Powerware 9315 UPS operation manual 7shows the Unit Statistics screen

Page 35

Using the Monitor Panel

Select Unit from the Statistics menu to display a listing of statistics about UPS operation.

Figure 5-7shows the Unit Statistics screen.

 

 

Uninterruptible Power System

 

 

UPS System Normal

 

 

 

04 NOV 1997

14:23:45

Alarm:

None

 

 

 

 

 

 

 

Notice: None

 

 

 

 

 

 

 

Battery

 

Start Date:

 

04 MAY 1997

 

Percent

 

 

 

 

 

 

 

100%

Number of Incidents: Month Total Time On: DAYS HR MN

 

 

 

 

On Battery < 1

Min.

0

0

UPS

0035 20 59

 

 

On Battery 1−4 Min.

1

0

Bypass

0000 00 30

 

 

On Battery > 4 Min.

0

0

Battery

0000 00 02

 

 

Full Batt. Discharge

0

0

Generator 0000 00 00

Statistics

Building Alarm

1

2

11

Logic

0035 21 30

Building Alarm

2

2

9

 

 

 

 

 

Building Alarm

3

3

8

 

 

 

Unit

 

Building Alarm

4

2

5

Availability

 

 

Building Alarm

5

3

8

UPS

 

0.99

 

 

 

 

 

Building Alarm

6

3

9

Bypass

 

0.81

Meters

Events

Statistics Graphics

Setup

 

 

 

 

 

Figure 5-7. Unit Statistics Screen

The left column shows the number of UPS incidents for the current month and total from the start date shown at the top of the screen. The top right column shows the time that the UPS was on bypass, battery, or generator, and the amount of time the UPS logic has been functioning since the start date. The lower right column shows the percent of availability of the UPS and the bypass source.

EATON Powerware® 9315 UPS (200–300 kVA) Operation Manual S 164201036 Rev G www.powerware.com

5−9

Image 35
Contents Page Class a EMC Statements Consignes de sécuritéTable of Contents Starting and Stopping the UPS Product Specifications −1 10 Responding to System Events −1 List of Figures Conventions Used in This Manual IntroductionGetting Help For More InformationGetting Started Safety WarningsTypical Powerware 9315 UPS System Looking Inside the UPS Power Processing Unit PPUCommunication Bays UPS Standard FeaturesMonitor Panel Control PanelOptions and Accessories Relay Interface Module Power Distribution Module LV models onlyUpgrade Capability Remote Monitor PanelCustomer Convenience Outlet Output TransformerModem Symbols, Controls, and Indicators Understanding UPS Operation Normal ModeCB1 Bypass Mode Battery Mode Monitoring and Controlling UPS Operation This page intentionally left blank Starting and Stopping the UPS Using the Control PanelTo Place the UPS in Normal Mode To Start the UPS in Bypass Mode To Shut Down the UPS from Normal ModeThis page intentionally left blank Using the Monitor Panel System Normal 04 MAY 142345 Alarm Using the LCD ScreenUsing the Load Off Button Using the ButtonsAdjusting the Contrast Using the Menu Options Reading the Status Indicators4shows the Load Amps Meters screen Load Amps Meters Screen 5shows the Event History Log screen 6shows the Active System Events screen 7shows the Unit Statistics screen 8shows the Mimic screen −11 −12 Building Alarm Monitoring Using Features and OptionsSummary Alarm Contacts Remote Monitor Panel System Normal External Battery Disconnect Battery CabinetsUPS Available Relay Interface ModuleOn Generator Supervisory Contact ModuleThis page intentionally left blank Locating the Communication Bays CommunicationX−Slot Cards Location of Communication Bays on the UPS Powerware 9315Connecting Equipment to a Serial Port LanSafe Power Management SoftwarePin Assignments for Port 1 DB-9 Pin Assignments for Port 2 DB-25 Configuring the Serial Ports Rate ModeSave Default SettingsData/Stop HandshakingPrinting Selected Information Terminal ModeEvent History Log Entire Log Ctrl+PSystem Meters Meters Printout Ctrl+MSystem Information Printout Ctrl+A Battery Test Printout Ctrl+BProgram Building Alarms System ConfigurationSystem Configuration Mode Main Menu Enable/Disable Default Functions Customize Alarm Messages Program Unit Name Adjust Output VoltageChange Password WK DAY MON Hrmn Battery Test SetupModify Low Battery Time Calibration ModeComputer Mode Remote Monitor ModeRemote Notification −20 Maintaining the UPS System Important Safety InstructionsE R T I S S E M E N T Performing Preventive MaintenanceMaintenance Training This page intentionally left blank Current Product SpecificationsSystem Output Rectifier/Charger Capacity Nominal Battery This page intentionally left blank System Event Messages Responding to System EventsSystem Event Horns System Event LightsResponding to System Events Rectifier Messages − Alarms Rectifier Messages − Notices Monitor Panel Alarms Monitor Panel Notices Using the Load OFF Button Resetting the UPS System after Load Off Warranty Warranty Page 164201036G