SUPER MICRO Computer 6026TT-GTRF Rack Mounting Considerations, Ambient Operating Temperature

Page 19

Chapter 2: Server Installation

Allow the hot plug SATA drives and power supply modules to cool before touch- ing them.

Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling.

Make sure all power and data cables are properly connected and not blocking the chassis airflow. See Chapter 5 for details on cable connections.

Rack Mounting Considerations

Ambient Operating Temperature

If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra).

Reduced Airflow

Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised.

Mechanical Loading

Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.

Circuit Overloading

Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

Reliable Ground

A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connec- tions other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).

2-3

Image 19
Contents Super Manual Revision Release Date November 16 About This Manual PrefaceManual Organization Bios System SafetyAdvanced Serverboard Setup Advanced Chassis SetupPreface Table of Contents System Interface Appendix a Bios Error Beep Codes Overview Chapter IntroductionPCI Expansion Slots Serverboard FeaturesProcessors Memory Serial ATAInfiniBand Other FeaturesOnboard Controllers/Ports Graphics ControllerIntel 5520 Chipset System Block Diagram Server Chassis Features Sata Backplane/Drives 2U Twin System NotesGPU Subsystem NodesAsia-Pacific Contacting SupermicroHeadquarters EuropePage Preparing for Setup Chapter Server InstallationUnpacking the System Choosing a Setup Location Rack Mounting Considerations Ambient Operating TemperatureRemoving the Protective Film Removing the Protective FilmSeparating the Inner and Outer Rails Rail AssemblyRack Mounting Instructions Separating the Sections of the Rack RailsInstalling the Inner Rails Installing the Inner Rail ExtensionsOuter Rack Rails Installing the Outer Rails to the RackInstalling the Chassis into a Rack Installing Into the RackAccessing the Inside of a Node Figure Checking the Serverboard SetupChecking the Components and Setup Checking the Airflow Preparing to Power OnProviding Power Checking the Sata drivesRemoving a Node from the System Page Chapter System Interface PowerControl Panel Buttons Sata Drive Carrier LEDs Control Panel LEDsOverheat/Fan Fail Electrical Safety Precautions Chapter System SafetyGeneral Safety Precautions ESD Precautions Installing the Onboard Battery Operating PrecautionsHandling the Serverboard Chapter Advanced Serverboard SetupI/O Ports I/O PortsInstalling LGA1366 Processors Processor and Heatsink InstallationCPU Installing a CPU Heatsink Removing the Heatsink Installing Memory Modules Installing MemoryMemory Support Front View Dimm Installation NotchAdding PCI Cards PCI Card InstallationPCI Express Slot LE2 Serverboard DetailsServerboard Quick Reference Connector DescriptionJumper Description Internal Buzzer Connector DefinitionsFront Panel Accessible Add-on Card Header JF2 NMI HeaderFan Header Video ConnectorUniversal Serial Bus USB InfiniBand Connection X8DTT-HIBXF+/ HIBQF+ Ethernet PortsUnit Identifier Switches System ResetSerial Ports Cmos Clear Jumper SettingsTo Clear Cmos Watch Dog Enable/Disable LAN1/LAN2 Enable/DisableVGA Enable/Disable LAN1/LAN2 LEDs Onboard IndicatorsInfiniBand LED Indicators LEB1/LEB2 Onboard Power LEDSerial ATA Connections Serial ATA PortsBMC Activity LED LE2 Rear UID LED LE4Installing Additional Drivers 12 Configuring Supero Doctor Page Chapter Advanced Chassis Setup System Fans Control PanelSystem Fan Failure Fan ConfigurationChanging a System Fan Overview Hard Drive Installation/RemovalInstalling and Removing Hard Drives Installing a Hard Drive into the Drive CarrierRemoving a Dummy Drive Tray Installing/Removing Hot-swap DrivesNode a Node B Removing a Node Node Installation/RemovalRemoving a System Node Removing/Replacing the Power Supply Figure Installing the Air ShroudsPower Supply Installing an Air ShroudRemoving the Power Supply Release Tab Introduction Starting Bios Setup UtilityHow To Change the Configuration Data ChapterSystem Time/System Date Main SetupStarting the Setup Utility System OverviewCPU Type Bios Build DateAMI Bios Core Version ProcessorXboot Features Advanced Setup ConfigurationsXProcessor and Clock Options XPower ConfigurationIntel Eist Technology Hardware Prefetcher Available when supported by the CPUC1E Support Active Processor CoresXcpu Bridge Configuration XAdvanced Chipset ControlMemory Frequency Memory ModeMemory ECC Error Threshold QPI L0s and L1Temperature Rise Hysteresis TemperatureGuardband Temperature Inlet TemperatureXSouthBridge Configuration XNorth Bridge ConfigurationXIDE/SATA Configuration Type LBA/Large ModePIO Mode SATA#2 ConfigurationDMA Mode XPCI/PnP Configuration XSuper IO Device Configuration XRemote Access ConfigurationTerminal Type Sredir Memory Display DelayCPU Overheat Alarm XHardware Health MonitorCPU Temperature CPU Temperature/System TemperatureFan1 ~ Fan 4 Reading Acpi Version Features Acpi Apic SupportXacpi Configuration Fan Speed Control MonitorXipmi Configuration X8DTT-HF/-HIBXF/-HIBQF Only XGeneral Whea ConfigurationParameter Selector XView BMC System Event LogXSet LAN Configuration XIP Address ConfigurationXSubnet Mask Configuration Xmac Address ConfigurationGateway Address XGateway Address ConfigurationSubnet Mask Current Subnet Mask in BMCXdmi Event Log Security SettingsBoot Sector Virus Protection Boot ConfigurationXBoot Device Priority Password CheckXRemovable Drives XHard Disk DrivesXCD/DVD Drives Exit Options Bios RecoveryBoot Sector Recovery from a USB Device How to Recover the Amibios Image the Main Bios BlockHow to use Serial Flash for Boot Sector Recovery Boot Sector Recovery from a Serial Port Serial FlashPage Page Bios Error Beep Codes Appendix a Bios Error Beep CodesBios Error Beep Codes Page Installing Windows for a RAID System Appendix B Installing WindowsInstalling Windows for a Non-RAID System Appendix C System Specifications BiosChassis Regulatory Compliance