10. Technical data

Standards

UPS

8 kVA

 

10 kVA

 

12 kVA

 

15 kVA

Safety

 

IEC 62040-1-1, EN 62040-1-1 and EN 60950

 

 

 

 

 

 

 

 

 

EMC

 

 

 

EN 50091-2

 

 

 

 

 

 

 

 

Product

 

 

IEC 62040-3 and EN 62040-3

 

 

 

 

 

 

 

 

 

Environment

UPS

8 kVA

 

10 kVA

12 kVA

 

15 kVA

Amb. temperature

 

0 to +40°C (electronics), 15 to +25°C (batteries)

 

 

 

 

 

 

 

 

Relative humidity

 

 

0 to 95%, no condensation allowed

 

 

 

 

 

 

 

 

Altitude

 

 

<1000 m above sea level at +40°C

 

 

 

 

 

 

Vibration

IEC 68-2-6; max. 0.3 mm (2 to 9 Hz), max. 1 m/s2 (9 to 200 Hz) sinusoidal

 

 

 

 

 

 

 

Mechanical configuration

UPS

 

8 kVA

 

10 kVA

 

12 kVA

 

15 kVA

Dimensions

 

 

 

 

 

 

 

 

 

- Width

 

 

 

 

 

305 mm

 

 

- Depth

 

 

 

 

 

702 mm

 

 

- Height

 

 

 

817 mm (32 bat) or 1214 mm (2x32 bat)

Weight

 

 

 

 

 

 

 

 

 

- no battery

 

 

 

65 kg

 

 

70 kg

- 32 battery

 

 

 

155 kg

 

 

160 kg

- 64 battery

 

 

 

265 kg

 

 

270 kg

- 32 battery and transformer

 

 

270 kg

 

 

275 kg

- MBS

 

 

 

 

 

+15 kg

 

 

Colour

 

 

 

 

RAL 9005 black

 

 

Characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPS

8 kVA

 

10 kVA

 

12 kVA

 

15 kVA

Efficiency

Up to 92%

 

Up to 93%

 

Up to 92%

 

Up to 93%

- nominal load

 

 

 

 

 

 

 

 

 

 

 

 

Heat losses

<580 W

 

<720 W

 

<870 W

 

<1050 W

 

 

 

 

 

 

 

Backup time

10 min (32 bat 7 Ah)

6 min (32 bat 7 Ah)

 

 

 

 

15 min (32 bat 9 Ah)

10 min (32 bat 9 Ah)

8 min (32 bat 9 Ah)

5 min (32 bat 9 Ah)

- load pf 0.7

28 min (64 bat 7 Ah)

20 min (64 bat 7 Ah)

15 min (64 bat 7 Ah)

10 min (64 bat 7 Ah)

(+25°C amb.)

33 min (64 bat 9 Ah)

25 min (64 bat 9 Ah)

20 min (64 bat 9 Ah)

15 min (64 bat 9 Ah)

 

Noise (ISO 7779)

 

 

 

50 - 53 dB(A) depending on the load

 

 

1022403

UPS 8 – 15 kVA, 230V 50/60 Hz output

43

Revision B1

User’s Guide

 

Image 43
Contents Page Copyright Contents CE marking Safety instructionsUser precautions AudienceInquiries EnvironmentDelivery check Mechanical installationUnpacking and visual inspection Type designation label Equipment Weight Point Distributed Planning before installationMechanical bypass switch Cabinet installationMechanical bypass switch MBS when installed in the backside Transformer option Battery racks External battery cabinet optionLocation of the power terminals Electrical installationPower terminals found in UPS units Power cables and protective fusesInstallation procedure Wiring procedureWiring diagram of UPS N-model 3-ph rectifier Wiring diagram of UPS NT-model 3-ph rectifier Wiring diagram of UPS S-model 1-ph rectifier Wiring diagram of UPS ST-model 1-ph rectifier Wiring diagram of UPS S-model 1-ph rectifier, Norway Do not place EBC on the UPS unit External Battery Cabinet EBC installation procedureUser Settings Number of Battery Strings SPM tie cabinet Dimensions of the SPM SPM9155 wiring diagram with three UPSs connected Communication cables Software and connectivityConnection to the standard RS-232 port LanSafe software External control connectionsExternal control cable connections to the UPS Emergency Power Off EPORelay outputs Programmable signal inputsSNMP/Web Module optional Slot communication optionSingle Serial Port Module optional AS400 Relay Module optionalModus/Jbus Module optional Display functions User operationsDescription Available settings Default setting General User SettingsChanging charging current Configuring user settingsUsing relay outputs Changing languageCheck Battery start-upNormal start-up ShutdownBatteries MaintenanceRegular service/intervals ScrappingMaintenance bypass switch MBS operation LED IndicatorsCooling fan No break transfer from normal mode to Service Bypass Turn UPS from normal mode to mechanical bypassNo break transfer from Mechanical Bypass to normal mode Turn UPS from mechanical bypass to normal modeTurn on S3 switch to connect UPS output to load UPS models with no battery sections Dimensional drawingsExternal battery cabinet models with 2 and 3 sections Standards Technical dataMechanical configuration CharacteristicsDC circuit AC inputAC output Warranty

8 - 15 kVA, 8 - 10 kVA specifications

Powerware 8 - 10 kVA and 8 - 15 kVA are robust uninterruptible power supply (UPS) systems designed to provide reliable power protection and enhanced performance for critical applications. These UPS systems are ideal for various business environments, including data centers, server rooms, and industrial settings.

A primary feature of the Powerware series is its modular design, which allows for easy scalability and adaptability to meet the growing power requirements of modern IT infrastructure. The systems can be configured to provide redundancy, ensuring increased reliability and uptime while delivering high-efficiency performance.

One of the standout characteristics of the Powerware 8 - 10 kVA and 8 - 15 kVA models is their advanced double-conversion technology, which offers consistent power conditioning and isolation from utility issues like voltage surges, frequency variations, and power outages. This technology ensures that connected devices receive clean, stable power, minimizing the risk of downtime caused by electrical disturbances.

Another key feature is the availability of an intuitive LCD display that provides users with real-time information about the UPS status, critical alarms, and event logs, enabling proactive management of power demands and potential issues. The systems also support remote monitoring and management through advanced communication options, allowing IT administrators to maintain oversight of the power environment from any location.

The Powerware series incorporates high-efficiency designs that help reduce energy consumption, ultimately lowering operational costs. With an input power factor of up to 0.99 and a typical efficiency exceeding 94%, these UPS units not only contribute to environmental sustainability but also enhance the overall performance of the power infrastructure.

In addition to these practical features, the Powerware 8 - 10 kVA and 8 - 15 kVA models are equipped with multiple output options, including configurable outlets and hardwire connections, offering flexibility in deployment. They also come with advanced battery management systems, which optimize battery performance, extending their lifespan and reducing maintenance efforts.

Overall, Powerware 8 - 10 kVA and 8 - 15 kVA systems are reliable choices for businesses seeking efficient and adaptable power protection solutions to support their critical operations. Their innovative technologies and comprehensive features ensure that companies can maintain productivity while safeguarding their valuable equipment and data against power disruptions.