bypass switchMechanical bypass switch MBS when installed in the backside Transformer option External battery cabinet option Battery racksElectrical installation Location of the power terminalsPower cables and protective fuses Power terminals found in UPS unitsWiring procedure Installation procedureWiring diagram of UPS N-model 3-ph rectifier Wiring diagram of UPS NT-model 3-ph rectifier Wiring diagram of UPS S-model 1-ph rectifier Wiring diagram of UPS ST-model 1-ph rectifier Wiring diagram of UPS S-model 1-ph rectifier, Norway External Battery Cabinet EBC installation procedure Do not place EBC on the UPS unitUser Settings Number of Battery Strings SPM tie cabinet Dimensions of the SPM SPM9155 wiring diagram with three UPSs connected Connection to the standard RS-232 port Software and connectivityCommunication cables External control connections LanSafe softwareEmergency Power Off EPO External control cable connections to the UPSProgrammable signal inputs Relay outputsSlot communication option SNMP/Web Module optionalModus/Jbus Module optional AS400 Relay Module optionalSingle Serial Port Module optional User operations Display functionsUser Settings Description Available settings Default setting GeneralConfiguring user settings Using relay outputsChanging language Changing charging currentBattery start-up Normal start-upShutdown CheckMaintenance Regular service/intervalsScrapping BatteriesCooling fan LED IndicatorsMaintenance bypass switch MBS operation Turn UPS from normal mode to mechanical bypass No break transfer from normal mode to Service BypassTurn UPS from mechanical bypass to normal mode No break transfer from Mechanical Bypass to normal modeTurn on S3 switch to connect UPS output to load Dimensional drawings UPS models with no battery sectionsExternal battery cabinet models with 2 and 3 sections Technical data Mechanical configurationCharacteristics StandardsAC output AC inputDC circuit Warranty

8 - 15 kVA, 8 - 10 kVA specifications

Powerware 8 - 10 kVA and 8 - 15 kVA are robust uninterruptible power supply (UPS) systems designed to provide reliable power protection and enhanced performance for critical applications. These UPS systems are ideal for various business environments, including data centers, server rooms, and industrial settings.

A primary feature of the Powerware series is its modular design, which allows for easy scalability and adaptability to meet the growing power requirements of modern IT infrastructure. The systems can be configured to provide redundancy, ensuring increased reliability and uptime while delivering high-efficiency performance.

One of the standout characteristics of the Powerware 8 - 10 kVA and 8 - 15 kVA models is their advanced double-conversion technology, which offers consistent power conditioning and isolation from utility issues like voltage surges, frequency variations, and power outages. This technology ensures that connected devices receive clean, stable power, minimizing the risk of downtime caused by electrical disturbances.

Another key feature is the availability of an intuitive LCD display that provides users with real-time information about the UPS status, critical alarms, and event logs, enabling proactive management of power demands and potential issues. The systems also support remote monitoring and management through advanced communication options, allowing IT administrators to maintain oversight of the power environment from any location.

The Powerware series incorporates high-efficiency designs that help reduce energy consumption, ultimately lowering operational costs. With an input power factor of up to 0.99 and a typical efficiency exceeding 94%, these UPS units not only contribute to environmental sustainability but also enhance the overall performance of the power infrastructure.

In addition to these practical features, the Powerware 8 - 10 kVA and 8 - 15 kVA models are equipped with multiple output options, including configurable outlets and hardwire connections, offering flexibility in deployment. They also come with advanced battery management systems, which optimize battery performance, extending their lifespan and reducing maintenance efforts.

Overall, Powerware 8 - 10 kVA and 8 - 15 kVA systems are reliable choices for businesses seeking efficient and adaptable power protection solutions to support their critical operations. Their innovative technologies and comprehensive features ensure that companies can maintain productivity while safeguarding their valuable equipment and data against power disruptions.